• Title/Summary/Keyword: passive sampling

Search Result 109, Processing Time 0.034 seconds

Multichannel Analysis of Surface Waves (MASW) Active and Passive Methods

  • Park, Choon-Byong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.17-22
    • /
    • 2006
  • Shear modulus is directly linked to material's stiffness and is one of the most critical engineering parameters. Seismically, shear-wave velocity (Vs) is its best indicator. Although methods like refraction, down-hole, and cross-hole shear-wave surveys can be used, they are generally known to be tougher than any other seismic methods in field operation, data analysis, and overall cost. On the other hand, surface waves, commonly known as ground roll, are always generated in all seismic surveys with the strongest energy, and their propagation velocities are mainly determined by Vs of the medium. Furthermore, sampling depth of a particular frequency component of surface waves is in direct proportion to its wavelength and this property makes the surface wave velocity frequency dependent, i.e., dispersive. The multichannel analysis of surface waves (MASW) method tries to utilize this dispersion property of surface waves for the purpose of Vs profiling in 1-D (depth) or 2-D (depth and surface location) format. The active MASW method generates surface waves actively by using an impact source like sledgehammer, whereas the passive method utilizes those generated passively by cultural (e.g., traffic) or natural (e.g., thunder and tidal motion) activities. Investigation depth is usually shallower than 30 m with the active method, whereas it can reach a few hundred meters with the passive method. Overall procedures with both methods are briefly described.

  • PDF

A Study on the Characteristics of Ambient Volatile Organic Compounds in Gimhae (김해 지역 대기 중 휘발성유기화합물 특성연구)

  • Bong, Sang-Hun;Jeong, Seong-Wook;Park, Heung-Jai;Kim, Woo-Seong;Kim, Sung-Hun
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.871-878
    • /
    • 2008
  • In this study, we measured volatile organic compounds in Gimhae city, South Korea. We selected twenty site and measured volatile organic compounds in ambient air by passive sampler when at sampling intervals of two month from April to December 2005. Passive sampler was exposed for fifteen day in ambient air. And samples were analyzed by GC/FID for volatile organic compounds. The results of each measured functional zone, mean concentration of each compound measured were generally higher the industrial complex area and traffic pollution area than residental area. Each area showed similar pattern for the observation period. concentration of measured each compound were the following order: winter > fall > spring > summer.

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS

  • Kim, Hyo-Cherl;Paik, Nam-Won;Kim, Kyoung-Ran;Kim, Kyoung-Su;Lee, Kyoung-Suk;Cho, Kyung-Ah
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.371-372
    • /
    • 2005
  • Active sampler has been widely used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. The result of these tests that indicated that passive sampler can be used instead of active sampler in ETS, because coefficient of determination was 0.9292 between active and passive sampling in smoking area

  • PDF

Study of equivalent circuit modeling for microstrip structure using passive component (수동소자를 이용한 마이크로스트립 구조의 등가회로 모델링에 관한 연구)

  • Paek, Hyun;Kim, Kun-Tae;Kwon, So-Hyun;Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1434-1435
    • /
    • 2008
  • In this paper, we propose a method that applies Vector Fitting(VF) and Adaptive Frequency Sampling(ASF) technique to the equivalent circuit model for RF passive components. VF and ASF schemes are implemented to obtain the rational functions. S parameters of the equivalent circuit model is compared to those of EM simulation in case of the microstrip structure with coupled bandpass filter.

  • PDF

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Suntae
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

월성 원전 주딘의 대기중 $^l4C$ 포집기술

  • 강덕원;김언희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.671-676
    • /
    • 1998
  • 방사성 $\beta$핵종 중의 하나인 $^{14}$ C은 중수로에서 상대적으로 많이 방출된다. 본 연구에서는 국내 유일의 중수로 원전인 월성 원자력발전소에서 배기구를 통해 환경으로 방출된 $^{14}$ C을 감시하기 위한 두 가지 타입의 대기시료 포집기술을 개발하였다. 하나는 전원을 이용하는 능동시료포집법(active air sampling)이며, 다른 하나는 전원을 사용하지 않는 수동시료포집법(passive air sampling)이다. 시료분석의 재현성 측면에서는 능동시료포집법이 보다 나은 것으로 알려져 있으나 시료채취 장소의 제한성 등으로 인해 최근에 들어와 수동시료포집법의 사용을 선호하고 있다. 본 연구를 통해 두가지 시료 채취법에 대한 측정오차의 신뢰성을 검증하기 위해 동위원소 분별효과를 비교 평가해 본 결과, 측정상의 오차가 약 2% 정도로 나타나 시료채취가 간단한 수동시료포집법의 사용타당성 및 활용 가능성을 입증하였다.

  • PDF

On the Design Method of a Haptic Interface Controller with Virtual Coupling

  • Kim, Keehoon;W.K. Chung;Y. Youm
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.25.5-25
    • /
    • 2001
  • A haptic interface can be a passive system with virtual coupling as a filter virtual coupling has been designed for satisfying passivity. However, it affects transparency of haptic interface as well as stability. This paper suggests new design criterion of a haptic interface controller by considering transparency. As a result, sampling time and the range of impedance or admittance should be considered as well as virtual coupling for desired performance of hapticdisplay. And experiments show that the suggested design criterion can be applied successfully for desired performance.

  • PDF

Efficient Target Tracking with Adaptive Resource Management using a Passive Sensor (수동센서를 이용한 효율적인 표적추적을 위한 적응적 자원관리 알고리듬 연구)

  • Kim, Woo Chan;Lee, Haeho;Ahn, Myonghwan;Lee, Bum Jik;Song, Taek Lyul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.7
    • /
    • pp.536-542
    • /
    • 2016
  • To enhance tracking efficiency, a target-tracking filter with a resource management algorithm is required. One of the resource management algorithms chooses or evaluates the proper sampling time using cost functions which are related to the target tracking filter. We propose a resource management algorithm for bearing only tracking environments. Since the tracking performance depends on the system observability, the bearing-only tracking is one of challenging target-tracking fields. The proposed algorithm provides the adaptive sampling time using the variation rate of the error covariance matrix from the target-tracking filter. The simulation verifies the efficiency performance of the proposed algorithm.

Smoke Density and Operation of Fire Detector Influenced by Air Stream (기류순환이 연기농도와 감지기 작동에 미치는 영향)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.28-32
    • /
    • 2002
  • The performance based design in fire detection system, the effect of high airflow and dilution of smoke produced in any fire situation serve to increase the response time of point-type smoke detectors. This study investigated the smoke density of ceiling, under the air stream and in normal status when fire type is smoldering fires. The result of study, smoke generated in the fire was swept away from nearby spot type smoke detector which failed to actuate because dispersed in diluted form around the room. The concept of performance based design in fire detection system of protected area influenced by high airflow provided the need of active fire detection system such as air sampling smoke detection system.