• 제목/요약/키워드: passive ranging

검색결과 60건 처리시간 0.043초

수중 소음제어 기술의 최근 연구동향 (Recent Developments in Underwater Noise Control Technology)

  • 엄원석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.381-381
    • /
    • 2012
  • Noise control in underwater environments is an entirely different beast from its airborne counterpart, partly because of the orders-of-magnitude difference in density and compressibility between water and air. One of the most popular systems ever used for (passive) noise reduction under water is an anechoic coating known as "alberich," which was developed by the German during the Second World War and are still used today in naval applications. This talk looks back on some recent developments in underwater noise control, ranging from acoustic metamaterials to active noise control techniques, specifically geared to achieving underwater invisibility.

  • PDF

ATM-PON의 ONU에서 상향 셀 전송을 위한 승인처리기의 구현 (Implementation of a Grant Processor for Upstream Cell Transmission at the ONU in the ATM-PON)

  • 우만식;정해;유건일
    • 한국통신학회논문지
    • /
    • 제27권5C호
    • /
    • pp.454-464
    • /
    • 2002
  • ATM PON (Passive Optical Network) 시스템은 OLT (Optical Line Termination)와 다수의 ONU (Optical Network Unit), 그리고 스플리터와 함께 PON을 구성하는 광케이블로 구성된다. 상향 전송에서 셀 충돌을 피하기 위하여, 새로운 ONU가 설치될 때 ranging이라는 정교한 절차를 필요로 한다. 이 절차가 종료된 후에 ONU는 OLT가 제공하는 승인에 따라 상향 셀을 전송할 수 있다. 여러 가지 요인의 변화에 의해 발생할 수 있는 셀 충돌을 예방하기 위하여, OLT는 지속적으로 셀 위상 감시를 수행해야 한다. 이는 OLT가 모든 상향 셀에 대하여 기대되는 도착 시점을 예측하고, 실제 도착하는 시점을 감시하여, 두 시점 간의 오차를 계산하는 것을 의미한다. 따라서, OLT의 TC (Transmission Convergence) 칩에는 현재 제공하는 승인에 대한 셀의 도착할 시점을 계산할 수 있는 예측기가 필요하다. 본 논문에서는 이러한 예측기를 등화 왕복지연에 해당하는 길이를 갖는 이동 레지스터를 이용하여 구현한다. 하나의 레지스터는 8 비트로 구성되어, OLT는 어떤 ONU가 어떤 종류의 셀을 보내는지 확인 할 수 있다. 또한 TC 칩은 예측기의 기능을 이용하여 ONU의 유효 대역폭을 계산할 수 있다. 타임 시뮬레이션과 구현된 광 보드를 측정하여, 예측기의 동작을 확인한다.

Rubus croceacanthus Leveille inhibits mast cell-mediated immediate-type allergic reactions and tumor necrosis factor-$\alpha$ secretion

  • Moon, Phil-Dong;Park, In-Young;Na, Ho-Jeong;Hong, Seung-Heon;Kim, Hyung-Min
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2003년도 Annual Meeting of KSAP : International Symposium on Pharmaceutical and Biomedical Sciences on Obesity
    • /
    • pp.99-99
    • /
    • 2003
  • We studied the effect of Rubus croceacanthus Leveille (RCL) on mast cell-mediated anaphylactic reactions. RCL inhibited compound 48/80-induced systemic anaphylactic shock. When RCL was given at concentrations ranging from 0.01 to 1 mg/$m\ell$, the histamine release from rat peritoneal mast cells induced by compound 48/80 was reduced in a dose-dependent manner. RCL also inhibited passive cutaneous anaphylaxis activated by anti-dinitrophenyl IgE. In addition, RCL inhibited phorbol 12-myristate 13-acetate and A23187-induced tumor necrosis factor-${\alpha}$ secretion from human mast cell line HMC-1 cells. These results indicate that RCL may possess a strong anti-anaphylactic activity.

  • PDF

OPNET을 이용한 Ethernet-PON 시스템 구현 및 성능 평가 (Implementation and Performance Evaluation of Ethernet-PON System using OPNET)

  • 안계현;한경은;박혁규;노선식;김영천
    • 한국통신학회논문지
    • /
    • 제28권5B호
    • /
    • pp.466-474
    • /
    • 2003
  • 본 논문에서는 최근 효율적이고 경제적인 초고속 광가입자망 기술로서 부각된 Ethernet-PON 시스템을 위한 시뮬레이션 모델을 OPNET을 이용하여 구현한다. 설계한 Ethernet-PON 시스템은 IEEE 802.3ah EFM을 기반으로 요청/허가 TDMA MAC 프로토콜을 사용하며 제어 패킷들의 교환을 통해 등록, 레인징, 동적 대역 할당 등의 기능을 수행한다. 시뮬레이션 모델을 사용하여 초기 등록 절차에서의 성공률과 나중 등록을 위한 지연에 관한 결과를 분석하였다. 또한 사용자의 요구 대역 정보를 기반으로 대역을 동적으로 할당하는 Dynamic TDMA 프로토콜과 사용자의 요구에 관계없이 동등한 대역을 할당하는 Static TDMA 프로토콜의 성능을 채널 이용률 및 큐잉 지연 관점에서 비교하였다. 본 논문에서 구현한 시뮬레이터는 Ethernet-PON 시스템의 설계 과정에서 논의될 수 있는 여러 기술 사항들에 대한 적절한 선택 기준을 모의 실험을 통해 제시할 수 있을 것으로 기대된다.

Cyclic testing of a new visco-plastic damper subjected to harmonic and quasi-static loading

  • Modhej, Ahmad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.317-333
    • /
    • 2022
  • Visco-Plastic Damper (VPD) as a passive energy dissipation device with dual behavior has been recently numerically studied. It consists of two bent steel plates and segments with a viscoelastic solid material in between, combining and improving characteristics of both displacement-dependent and velocity-dependent devices. In order to trust the performance of VPD, for the 1st time this paper experimentally investigates prototype damper behavior under a wide range of frequency and amplitude of dynamic loading. A high-axial damping rubber is innovatively proposed as the viscoelastic layer designed to withstand large axial strains and dissipate energy accordingly. Test results confirmed all assumptions about VPD. The behavior of VPD subjected to low levels of excitation is elastic while with increasing levels of excitation, a significant source of energy dissipation is provided through the yielding of the steel elements in addition to the viscoelastic energy dissipation. The results showed energy dissipation of 99.35 kN.m under a dynamic displacement with 14.095 mm amplitude and 0.333 Hz frequency. Lateral displacement at the middle of the device was created with an amplification factor obtained ranging from 2.108 to 3.242 in the rubber block. Therefore, the energy dissipation of viscoelastic material of VPD was calculated 18.6 times that of the ordinary viscoelastic damper.

슬괵근 유연성 평가에 관한 연구 (Comparison of Six Tests for Assessing Hamstring Muscle Length)

  • 김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제5권1호
    • /
    • pp.39-51
    • /
    • 1999
  • Background and Purpose. Objective measurements of hamstring muscle length are needed to quantify baseline limitations and to document the effectiveness of therapeutic interventions. Several indirect clinical tests for measuring hamstring muscle length are available, but influence of their test procedure is not well documented. The purpose of this study were 1) to describe hamstring muscle length as reflected by use of six tests(active straight leg raising(ASLR), passive straight leg raising(PSLR), passive straight leg raising with the lower back flat(PSLRB), active knee extension(AKE), passive knee extension(PKE), hip joint angle(HJA). 2) to examine the correlation among the tests. Subjects, Sixty subjects(30 men. 30 women) ranging in age from 18 to 25 years(mean 20.2 years) and with no limitation hamstring flexibility and no neurological and orthopedical problems. Methods. All subjects performed six tests. A inclinometer was used to determine the end point of range of motion. HJA was measured using an inclinometer placed over the sacrum. PSLRB were tested PSLR with the low back flat and the opposite thigh slightly flexed and support on pillows. Results, A mean ASLR value of 85.9 degrees, PSLR value of 99.9 degrees, PSLRB value of 109.8 degrees, AKE value of 77.2 degrees PKE value of 83.1 degrees and HJA value of 73.0 degrees were obtained for all subjects. A dependent t-test showed significant difference between the angles of ASLR and PSLR(p<0.001). There was a significant difference between the angles of PSLR and PSLRB(p<0.001). There was a significant difference between the angles of AKE and PKE(p<0.001). The highest correlation was between PSLR and PSLRB(r=0.915, p<0.001). All SLR tests were significants related(p<0.001), as well as AKE and PKE(p<0.001). The lowest correlation was between PKE and HJA(r=0.171. p>0.05). Conclusion and Discussion. The results indicated that the hip flexion angles for ASLR, PSLR and PSLRB were a difference, and the knee extension angles for AKE and PKE were a difference.

  • PDF

Corrosion of Steel in Blended Concretes Containing OPC, PFA, GGBS and SF

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn Chu
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.171-176
    • /
    • 2009
  • The chloride threshold level (CTL) in mixed concrete containing, ordinary Portland cement (OPC), pulverized fuel ash (PFA) ground granulated blast furnace slag (GGBS), and silica fume (SF) is important for study on corrosion of reinforced concrete structures. The CTL is defined as a critical content of chloride at the steel depth of the steel which causes the breakdown of the passive film. The criterion of the CTL represented by total chloride content has been used due to convenience and practicality. In order to demonstrate a relationship between the CTL by total chloride content and the CTL by free chloride content, corrosion test and chloride binding capacity test were carried out. In corrosion test, Mortar specimens were cast using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.0, 0.2, 0.4, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder. All specimens were cured 28 days, and then the corrosion rate was measured by the Tafel's extrapolation method. In chloride binding capacity, paste specimens were casting using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.1, 0.2, 0.3, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binders. At 28days, solution mixed with the powder of ground specimens was used to measure binding capacity. All specimens of both experiments were wrapped in polythene film to avoid leaching out of chloride and hydroxyl ions. As a result, the CTL by total chloride content ranged from 0.36-1.44% by weight of binders and the CTL by free chloride content ranged from 0.14-0.96%. Accordingly, the difference was ranging, from 0.22 to 0.48% by weight of binder. The order of difference for binder is OPC > 10% SF > 30% PFA > 60% GGBS.

A Novel Range Estimator for Surface to Air Missile with Closing Velocity Measurements

  • Ra, W.S.;Whang, I.H.;Lee, J.I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1822-1825
    • /
    • 2003
  • A practical range estimator based on the robust Kalman filter is proposed to solve the range estimation problem for surface to air missile(SAM) homing guidance. Apart from the previous works based on the extended Kalman filter(EKF) with bearing only measurement, the proposed scheme makes use of line-of-sight(LOS) rate to ensure the fast convergency at long-range. In this reason, the robust Kalman filter is considered to deal with LOS rate measurement error. The recursive linear structure of proposed filter is easy to implement and make it possible to reduce computational burdens. Moreover, it shows good estimation performance without specific guidance law such as oscillation proportional navigation guidance(OPNG).

  • PDF

The MPI CyberMotion Simulator: A Novel Research Platform to Investigate Human Control Behavior

  • Nieuwenhuizen, Frank M.;Bulthoff, Heinrich H.
    • Journal of Computing Science and Engineering
    • /
    • 제7권2호
    • /
    • pp.122-131
    • /
    • 2013
  • The MPI CyberMotion Simulator provides a unique motion platform, as it features an anthropomorphic robot with a large workspace, combined with an actuated cabin and a linear track for lateral movement. This paper introduces the simulator as a tool for studying human perception, and compares its characteristics to conventional Stewart platforms. Furthermore, an experimental evaluation is presented in which multimodal human control behavior is studied by identifying the visual and vestibular responses of participants in a roll-lateral helicopter hover task. The results show that the simulator motion allows participants to increase tracking performance by changing their control strategy, shifting from reliance on visual error perception to reliance on simulator motion cues. The MPI CyberMotion Simulator has proven to be a state-of-the-art motion simulator for psychophysical research to study humans with various experimental paradigms, ranging from passive perception experiments to active control tasks, such as driving a car or flying a helicopter.

이온풍을 이용한 실린더 뒤의 후류 제어 (The wake flow control behind a circular cylinder using ion wind)

  • 현기탁;전중환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.459-462
    • /
    • 2002
  • Many active and passive flow control methods have been studied since decades, but there are only few works about flow control methods using ion wind. This paper presents an experimental study on the wake control behind a circular cylinder using ion wind, a bulk motion of neutral molecules driven by locally ionized air of corona discharge. Experiments are done f3r different electrohydrodynamic numbers - the ratio of an electrical body farce to a fluid Inertial force - from 0 to 2 and for the Reynolds number ranging from $4{\times}10^3\;to\;8{\times}10^3$. Pressure distributions over a cylinder surface are measured and flow visualizations are carried out by smoke wire method. Flow visualizations confirm that ion wind affects significantly the wake structure behind a circular cylinder and pressure drag could be dramatically reduced by the superimposing ion wind.

  • PDF