• Title/Summary/Keyword: passive monitor

Search Result 63, Processing Time 0.019 seconds

A Novel Hybrid Islanding Detection Method Using Digital Lock-In Amplifier (디지털 록인 앰프를 이용한 새로운 하이브리드 방식의 단독운전 검출법)

  • Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.77-79
    • /
    • 2019
  • Islanding detection is one of the most important issues for the distributed generation (DG) systems connected to the power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods may deteriorate the power quality of a power system. This paper proposes a novel hybrid islanding detection method based on Digital Lock-In Amplifier with no NDZ by monitoring the harmonics present in the grid. Proposed method detects islanding by passively monitoring the grid voltage harmonics and verify it by injecting small perturbation for only three-line cycles. Unlike FFT for the harmonic extraction, DLA HC have lower computational burden, moreover, DLA can monitor harmonic in real time, whereas, FFT has certain propagation delay. The simulation results are presented to highlight the effectiveness of the proposed technique. In order to prove the performance of the proposed method it is compared with several passive islanding detection methods. The experimental results confirm that the proposed method exhibits outstanding performance as compared to the conventional methods.

  • PDF

The Theory and Application of Diffusive Gradient in Thin Film Probe for the Evaluation of Concentration and Bioavailability of Inorganic Contaminants in Aquatic Environments (박막분산탐침(diffusive gradient in thin film probe)의 수중 생물학적 이용가능한 중금속 측정 적용)

  • Hong, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.691-702
    • /
    • 2013
  • This review paper summarizes the theory, application, and potential drawbacks of diffusive gradient in thin film (DGT) probe which is a widely used in-situ passive sampling technique for monitoring inorganic contaminants in aquatic environments. The DGT probe employs a series of layers including a filter membrane, a diffusive hydrogel, and an ionic exchange resin gel in a plastic unit. The filter side is exposed to an aquatic environment after which dissolved inorganic contaminants, such as heavy metals and nuclides, diffuse through the hydrogel and are accumulated in the resin gel. After retrieval, the contaminants in the resin gel are extracted by strong acid or base and the concentrations are determined by analytical instruments. Then aqueous concentrations of the inorganic contaminants can be estimated from a mathematical equation. The DGT has also been used to monitor nutrients, such as ${PO_4}^{3-}$, in lakes, streams, and estuaries, which might be helpful in assessing eutrophic potential in aquatic environments. DGT is a robust in-situ passive sampling techniques for investigating bioavailability, toxicity, and speciation of inorganic contaminants in aquatic environments, and can be an effective monitoring tool for risk assessment.

Hybrid Monitoring Scheme for End-to-End Performance Enhancement of Real-time Media Transport (실시간 미디어 전송의 종단간 성능 향상을 위한 혼성 모니터링 기법)

  • Park Ju-Won;Kim JongWon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10B
    • /
    • pp.630-638
    • /
    • 2005
  • As real-time media applications based on IP multicast networks spread widely, the end-to-end QoS (quality of service) provisioning for these applications have become very important. To guarantee the end-to-end QoS of multi-party media applications, it is essential to monitor the time-varying status of both network metrics (i.e., delay, jitter and loss) and system metrics (i.e., CPU and memory utilization). In this paper, targeting the multicast-enabled AG (Access Grid) group collaboration tool based on multi-Party real-time media services, a hybrid monitoring scheme that can monitor the status of both multicast network and node system is investigated. It combines active monitoring and passive monitoring approaches to measure multicast network. The active monitoring measures network-layer metrics (i.e., network condition) with probe packets while the passive monitoring checks application-layer metrics (i.e., user traffic condition by analyzing RTCP packets). In addition, it measures node system metrics from system API. By comparing these hybrid results, we attempt to pinpoint the causes of performance degradation and explore corresponding reactions to improve the end-to-end performance. The experimental results show that the proposed hybrid monitoring can provide useful information to coordinate the performance improvement of multi-party real-time media applications.

Exposure Assessment and Estimation of Nitrogen Dioxide on Office Worker Using Passive Monitor -Comparative Study of Seoul in Korea and Brisbane in Australia- (수동식 시료채취기를 이응한 사무실 직장인의 산화질소 노출평가 및 예측 -한국의 서울과 호주의 브리스베인 비교 연구-)

  • 양원호;손부순;김종오
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.247-255
    • /
    • 2002
  • Indoor and outdoor nitrogen dioxide (NO$_2$) concentrations were measured and compared with measurements of personal exposures of 95 persons in Seoul, Korea and 57 persons in Brisbane, Australia, respectively. Time activity diary was used to determine the impact on NO$_2$ exposure assessment and microenvironmental model to estimate the personal NO$_2$ exposure. Most people both Seoul and Brisbane spent their times more than 90% of indoor and more than 50% in home, respectively. Personal NO$_2$ exposures were significantly associated with indoor NO$_2$ levels with Pearson coefficient of 0.70 (p<0.01) and outdoor NO$_2$ levels with Pearson coefficient of 0.66 (p<0.01) in Seoul and of 0.51 (p<0.01) and of 0.33 (p<0.05) in Brisbane, respectively. Using microenvironmental model by time weighted average model, personal NO$_2$ exposures were estimated with NO$_2$ measurements in indoor home, indoor office and outdoor home. Estimated NO$_2$ measurements were significantly correlated with measured personal exposures (r = 0.69, p<0.001) in Seoul and in Brisbane (r = 0.66, p<0.001), respectively. Difference between measured and estimated NO$_2$ exposures by multiple regression analysis was explained that NO$_2$ levels in near workplace and other outdoors in Seoul (p = 0.023), and in transportation in Brisbane (p = 0.019) affected the personal NO$_2$ exposures.

Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell (광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구)

  • Lee, Sin-Pyo;Go, Sang-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

Derivation of the Ambient Nitrogen Dioxide Mixing Ratio over a Traffic Road Site Based on Simultaneous Measurements Using a Ground-based UV Scanning Spectrograph

  • Lee, Han-Lim;Noh, Young-Min;Ryu, Jae-Yong;Hwang, Jung-Bae;Won, Yong-Gwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • Simultaneous measurements using a scanning spectrograph system and transmissometer were performed for the first time over an urban site in Gwangju, Korea, to derive the ambient $NO_2$ volume mixing ratio. The differential slant column densities retrieved from the scanning spectrograph system were converted to volume mixing ratios using the light traveling distance along the scanning line of sight derived from the transmissometer light extinction coefficients. To assess the performance of this system, we compared the derived $NO_2$ volume mixing ratios with those measured by an in situ chemiluminescence monitor under various atmospheric conditions. For a cloudless atmosphere, the linear correlation coefficient (R) between the two data sets (i.e., data derived from the scanning spectrograph and from the in situ monitor) was 0.81; the value for a cloudy atmosphere was 0.69. The two sets of $NO_2$ volume mixing ratios were also compared for various wind speeds. We also consider the measurement errors, as estimated from an error propagation analysis.

The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers (확산포집기로 공기중 ppb 농도수준의 휘발성유기물질 포집시 확산길이와 기류변화가 시료포집속도에 미치는 영향)

  • Byeon, Sang-Hoon;Stock, Thomas H.;Morandi, Maria T.;Afshar, Masoud;Cross, Jay
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.34-41
    • /
    • 2001
  • Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.

  • PDF

Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries (능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교)

  • Jang, Mi;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

Preliminary study of passive acoustic monitoring of finless porpoises Neophocaena asiaeorientalis around the Southwest offshore wind farm in Korea (서남해 해상풍력 실증단지 주변에서의 수동 음향 관측을 이용한 상괭이 모니터링 가능성 연구)

  • Yoon, Young Geul;Yang, Wonjun;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.537-545
    • /
    • 2021
  • Due to the accelerated development and transformation of coastal waters by humans, damage to marine mammals is a concern. To understand how coastal development may affect marine mammals, it is essential to determine their distribution characteristics. In this study, the appearance of finless porpoises was confirmed by passive acoustic monitoring around the Southwest offshore wind farm in July, 2020. Although there were no visual observation results of finless porpoises in the research area, the clicks measured in the offshore wind farm were verified by comparing with acoustic characteristics of the clicks measured in the area with a high detection rate. During the experimental period, clicks of finless porpoises were recorded for ten consecutive days, and Clicks per Porpoise Positive Minute (CPPM) was 40.7 clicks min-1, Porpoise Positive Minutes (PPM) was 9.7 %, Encounter duration and waiting time were 18.2 min and 94.9 min respectively. This study provides information on the appearance of them in the Southwest offshore wind farm and this result may help to monitor the impact of marine mammals from wind farm operation.

Method of Display and Processing of Binocular Stereoscopic Image for 3D Endoscopy (3차원 내시경술을 위한 양안 입체 영상처리 및 디스플레이 방법)

  • 송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.531-538
    • /
    • 1998
  • This paper represents the design of 3D endoscopic image processing system in order to Improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. The proposed 3D systems have four features of stereo endoscopic image processing The multiplexer give field seauential stereo for recording and for aligning cameras and viewing stereo with 3D monitor. Demultiplexing of the field sequential image which separates out the R and L images for dual TFT-LCD 3D monitor viewed with passive polarized glasses. separable processing of the left and right eye images, and design of TFT-LCD 3D monitor. The viewing angle, zone, and image quality of the Polarization-type Stereoscopic Display (SM500TFT-3D) system which we have developed using 15 Samsung TFT-1.CD with a screen resolution of 1024×768 pixels were measured and compared with those of Electric Shutter-type Stereoscopic Display system. The result of experiments shows that the Polarization-type Stereoscopic Display System using TFT-LCD has a wade viewing angle and zone which Is necessary fort multi-view and it has better image quality and stability of the optical performances than the Electric Shutter-type does.

  • PDF