• Title/Summary/Keyword: passive connection

Search Result 89, Processing Time 0.028 seconds

Vibration mitigation of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Sun, Limin;Jiang, Xiaolu
    • Smart Structures and Systems
    • /
    • v.9 no.1
    • /
    • pp.35-53
    • /
    • 2012
  • Mechanical dampers have been proved to be one of the most effective countermeasures for vibration mitigation of stay cables in various cable-stayed bridges over the world. However, for long stay cables, as the installation height of the damper is restricted due to the aesthetic concern, using passive dampers alone may not satisfy the control requirement of the stay cables. In this connection, semi-active MR dampers have been proposed for the vibration mitigation of long stay cables. Although various studies have been carried out on the implementation of MR dampers on stay cables, the optimal damping performance of the cable-MR damper system has yet to be evaluated. Therefore, this paper aims to investigate the effectiveness of MR damper as a semi-active control device for the vibration mitigation of stay cable. The mathematical model of the MR damper will first be established through a performance test. Then, an efficient semi-active control strategy will be derived, where the damping of MR damper will be tuned according to the dynamic characteristics of stay cable, in order to achieve optimal damping of cable-damper system. Simulation study will be carried out to verify the proposed semi-active control algorithm for suppressing the cable vibrations induced by different loading patterns using optimally tuned MR damper. Finally, the effectiveness of MR damper in mitigating multi modes of cable vibration will be examined theoretically.

AKARI Observation of the North Ecliptic Pole (NEP) Supercluster at z=0.087

  • Ko, Jong-Wan;Im, Myung-Shin;AKARINEP-Wideteam, AKARINEP-Wideteam
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.74.2-74.2
    • /
    • 2010
  • We present a multi-wavelength study of a supercluster in the NEP region at z=0.087, using AKARI (Infrared space telescope) NEP-Wide (5.8 deg2) survey which has obtained an unique IR imaging dataset with contiguous wavelength coverage from 2 to $24{\mu}m$, overcoming the Spitzer limitation of imaging capability at $10-20{\mu}m$. The NEP-Wide survey is also covered in other wavelength such as X-ray, Radio, GALEX UV in the archive, optical (BRI from Maidanak 1.5m and CFHT's MegaPrime), and NIR imaging data (JH from KPNO 2.1m), with nearly 1900 optical spectra, mostly obtained by our group using MMT/Hectospec and WIYN/Hydra. Armed with the multiwavelength datasets, we investigate the connection between IR properties of galaxies and their environments as a tool to understand the evolution of galaxies in a supercluster environment. Specific attention will be given to MIR emission which can trace star formation activities and passive phases right after post-starbursts, and its relation to other wavelength data.

  • PDF

A Study on the Role of Vessel Traffic Service System (해상교감관별 시스템의 지리적 후문에 관한 연구)

  • 이학선
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.43-63
    • /
    • 1996
  • The purpose of this study is to find out what is the functional role of VTS in order to get the people concerned with marine traffic/transportation understand about VTS. VTS could be described as the essential risk management system in both cost effective on cost-benefit analysis and the sea space or time management at port, coastal environment. The important role of the VTS are those functions such as the decision making infrastructure, the passive/active safety measures at sea. VTS could not control/regulate marine traffic as strong as ATC(Air Traffic Control) owing to the marine traffic characters. However, the right and responsibility of VTS finally are belong to the master, pilot and mariners. For the benefit of the electronic technology development, VTS system also cloud be upgraded to communication system from information system. In connection with these system upgrading, the right and responsibility of VTS/staff should be supported by domestic legal system. The followings are presented for VTS to be effective. First, the cooperation and understanding of VTS between the peoples concerned with marine traffic/transportation are essential. Because they are all data supplier and also information consumers. Second, VTS staff/regulator should be selected, educated, trained accordingly as per their career, ability, quality, qualification, certification and etc. Third, the port reliability from VTS users depends on the factors such as economic interests, safety and effectiveness/efficiency of VTS.

  • PDF

A Three-Phase High Frequency Semi-Controlled Battery Charging Power Converter for Plug-In Hybrid Electric Vehicles

  • Amin, Mahmoud M.;Mohammed, Osama A.
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.490-498
    • /
    • 2011
  • This paper presents a novel analysis, design, and implementation of a battery charging three-phase high frequency semi-controlled power converter feasible for plug-in hybrid electric vehicles. The main advantages of the proposed topology include high efficiency; due to lower power losses and reduced number of switching elements, high output power density realization, and reduced passive component ratings proportionally to the frequency. Additional advantages also include grid economic utilization by insuring unity power factor operation under different possible conditions and robustness since short-circuit through a leg is not possible. A high but acceptable total harmonic distortion of the generator currents is introduced in the proposed topology which can be viewed as a minor disadvantage when compared to traditional boost rectifiers. A hysteresis control algorithm is proposed to achieve lower current harmonic distortion for the rectifier operation. The rectifier topology concept, the principle of operation, and control scheme are presented. Additionally, a dc-dc converter is also employed in the rectifier-battery connection. Test results on 50-kHz power converter system are presented and discussed to confirm the effectiveness of the proposed topology for PHEV applications.

A Study on the Active Traceback Scheme Respond ing to a Security Incident (침해사고 대응을 위한 능동적 역추적 기법에 관한 연구)

  • Park Myung Chan;Park Young Shin;Choi Yong Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.27-34
    • /
    • 2005
  • Current security reinforcement systems are Passive defense system that only blocks filter to all traffic from the attacker. So, Those are weak re-attack and Stepping Stones attack because active response about attacker is lacking. Also, present techniques of traceback need much time and manpower by log information collection and trace through the personal inspection and active response is lacking. In this paper, We propose technique for TCP connection traceback that can apply in present internet and trace to inserted marking on IP header to correspond re-attack and Stepping Stones attack. Therefore, Proposed technique is unnecessary correction of existing network component and can reduce size of marked information and overhead of resources.

  • PDF

Practical Silicon-Surface-Protection Method using Metal Layer

  • Yi, Kyungsuk;Park, Minsu;Kim, Seungjoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.470-480
    • /
    • 2016
  • The reversal of a silicon chip to find out its security structure is common and possible at the present time. Thanks to reversing, it is possible to use a probing attack to obtain useful information such as personal information or a cryptographic key. For this reason, security-related blocks such as DES (Data Encryption Standard), AES (Advanced Encryption Standard), and RSA (Rivest Shamir Adleman) engines should be located in the lower layer of the chip to guard against a probing attack; in this regard, the addition of a silicon-surface-protection layer onto the chip surface is a crucial protective measure. But, for manufacturers, the implementation of an additional silicon layer is burdensome, because the addition of just one layer to a chip significantly increases the overall production cost; furthermore, the chip size is increased due to the bulk of the secure logic part and routing area of the silicon protection layer. To resolve this issue, this paper proposes a practical silicon-surface-protection method using a metal layer that increases the security level of the chip while minimizing its size and cost. The proposed method uses a shift register for the alternation and variation of the metal-layer data, and the inter-connection area is removed to minimize the size and cost of the chip in a more extensive manner than related methods.

Efficient Vibration Control Approach of Two Identical Adjacent Structures (동일한 인접구조물의 효율적 진동제어방안)

  • Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.56-63
    • /
    • 2014
  • This study proposes a new control approach for efficient vibration suppression of two identical adjacent structures. The conventional control approach of two adjacent structures is to interconnect the two structures with passive, semi-active or active control devices. However, when the two adjacent structures are identical to each other, their dynamical behaviors such as frequency and damping properties are also the same. In this case, the interconnected control devices cannot exhibit the dissipative control forces on the both structures as expected since the relative displacements and velocities of the devices become close to zero. In other words, the interconnection method does not work for the twin structures as enough as expected. In order to solve this problem, we propose several new control approaches to effectively and efficiently reduce the identically-fluctuating responses of the adjacent structures with minimum control efforts. In order to demonstrate the proposed control systems, the proposed several control systems are optimally designed and their control performances are compared with that of the conventional optimal control system where each TMD(tuned mass damper) is installed in each structure for independent control purpose. The simulated results show that one of the proposed control systems(System 04) is able to guarantee enhanced control performance compared with the conventional system.

Half-Bridge Zero Voltage Switching Converter with Three Resonant Tanks

  • Lin, Bor-Ren;Lin, Wei-Jie
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.882-889
    • /
    • 2014
  • This paper presents a zero voltage switching (ZVS) converter with three resonant tanks. The main advantages of the proposed converter are its ability to reduce the switching losses on the power semiconductors, decrease the current stress of the passive components at the primary side, and reduce the transformer secondary windings. Three resonant converters with the same power switches are adopted at the low voltage side to reduce the current rating on the transformer windings. Using a series-connection of the transformer secondary windings, the primary side currents of the three resonant circuits are balanced to share the load power. As a result, the size of both the transformer core and the bobbin are reduced. Based on the circuit characteristics of the resonant converter, the power switches are turned on at ZVS. The rectifier diodes can be turned off at zero current switching (ZCS) if the switching frequency is less than the series resonant frequency. Therefore, the reverse recovery losses on the rectifier diodes are overcome. Experiments with a 1.6kW prototype are presented to verify the effectiveness of the proposed converter.

Suspended Columns for Seismic Isolation in Structures (SCSI): A preliminary analytical study

  • Shahabi, Ali Beirami;Ahari, Gholamreza Zamani;Barghian, Majid
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.743-755
    • /
    • 2019
  • In this paper, a new system of seismic isolation for buildings - called suspended columns - is introduced. In this method, the building columns are placed on the hinged cradle seats instead of direct connection to the foundation. In this system, each of the columns is put on a seat hung from its surrounding area by a number of cables, for which cavities are created inside the foundation around the columns. Inside these cavities, the tensile cables are hung. Because of the flexibility of the cables, the suspended seats vibrate during an earthquake and as a result, there is less acceleration in the structure than the foundation. A Matlab code was written to analyze and investigate the response of the system against the earthquake excitations. The findings showed that if this system is used in a building, it results in a significant reduction in the acceleration applied to the structure. A shear key system was used to control the structure for service and lateral weak loads. Moreover, the effect of vertical acceleration on the seismic behavior of the system was also investigated. Effect of the earthquake characteristic period on the system performance was studied and the optimum length of the suspension cables for a variety of the period ranges was suggested. In addition, measures have been taken for long-term functioning of the system and some practical feasibility features were also discussed. Finally, the advantages and limitations of the system were discussed and compared with the other common methods of seismic isolation.

A Study on the Connection between Nature and Architectural Space in Le Corbusier's Venice Hospital Project

  • Yoon, Eunji;Lim, Yeonghwan
    • Architectural research
    • /
    • v.22 no.4
    • /
    • pp.113-122
    • /
    • 2020
  • Hospital architecture must be planned as a therapeutic space. Numerous studies have proven that exposure to nature has a healing effect. However, research on the architecture itself about this issue is still insufficient. This study analyzed Le Corbusier's Venice hospital project and its architectural configurations with nature. Le Corbusier had been interested in blurring the interior/exterior line to draw nature inside. In his projects, nature was conceived in an abstract sense as "something green." However, in the hospital project, natural elements including vegetation, the lagoon, and light, and the landscape scenery they created, were considered in the harmony of the architectural space. The architectural spaces with courtyards, pilotis, and roof gardens provided views and direct access to nature, and in the interior spaces, the connections to these external spaces and the permeation of views of nature and sunlight were incorporated. Many spaces provided the possibility to actually encounter nature, with a variety of indoor/outdoor space configurations rather than a merely passive placing of some natural elements. This project is considered to be an important reference for contemporary hospital architecture, since the architectural space and nature connected through various spatial configurations also in healthcare programs. As Le Corbusier emphasized, sunlight, vegetation, and also architectural space should be an essential factor in therapeutic hospital architecture planning.