• Title/Summary/Keyword: particle size separation

Search Result 245, Processing Time 0.032 seconds

The Preparation of D-Phenylalanine Imprinted Microbeads by a Novel Method of Modified Suspension Polymerization

  • Khan, Hamayun;Park, Joong-Kon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.503-509
    • /
    • 2006
  • Molecularly imprinted polymeric microbeads (MIPMs) were prepared by the suspension and modified suspension polymerization methods using D-phenylalanine as the template, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, toluene as the porogen, polyvinyl alcohol as the stabilizer, and sodium dodecyl sulfate as the surfactant. The addition of a surfactant to the conventional suspension polymerization mixture decreased the mean particle size of the MIPMs and increased the adsorption selectivity. For the modified suspension polymerization method, the mean particle size of the MIPMs was smaller than the particle size of MIPMs prepared via conventional suspension polymerization. Moreover, the adsorption selectivity improved considerably compared to the adsorption selectivities of MIPs reported previously.

Effect of Forming Process and Particle Size on Properties of Porous Silicon Carbide Ceramic Candle Filters (성형공정(成形工程)과 원료입도(原料粒度)가 다공성(多孔性) 탄화규소(炭火硅素) 세라믹 캔들 필터 특성(特性)에 미치는 영향(影響))

  • Han, In-Sub;Seo, Doo-Won;Hong, Ki-Seog;Woo, Sang-Kuk
    • Resources Recycling
    • /
    • v.19 no.5
    • /
    • pp.31-43
    • /
    • 2010
  • To fabricate porous SiC candle filter for filtration facility of the IGCC system, the candle type filter preforms were fabricated by ramming and vacuum extrusion process. A commercially available ${\alpha}$-SiC powders with various particle size were used as starting raw materials, and $44\;{\mu}m$ mullite, $CaCO_3$ powder were used as non-clay based inorganic sintering additive. The candle typed preforms by ramming process and vacuum extrusion were sintered at $1400^{\circ}C$ for 2h in air atmosphere. The effect of forming method and particle size of filter matrix on porosity, density, strength (flexural and compressive strength) and microstructure of the sintered porous SiC candle tilters were investigated. The sintered porous SiC filters which were fabricated by ramming process have more higher density and strength than extruded filter in same particle size of the matrix, and its maximum density and 3-point bending strength were $2.00\;g/cm^3$ and 45 MPa, respectively. Also, corrosion test of the sintered candle filter specimens by different forming method was performed at $600^{\circ}C$ for 2400h using IGCC syngas atmosphere for estimation of long-term reliability of the candle filter matrix.

Measurement Technique of Particle Sizing in Spay Flow (분무 유동의 입경 계측 기법에 관한 연구)

  • Yang, Chang-Jo;Kim, Jeong-Hwan;Oh, Jong-Hwan;Kim, Mann-Eung;Lee, Young-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.534-539
    • /
    • 2005
  • Particle image analyzer for measuring droplet size has been developed. Image processing technique was used with relaxation method. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. The measurement results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF

The Separation of Colloid Particles of Different Sizes by Dielectrophoresis (유전이동을 이용한 콜로이드 입자의 크기에 따른 분리)

  • Hwang, Yeon
    • Korean Journal of Materials Research
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2007
  • The separation of the small colloidal particles from the mixture of two different sized particles using AC dielectrophoresis phenomenon was studied. The spherical mono-dispersed polystyrene particles dispersed in pure water were put into a perfusion chamber on a substrate, and AC electric fold was applied to the glass substrate with Au electrodes in 4 mm distance. The AC frequency was fixed at 1 kHz and the intensity of the field was varied from 25 V/cm to 160 V/cm. After applying the AC field, the degree of the chain formation that resulted from the particle movements by dielectrophoresis was observed by optical microscope. The mixture of the $1\;{\mu}m\;and\;5\;{\mu}m$ sized polystyrene particles at 0.5 vol% concentrations for each size was set in the dielectrophoresis conditions of 1 kHz and 100 V/cm. At this condition large $5\;{\mu}m$ sized polystyrene particles formed chains, on the contrary the $1\;{\mu}m$ sized polystyrene particles formed no chains. After water flowing for 20 min, it was found that small particles that were floating in the chamber had been removed by the water flowing.

Effect of internal pressure variation on the ceramic particle separation characteristics : computer simulation (분리기 내부 압력 변화에 따른 세라믹 입자 분리 거동 전산모사)

  • 우효상;심광보;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.304-308
    • /
    • 2003
  • By controlling the internal pressure in the cyclone separator, we investigated the separation charateristics of $Al_2O_3$, $Fe_2O_3$ particles with the internal pressure variation. 3-dimensional Langrangian approach was applied for the analysis of the particles separation, and then the minimum cut diameter of the separated particles and the separation rate were calculated through tracking the particle trajectories. The density of the argon gas for transporting particles was decreased corresponding the pressure decrease, consequently, caused the internal pressure drop in the cyclone separator. For that reason the finer particles were separated as the pressure was changed from an atmospheric pressure to an low pressure. Specifically, at 50 torr pressure, $Al_2O_3$ particles of the size of about 4 $\mu\textrm{m}$ and $Fe_2O_3$particles of about 3 $\mu\textrm{m}$ could be separated.

Recent Research Trends of Mixed Matrix Membranes for CO2 Separation (이산화탄소 분리용 혼합 매질 분리막 최신 연구 동향)

  • Chi, Won Seok;Lee, Jae Hun;Park, Min Su;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.373-384
    • /
    • 2015
  • In the past few decades, polymeric membrane has played an important role in gas separation applications. For the separation of $CO_2$, one of greenhouse gases, high permselectivity, long-term stability and scale-up are needed. However, conventional polymeric membranes have shown a trade-off relation between permeability and selectivity while inorganic materials are highly permeable but expensive. Mixed matrix membranes (MMMs) combining the advantages of both polymeric and inorganic materials have become a possible breakthrough for the next-generation gas separation membranes. The MMMs could be either symmetric or asymmetric but the latter is more preferred to improve the permeance. Important factors influencing the MMM fabrication include homogeneous distribution of inorganic particles and good interfacial contact between inorganic filler and organic matrix. Recently, metal organic frameworks (MOFs) have received much attention as a new class of porous crystalline materials and a potential candidate for $CO_2$ separation. Zeolitic imidazolate frameworks (ZIFs), a sub-branch of MOFs, are the most widely used in MMMs due to small particle size and appropriate pore size for $CO_2$ separation. One of the major issues associated with the incorporation of porous particles in a polymeric membrane is to control the microstructure of the porous particle materials such as particle size, orientation, and boundary conditions etc. In this review, major challenges surrounding MMMs and the strategies to tackle these challenges are given in detail.

Preparation and Application of Functional Microsphere (II) Formation and Characteristics of Poly(ethylene-co-vinylacetate) Microsphere with Disperse Dye (기능성 마이크로스피어의 제조와 응용(II) 분산염료를 함유한 에틸렌-비닐아세테이트 중합체의 마이크로스피어 제조와 특성)

  • Lee, Shin-Hee;Cho, Hyun;Park, Soo-Min
    • Fashion & Textile Research Journal
    • /
    • v.10 no.3
    • /
    • pp.371-376
    • /
    • 2008
  • Poly(ethylene-co-vinylacetate) (EVA) microspheres were prepared by thermally induced phase separation (TIPS) in toluene. The microsphere formation occurred by the nucleation and growth mechanism in metastable region. The effects of the concentration and component of the polymer and cooling rate on microsphere formation were investigated. The microsphere formation and growth were followed by the cloud point of the optical microscope measurement. The microsphere size distribution, which was obtained by particle size analyzer, became broader when the polymer concentration was higher, the content of vinyl acetate in EVA copolymer was higher, the cooling rate of EVA copolymer solution were lower. The content of disperse dye in EVA microsphere was obtained by TGA thermal analysis, the dye content of EVA15 and EVA18 were 3.5 and 2.0 wt% respectively.

A Study on the Crystallization of Low Density Polyethylene Microparticles in $n$-Dodecanol Solution ($n$-Dodecanol 용액에서 저밀도폴리에틸렌 마이크로 입자 결정화에 관한 연구)

  • Park, Keun-Ho;Jang, Young-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.306-312
    • /
    • 2011
  • In this study, we are crystallized to the low density polyethylene (LDPE) micro-particles in $n$-dodecanol solution by thermally induced phase separation(TIPS) method. The Low density polyethylene micro-particles is used in a wide variety of polymer coatings and industrial application. The utility of that for a particular application depends on a number of factors such as the particle size and distribution, and chemical composition of the materials. However, there are still needs for new methods of preparation which will provide the structure with unique sizes. The widely used processes for micro-size particles are crystallization method and thermally induced phase separation. TIPS process based on the phase separation mechanism was performed for the LDPE system which undergoes liquid-solid phase separation. Effects of various operating parameters were examined on the structure variation of the particles. Professionality, take-up speed and crystallization rate depended on temperature and concentration of polymer in solution.

COAL DESULFURIZATION BY MAGNETIC SEPARATION METHODS (자력선별법에 의한 선탄의 탈황)

  • Jeon, Ho-Seok;Lee, Jae-Jang
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.175-185
    • /
    • 1995
  • Under the new environmental regulations announced by the government, utilities will have to cut their sulfur dioxide emissions by 60% from 1991 levels by the year of 1999. Sulfur dioxide emissions can be reduced prior to combustion by physical, chemical or biological coal cleaning. The new technology of high gradient magnetic separation (HGMS) offers the potential of economic separatoins of a variety of fine, weakly magnetic minerals including inorganic sulfur and many ash-forming minerals from coals. In the present paper, magnetic separation tests have been conducted on Korean anthracite and high-sulfur Chinese coal to investigate the feasibility of these techniques for reducing sulfur content from coals. In wet magnetic separation, the studied operating parameters include particle size, pH, matrix types, feed solids content, feed rate, number of cleaning stages and etc. The results shows that for wet separation, 60~70% of total sulfur was removed from coals with over 80% combustible recovery, on the other hand, for dry separation, 47.6% of total sulfur was removed from coals with 75% recovery.

  • PDF

Separation and Characterization of Dust and Ground Water Particulates Using Gravitational SPLITT Fractionation.

  • Lee, Seung Ho;Park, Hui Yeong;Lee, Sang Geun;Yong, Seong Gwon;Eum, Cheol Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.6
    • /
    • pp.616-622
    • /
    • 2001
  • Split-flow thin (SPLITT) cell Fractionation(SF) is a technique that allows separation of particulates and macromolecules into two fractions. A gravitational SF(GSF) system is constructed and tested for its applicability for separation of dust and ground water particulates. When tested with polystyrene latex particles, experimental data were in good agreements with theory. The 9.8 and 21.4㎛ polystyrene particles were successuflly separated in a continuous mode, where the mixture is continuously fed into the GSF channel allowing separation in a large sacle. The GSF system is successfully applied to continuous separation of dust and ground water particels based on the sedimentation coefficient, which is closely related to the particle size. The separations were confirmed by microscopy and energy-dispersive X-ray (EDX) analysos.