• Title/Summary/Keyword: particle removal efficiency

Search Result 350, Processing Time 0.024 seconds

Generation Characteristics of Ozone and NOx and Particle Removal in the Electrostatic Precipitators (코로나 방전 방식에 따른 전기집진기의 오존, NOx 발생 및 입자제거 특성)

  • Noh, Kwang-Chul;Lee, Young-Ho;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1442-1449
    • /
    • 2003
  • We investigated the amount of the toxic gases emitted from the Electrostatic Precipitators(ESPs), which are currently used as the indoor air cleaners. The existing wire-to-plate(WTP) and neddle-to-plate(NTP) types of ESP designs are considered as the experimental corona dischargers. Using the voltage, the polarity of wire, the number of needles of NTP as the input variables, we studied the generation characteristics of ozone and $NO_{x}$ and the particle removal efficiency in the ESPs. As the results, we found out that the concentration of ozone, $NO_{2}$ and $NO_{x}$ is increased with increasing the voltage and the number of needles, but the amount of NO is decreased. And we observed that the generation rates of ozone and $NO_{x}$ are mainly related with the corona region through the photographs. Finally the experimental results showed that the particle removal efficiency of ESP with WTP type charger is more superior to that with NTP type chargers at the same voltage.

CFD Explanation and Verification of Multi Inner Stage Cyclone for The Particle Removal (미세입자 제거를 위한 Multi Inner Stage Cyclone의 CFD 해석 및 검증)

  • Lee, Sang Jun;Kim, Chun-Lee;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.1
    • /
    • pp.149-156
    • /
    • 2013
  • In this paper, Commercial program, STAR-CCM+, was used for computer simulation. And also Multi Inner Stage(MIS) cyclone which especially designed for the real experiments of particle removal efficiency. Under negative pressure condition of outlet, computer simulation was performed to predict the removal efficiency for $5{\mu}m$ and $10{\mu}m$ particles by using a turbulence model and lagrangian method. The simulation results are 55.7% and 64.1% for $5{\mu}m$ and $10{\mu}m$ particles, respectively. To compare the simulation results with the actual test of MIS cyclone, we generated the $SiO_2$ particles by heat reactor. Although removal efficiency of actual tests is 63~76% at different flow rate, the size of $SiO_2$ particles which confirmed by SEM(scanning electron microscope) and WAPS(wide range aerosol particle spectrometer) is too small(15~30nm) to compare each results. And so the alternative experiments were performed by using commercial alumina particles ($5{\mu}m$, $10{\mu}m$ and $20{\mu}m$). It was shown that the actual removal efficiency, 76~95%, from MIS cyclone is higher than simulated one.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Enhancement of phosphate removal using stabilized Fe-Mn particle (Fe-Mn 입자의 안정화를 통한 인산염 효율 향상)

  • Seoyeon Kang;Jeongwoo Shin;Byugnryul An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.375-382
    • /
    • 2023
  • The binary oxide adsorbent using Fe and Mn (Fe-Mn) has been prepared by precipitation method to enhance the removal of phosphate. Different amounts of chitosan, a natural organic polymer, were used during preparation of Fe-Mn as a stabilizer to protect an aggregation of Fe-Mn particles. The optimal amount of chitosan has been determined considering the separation of the Fe-Mn particles by gravity from solution and highest removal efficiency of phosphate (Fe-Mn10). The application of Fe-Mn10 increased removal efficiency at least 15% compared to bare Fe-Mn. According to the Langmuir isotherm model, the maximum uptake (qm) and affinity coefficient (b) were calculated to be 184 and 240 mg/g, and 4.28 and 7.30 L/mg for Fe-Mn and Fe-Mn10, respectively, indicating 30% and 70% increase. The effect of pH showed that the removal efficiency of phosphate was decrease with increase of pH regardless of type of adsorbent. The enhanced removal efficiency for Fe-Mn10 was maintained in entire range of pH. In the kinetics, both adsorbents obtained 70% removal efficiency within 5 min and 90% removal efficiency was achieved at 1 h. Pseudo second order (PSO) kinetic model showed higher correlation of determination (R2), suggesting chemisorption was the primary phosphate adsorption for both Fe-Mn and Fe-Mn10.

Effect of Anionic Polymer on Particle Size Distribution in PAC Coagulation Process for Phosphorus Removal (PAC를 이용한 인제거 공정에서 음이온계 고분자 첨가가 입도 분포에 미치는 영향)

  • Kim, Sunghong;Lee, Dongwoo;Kim, Donghan;Kim, Dooil
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.170-175
    • /
    • 2013
  • Achieving very low phosphorus levels in treated wastewater will require the installation of additional treatment. Phosphorus removal experiments by chemical coagulation were carried out for the effluent of wastewater treatment plant in this study. TP (total phosphorus) or phosphate were highly related to the addition of PAC (poly aluminium chloride) which is one of the inorganic coagulants. But, organic polymer did not significantly affect the phosphorus removal efficiency. Polymer affected the flocculation of particle especially particle matter less than 10 micrometer so, the number of micro particles was decreased by polymer dose. Chlorination would not affect on chemical coagulation process and TP and turbidity could be effectively removed by the co-addition of PAC and polymer.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Numerical Analysis of Ventilation System for Dust Removal Inside the Enclosed Conveyor Belt (밀폐된 컨베이어 벨트 내부의 분진 제거를 위한 환기 시스템의 수치해석적 분석)

  • Yeseung Lee;Ki Jin Jeong;Jong Min Kim;Jung-Hun Noh
    • Particle and aerosol research
    • /
    • v.19 no.2
    • /
    • pp.43-53
    • /
    • 2023
  • In this study, the ventilation system of the enclosed conveyor belt for coal transportation was evaluated, and the particle removal efficiency according to the ventilation conditions was identified using computational fluid dynamics and particle behavior analysis. The most effective way to remove dust generated inside the closed conveyor belt is to adjust the position of the exhaust port of the duct so that the air is exhausted around the rear of the conveyor belt. And this method seems to work for another narrow and long spaces where air enters in one direction. In addition, when the air flow rate of the each duct was less than 300 CMM, it was efficient to increase the flow rate of the duct located at the rear of the conveyor belt, and when the flow rate of the each duct was higher than 300 CMM, it was efficient to increase the flow rate of the duct located at the front of the conveyor belt.

A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate (황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거)

  • 서정민
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

Study on the Simulation for the Removal of Different Sized Particles in Suspension by Deep-Bed Filtration

  • Choo, Chang-Upp
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.18-22
    • /
    • 2005
  • A model was proposed for investigating the particle removal from suspension with particles of different sizes by deep-bed filtration, and the collection efficiency was predicted by computer simulation. Deposited particles on the pore surface may act as additional collector and reduce the pore size, which contribute to the improved collection efficiency with increase of deposition. Computer experiments for suspension of particles of three sizes and its equivalent size of mono particles were carried out and compared. The collection efficiency of suspension with poly-dispersed particles shows higher efficiency than that of suspension with mono-dispersed particles. Also the collection efficiency of smell particle of mixture is higher that that of same uniform size particles.

The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona (충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성)

  • 김은호
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.