• Title/Summary/Keyword: partial test

Search Result 1,787, Processing Time 0.032 seconds

Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement (부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가)

  • Park, Dae-Won;Choi, Su-Yeon;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

Improvement of the resistance to Treeing by additive in Low Density Polyethylene (첨가재에 의한 저밀도 폴리에틸렌의 내트리잉성 향상)

  • 김봉협;임기조
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.1
    • /
    • pp.17-25
    • /
    • 1986
  • Discussions on this paper are related to the effects of organic materials to treeing phenomena of low density polyethylene. As additives, 11 kinds of organic compounds are selected by considering the respective features such as melting point, boiling point, electron affinity as well as molecular structure, and then the specimens of low density polyethylene are prepared by blending with 10wt% of the selected additives. For the comparison of effectiveness of treeing resistance and interpretation of the mechanism of compounds as treeing retardants, several investigations such as the tree acceleration test, the prestressed test and the measurement of internally occurred partial discharge are carried out. As the results, meta-Cresol is regard as the most effective retardant among those, and it is supposed that this aromatic compound to be comprised of radical having large electron affinity has strong capability to accept energetic electron to prevent or delay the growth of discharge streamer. Furthermore, by activating partial discharge at the wall of tree pit through the function of trapped electron at this material, the gas pressure in the pit is increased up to prevent the growth of streamer.

  • PDF

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

Filter Design for Detecting High-Frequency Partial Discharge (고주파 부분방전 시험을 위한 필터 설계)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Choi, Chung-Seog;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.68-71
    • /
    • 2007
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke probe and oscilloscope (TDS-3054, Tektronix).

  • PDF

Development of UHF Partial Discharge Sensor for Intelligent distribution Facilities (지능형 배전기기를 위한 UHF 부분방전 센서 개발)

  • Cho, Young-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Gun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.161-162
    • /
    • 2007
  • This paper is analyzed the internal type UHF sensors that be able to monitor the condition of the distribution facilities and the location selecting of that sensors. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

Development of Automated Ultrasonic Testing System for Partial Joint-Weld of Heat Exchanger's Header to Tube in Power Plant (발전소 열교환기 헤더와 튜브의 부분 용입형 용접부 초음파 자동검사시스템 개발)

  • Lee, Jin-Hyuk;Lim, Seong-Jin;Park, Ik-Keun;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • A power plant's heat exchangers work under poor conditions, such as high temperature, high pressure, corrosion, mechanical stress and vibration. Especially, partial joint-weld of heat exchanger's header to stub-tube is the place where incomplete penetration flaws can easily occur. But, it is hard to evaluate the safety of the structure by conventional nondestructive testing techniques. So it is necessary to test integrity of the weld inside and to develop testing technique and equipment that can detect the flaws at the weld point in order to enhance reliability of the test result. In this study, we developed a suitable automated ultrasonic testing system that can inspect the partial joint-weld of header to stub-tube of power plant. Finally, we showed the efficiency of the automated ultrasonic-testing-system from the application.

Effect of Forward, Backward Walking using Partial Weight Bearing on Walking of the Patient with Incomplete Spinal Cord Injury (부분 체중지지를 이용한 앞, 뒤로 걷기 운동이 불완전 척수손상환자의 보행에 미치는 효과)

  • Kim, Seok-Hwan;Chung, Jae-Hoon
    • PNF and Movement
    • /
    • v.9 no.2
    • /
    • pp.29-37
    • /
    • 2011
  • Purpose : The purpose of this study was to find out of an effect of forward, backward walking using partial weight bearing on walking of the patient with incomplete spinal cord injury. Methods : The average age, and the term of being sick of 6 patients who were selected as the subjects with incomplete spinal cord injury and who received medical attention in the National Rehabilitation Hospital, was 50.3 years old, and 10.7 months, and those were also the patients that were classified as ASIA-C or D by ASIA. The forward, backward walking using a partial weight bearing system as the research method, took total 6 weeks, 3 days per week, 3 times per day, total 45 minutes for each time(15 minutes for a time, 5 minutes for a breathing time), and the 15 minutes was used for forward walking 7.30 minutes, backward walking for 7.30 minutes, to find out before and after the test of WISCI, PCI, Walking Speed, Motor Score of Lower Limbs for the selected patients with incomplete spinal cord injury. Results : The result was showed WISCI from 17 points to 17 points that is, no change occurred at all, and PCI from $161.01{\pm}103.06$ to $74.97{\pm}58.19$, some amount of reduction that is not statistically significant(p<.05). Regarding walking speed, it increased from $24{\pm}.07m/sec$ to. $61{\pm}.35m/sec$, that is statistically significant(p<.05), and motor score of lower limbs showed statistically significant increase like from $33.17{\pm}7.08$ to $37{\pm}5.14$(P<.05). Conclusion : The 4 evaluation categories seem to have shown differences due to an insufficient number of subjects, and short test term, and it seems the more diverse task-oriented walking exercises should be studied in the coming days.

The Design of Optimized Type-2 Fuzzy Neural Networks and Its Application (최적 Type-2 퍼지신경회로망 설계와 응용)

  • Kim, Gil-Sung;Ahn, Ihn-Seok;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1615-1623
    • /
    • 2009
  • In order to develop reliable on-site partial discharge (PD) pattern recognition algorithm, we introduce Type-2 Fuzzy Neural Networks (T2FNNs) optimized by means of Particle Swarm Optimization(PSO). T2FNNs exploit Type-2 fuzzy sets which have a characteristic of robustness in the diverse area of intelligence systems. Considering the on-site situation where it is not easy to obtain voltage phases to be used for PRPDA (Phase Resolved Partial Discharge Analysis), the PD data sets measured in the laboratory were artificially changed into data sets with shifted voltage phases and added noise in order to test the proposed algorithm. Also, the results obtained by the proposed algorithm were compared with that of conventional Neural Networks(NNs) as well as the existing Radial Basis Function Neural Networks (RBFNNs). The T2FNNs proposed in this study were appeared to have better performance when compared to conventional NNs and RBFNNs.

Insulation Aging Properties of Off-Line and On-Line High Voltage Motor Stator (정지중 및 운전중 고압전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1694-1696
    • /
    • 2001
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in six 6.6kV motors. These tests were conducted using a conventional partial discharge detector (PDD), turbine generator analyzer(TGA) and partial discharge analyzer(PDA). Off-line PD measurements were performed on six 6.6kV motors. PD magnitudes ranged from 740 pC to 5,100 pC at the normal line-to-ground voltage. Six 6.6kV motors have been equipped with eighteen 80pF epoxy-mica couplers(one per phase) on the motor terminal boxs. The PD pulse from sensors were measured with the TGA and PDA instruments on a normally operating motors. The PDD, TGA and PDA test results showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

The Detection of Partial Discharge Signal by the Measurement of an Electromagnetic Wave and Pattern Recognition Technique (전자파의 측정과 패턴인식 기법에 의한 부분방전 신호 검출)

  • Kim, Yeong-No;Kim, Jae-Cheol;Seo, In-Cheol;Jeon, Yeong-Jae;Kim, Gwang-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.276-283
    • /
    • 2002
  • This Paper Presents the method for detecting a partial discharge(PD) using an electromagnetic wave measured by an antenna. The various electromagnetic waves are measured in the laboratory and wavelet transform, which is provides a direct quantitative measure of spectral content in the time-frequency domain, are applied for identifying the property of electromagnetic waves. Also, the statistical method and self-organizing feature map(SOFM) are applied for the pattern recognition of electromagnetic waves. The proposed method is shown to be useful for detecting electromagnetic waves emitted for PD in test data.