• 제목/요약/키워드: partial test

검색결과 1,784건 처리시간 0.041초

유리단 국소의치의 기능 인상에 의한 연조직의 수직적 변위량에 관한 연구 (STUDY ON VERTICAL DISPLACEMENT OF SOFT TISSUE UNDER DISTAL EXTENSION PARTIAL DENTURE BASE BY FUNCTIONAL IMPRESSION)

  • 이광희;장익태
    • 대한치과보철학회지
    • /
    • 제21권1호
    • /
    • pp.59-66
    • /
    • 1983
  • Distal extension partial dentures are supported by both the relatively rigid teeth and the resilient mucosa. So impression techniques of residual alveolar ridge in case of distal extension partial denture have particular importance in order to broad distribution of the masticatory force. McLean recognized the need for recording the tissues supporting distal extension partial denture base in functional form to equalize the resilient and non-resilient support, and this was called functional impression. Many investigators proposed various techniques of the functional impression for a distal extension partial denture, but only a little studies were performed about displacement of soft tissue under distal extension partial denture base. The purpose of this study is to investigate the amount of vertical displacement of the soft tissue under distal extension partial denture base by different functional impression techniques. Impression techniques used were Z.O.P. Impression, Selective Tissue Placement Impression, Functional Relining Impression. Measurement of the vertical displacement of soft tissue were made with Depth Gauge and Measuring Platform. A Anatomic Impression was used as a control. The results were tested statistically using 3 way ANOVA and Scheffe test. The followings were the results obtained from this study. 1. The greatest amount of soft tissue displacement was observed in the center of the retromolar pad. 2. No significant differences were found between the crest of alveolar ridge and the buccal shelf area. 3. The greatest soft tissue displacement was observed in Functional Relining Impression using Iowa wax, and the least displacement was observed in Selective Tissue Placement Impression using murcaptan rubber base. 4. No significant differences were found between finger pressure and biting pressure in Z.O.P. Impression, but greater displacement was observed by biting pressure than finger pressure in Functional Reling Impression.

  • PDF

F급 플라이애쉬의 혼입방법을 달리한 콘크리트 특성에 관한 실험적 연구 (A Study on the Properties of the Concrete Containing Fly-ash of Class F According to the 3 Different Mixture Design)

  • 문종욱;유택동;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.191-198
    • /
    • 1999
  • The purpose of this study is investigating characteristics of the concrete containing Fly-ash according to different 4 mix design, that is, the first mix design is partial replace Fly-ash of cement, second is partial replace Fly-ash of cement and fine aggregate, third is partial replace Fly-ash of fine aggregate, fourth partial replacement of fine and coarse aggregate. For this purpose, selected test variables were water-binder ratio with two levels of 45%, 50%, and Fly-ash contents with four levels 0%, 10%, 20%, 30%, As the result of this study are as follow. 1) The result of mix design of a partial replacement of cement, the slump-flow value was appeared a promotive effect of viscosity. But in case of the over with Fly-ash 10% and the other mix design was not changed slump value. 2) The unit weight of the mixing rate with Fly-ash 0% was $1.875{\sim}1.884t/m^3$, the other mix design 10% over with Fly-ash was $1.846{\sim}1.615t/m^3$, the difference was appeared less about 15% than that. 3) In design, partial replace Fly-ash of fine aggregate, this compressive strength was appeared that the concrete age after 7 days was higher than in partial replacement of cement, therefore, the default of a concrete with Fly-ash, that is the earlier compressive strength was to lessen, was improved. 4) The thermal conductivity of the all mix design was $0.447{\sim}1.144kcal/mh^{\circ}C$, this value was as good as a lightweight aggregate concrete.

  • PDF

20례 슬통환자의 통증, 이환기간, 물리적 검사법과 MRI소견과의 비교 고찰 (Comparative Study between MRI and pain, duration, physical examination in 20 patients with knee joint pain)

  • 양명복;장병선;이대용;이승훈;황병천;박정운;국의석;이건목
    • Journal of Acupuncture Research
    • /
    • 제19권6호
    • /
    • pp.221-233
    • /
    • 2002
  • Background and Purpose : MRI(Magnetic Resonance Imaging) has become one of the most sensitive diagnostic tool no evaluate problems of the knee, because it enables us to identify not only osseous tissue but also soft tissues including muscle, fascia, tendon, ligament, meniscus and fat around the knee joint. Objective : To compare between MRI reading and pain, duration, physical examination in patients with pain of knee joint. Methods : 20 patients with pain of knee joint included in this study. This study researched pain-degree, duration, physical examination with pain of knee joint. Using MRI(Horizon Lx 1.0T-GE), we obtained the results. Results : 1. In the distribution of sex; Female rate was 80.0% and male rate was 20.0%. In the distribution of age, above sixty group was the largest group by each 55.0%. 2. In the distribution of MRI reading; 'Meniscus horm tear' was 70.0%, 'Osteoarthritis' was 55.5%, 'ACL partial tear' was 15.0%, 'Bone bruise at tibia, femur' was 15.0%. 3. Correlation between duration of pain and MRI reading showed that acute and subacute stage related various MRI reading, that chronic stage related 'Osteoarthritis' and 'Meniscus horn tear' by each 69.2%, 92.3%. 4. Correlation between pain and MRI reading showed that severe pain(GVI) related 'ACL partial tear, PCL partial tear' by each 100%, that mild pain(GII) related 'Osteoarthritis, Meniscus horn tear' by each 70.0%, 80.0%. 5. Correlation between physical examination and MRI reading showed that Drawer test related ACL partial tear by each 60.0%, that McMurray test related 'Meniscus horn tear' by each 75.0%. 6. Correlation between effect of treatment and MRI reading showed that 'Osteoarthritis, Meniscus horn tear' related good effect, that ACL partial tear related poor effect. Conclusions : These results suggest that acute and sever pain relate 'ACL partial tear, PCL partial tear', that chronic and mild pain related 'Osteoarthritis, Meniscus horn tear'. So it is responsibility to use MRI as a sensitive diagnostic tool in the knee problems.

  • PDF

구조분석과 테스트 가능도의 통합에 의한 부분스캔 설계 (A Partial Scan Design by Unifying Structural Analysis and Testabilities)

  • 박종욱;신상훈;박성주
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제26권9호
    • /
    • pp.1177-1184
    • /
    • 1999
  • 본 논문에서는 스캔플립프롭 선택 시간이 짧고 높은 고장 검출률(fault coverage)을 얻을 수 있는 새로운 부분스캔 설계 기술을 제안한다. 순차회로에서 테스트패턴 생성을 용이하게 하기 위하여 완전스캔 및 부분스캔 설계 기술이 널리 이용되고 있다. 스캔 설계로 인한 추가영역을 최소화 하고 최대의 고장 검출률을 목표로 하는 부분스캔 기술은 크게 구조분석과 테스트 가능도(testability)에 의한 설계 기술로 나누어 볼 수 있다. 구조분석에 의한 부분스캔은 짧은 시간에 스캔플립프롭을 선택할 수 있지만 고장 검출률은 낮다. 반면 테스트 가능도에 의한 부분스캔은 구조분석에 의한 부분스캔보다 스캔플립프롭의 선택 시간이 많이 걸리는 단점이 있지만 높은 고장 검출률을 나타낸다. 본 논문에서는 구조분석에 의한 부분스캔과 테스트 가능도에 의한 부분스캔 설계 기술의 장단점을 비교.분석하여 통합함으로써 스캔플립프롭 선택 시간을 단축하고 고장 검출률을 높일 수 있는 새로운 부분스캔 설계 기술을 제안한다. 실험결과 대부분의 ISCAS89 벤치마크 회로에서 스캔플립프롭 선택 시간은 현격히 감소하였고 비교적 높은 고장 검출률을 나타내었다.Abstract This paper provides a new partial scan design technique which not only reduces the time for selecting scan flip-flops but also improves fault coverage. To simplify the problem of the test pattern generation in the sequential circuits, full scan and partial scan design techniques have been widely adopted. The partial scan techniques which aim at minimizing the area overhead while maximizing the fault coverage, can be classified into the techniques based on structural analysis and testabilities. In case of the partial scan by structural analysis, it does not take much time to select scan flip-flops, but fault coverage is low. On the other hand, although the partial scan by testabilities generally results in high fault coverage, it requires more time to select scan flip-flops than the former method. In this paper, we analyzed and unified the strengths of the techniques by structural analysis and by testabilities. The new partial scan design technique not only reduces the time for selecting scan flip-flops but also improves fault coverage. Test results demonstrate the remarkable reduction of the time to select the scan flip-flops and high fault coverage in most ISCAS89 benchmark circuits.

대형 회전기의 절연진단결과와 경년 특성과의 상관관계에 관한 연구 (A Study on the Correlation between the Lapse of Time and Diagnostic Test Results of Large Rotating Machine Windings)

  • 김광화;조연옥;선종호;김영배;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.966-968
    • /
    • 1992
  • We have done the insulation diagnostic test of generators in domestic five power plants since 1987 and tested A.C. current increasing rate($\Delta$I), $\Delta$tan$\delta$ and partial discharge in generator winding insulation. This study is described the correlation between nondestructive result(A.C. current increasing rate, $\Delta$tan$\delta$ and partial discharge) and lapse of time in generators.

  • PDF

보육교사의 직무만족도와 소진 (Child Care Teacher's Job Satisfaction and Burnout)

  • 조성연
    • 한국생활과학회지
    • /
    • 제14권1호
    • /
    • pp.69-79
    • /
    • 2005
  • The purpose of this study is to investigate child rare teachers' job satisfaction in relation to their burnout and differences in their job satisfaction by demographic variables. Subjects of this study were 285 child care teachers in Chungnam province. They responded to 'Teachers' Work Satisfaction Scale' and 'Teachers' Burnout Scale.' The collected data were analyzed by one-way ANOVA, Pearson's partial correlation, stepwise multiple regression, $Scheff{\acute{e}}$ test for post hoc test, and Cronbach's a for reliability with SPSS PC program(10.0 version). The results are as follows: First, total job satisfaction was high in teachers with high school diploma and those married. Also, burnout level was high in teachers with high school diploma, those with more than 5 year, those married, and those over 40 years old. Second, the partial correlation coefficient of teachers' job satisfaction in relation to their burnout was -.52. Finally, teachers' burnout and demographic variables explained approximately 31% for total score of job satisfaction and $13{\sim}33%$ for subscales of it.

  • PDF

온라인 부분방전 감시 시스템 (On-Line System for Partial Monitoring Discharge)

  • 최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

솔라시뮬레이터의 램프뱅크 설계에 관한 연구 (A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR)

  • 백상화
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.

Epoxy 복합체의 내부 보이드에 따른 부분방전특성 (Partial Discharge Characteristics of Epoxy Composite due to Internal Void)

  • 김탁용;신종열;이준환;이덕진;홍진웅
    • 한국컴퓨터산업교육학회:학술대회논문집
    • /
    • 한국컴퓨터산업교육학회 2003년도 제4회 종합학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2003
  • Stability of inside power equipments are required for electron equipment in order to operate those safely. Also, the power circuits for these have been developing, but research of dielectric strength of power supply is insufficient. In this paper, for test insulation condition variation by void it is tested insulation characteristics variation, using $\phi-q-n$ distribution variation in partial discharge test.

  • PDF

Partial Scan Design based on Levelized Combinational Structure

  • Park, Sung-Ju
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권3호
    • /
    • pp.7-13
    • /
    • 1997
  • To overcome the large hardware overhead attendant in the full scan design, the concept of partial scan design has emerged with the virtue of less area and testability close to full scan. Combinational Structure has been developed to avoid the use of sequential test generator. But the patterns sifted on scan register have to be held for sequential depth period upon the aid of the dedicated HOLD circuit. In this paper, a new levelized structure is introduced aiming to exclude the need of extra HOLD circuit. The time to stimulate each scan latch is uniquely determined on this structure, hence each test pattern can e applied by scan shifting and then pulsing a system clock like the full scan but with much les scan flip-flops. Experimental results show that some sequential circuits are levelized by just scanning self-loop flip-flops.

  • PDF