Thermo-Mechanica1 Stress Analyses of Part with Coated Layer under Contact Load Using Partial Model (부분 모델을 이용한 접촉하중을 받는 코팅층이 있는 부재의 열적/기계적 응력해석)

  • 권영두;김석삼;신세현;추상우
    • Tribology and Lubricants
    • /
    • v.18 no.3
    • /
    • pp.228-234
    • /
    • 2002
  • Generally, space structures are subjected to severe situations, such as, sublimation, strong evaporation of lubricants, thermal stresses, high temperature gradients, irradiation, impacts by microscopic meteorites, and other factors. Recent]y, various kinds of coatings are applied to the parts under heavy contact stresses, in order to insure long wear-free lives and/or reduce friction coefficients. In space structures, molybdenum disulfide is using frequently. Moreover TiN, Al$_2$O$_3$, PTFE(Poly Tetra Fluor Ethylene) are introduced recently for space structure. In this part we are going to apply the partial model method, developed in reference[11] to analyze part with coated layer. In referencer[l1], we compute the reasonable size of partial model and aspect ratio. Using these data, we analyze the structures coated with TiN, Al$_2$O$_3$, PTFE under contact load, temperature and crack model . Beside, we consider the stress analysis under time dependent load and transient thermal effect.

Flame Characteristics of Diesel Spray in the Condition of Partial Premixed Compression Ignition (부분 예혼합 압축착화 조건에서 디젤분무의 화염특성)

  • Bang, Joong Cheol;Park, Chul Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.2
    • /
    • pp.24-31
    • /
    • 2012
  • Diesel engines exhaust much more NOx(Nitrogen Oxides) and PM(Particulate Matter) than gasoline engines, and it is not easy to reduce both NOx and PM simultaneously because of the trade-off relation between two components. This study investigated flame characteristics of the partial premixed compression ignition known as new combustion method which can reduce NOx and PM simultaneously. The investigation was performed through the analysis of the flame images taken by a high speed camera from the visible engine which is the modified single cylinder diesel engine. The results obtained through this investigation are summarized as follows; (1) The area of the luminous yellow flame was reduced due to the decrease of flame temperature and even distribution of temperature. (2) The darkish yellow flame zone caused by the shortage of the remaining oxygen after the middle stage of combustion was considerably reduced. (3) Since the ignition delay was shortened, the violent combustion did not occur and the combustion duration became shortened.

A Study of Partial Oxidation of Methane by Pd Catalyst - Effects of Reaction Temperature - (팔라듐 촉매의 메탄 부분산화에 관한 연구 - 반응온도에 따른 효과 -)

  • Lee, Taek-Hong;Mun, Yeong-Hwan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.244-249
    • /
    • 2004
  • Pd catalyst have been used in hydrogenation, oxidation, and low temperature combustion reaction. Recently, it has been candidated as a possible reagents in the partial oxidation of methanol reformers of the fuel cell. Pd catalysts, even though it is very precious and expensive, catalytic functioning is good, but it still need to be improved in the matter of durability and low catalytic activity after calcination. In this study, we synthesize the improved Pd catalyst and study their chemical functioning.

Residual gas analysis of small cavity for emissive flat panel display (미소체적을 갖는 평판표시소자용 패널내부의 잔류가스 분석)

  • 조영래;오재열;최정옥;김봉철;이병교;이진호;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The total pressure and partial pressure of small cavity for flat panel display have been successfully measured by using an ultra-high vacuum chamber with mass spectrometer. The total pressure in the panel was in the range of $10^{-6}$ Torr and the major partial pressure affecting increase in total pressure were those of Ar, $CH_4$and He. The baking temperature during evacuation process was very important for high-vacuum package, the total pressure and partial pressure of $CH_4$ were decreased as the increase of baking temperature.

  • PDF

A Study of Partial Carbonisation for the Development of Pitch Based Carbon Fibres

  • Aggarwal, R.K.;Bhatia, G.;Raman, V.;Saha, M.;Mishra, A.
    • Carbon letters
    • /
    • v.5 no.1
    • /
    • pp.23-26
    • /
    • 2004
  • A study of partial carbonisation of green pitch fibres to temperatures in the range of 500-$1000^{\circ}C$ was carried out on three precursors - a neat pitch and two polymer modified pitches, with a view to find out a suitable temperature at which the fibres acquire considerably improved toughness or handleability (compared to that in the green stage) for their subsequent processing into carbon fibres. A partial carbonisation temperature of 500-$600^{\circ}C$ has been identified to result in a remarkable improvement in the toughness/handleability of the fibres in all the three cases. However, from techno-economical considerations, the neat pitch appears to provide the best precursor system for the production of pitch based carbon fibres.

  • PDF

Temperature Dependence of PCBs in Urban Area of Seoul City (서울 대기 중 PCBs의 온도 의존성)

  • 여현구;최민규;천만영;김태욱;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.193-204
    • /
    • 2002
  • To investigate the relationships between the atmospheric concentrations of PCBs and temperature, quantity of both parameters was performed at an urban site in Korea from July 1999 to January 2000. The strength of correlations between total PCB and temperature was found to be significant (r = 0.752, p < 0.001). It hence indicates that total PCB contents were affected sensitively by temperature change during the sampling period. The ratio of PCB homologs and Deca-CB(PCB 209) also behaved quite similarly to the change of temperature (r>0.60, p<0.05). This may be inferable with the progress of the gas/particle partitioning to the gas phase, especially for fri-and tetra-CBs. Because they have high vapor pressure, they generally exist in the gas phase. The Clausius-Clapeyron equation was applied to the atmospheric PCB data, relating PCB partial vapor pressure to inverse temperature. This may essentially represent the temperature-controlled transition between condensed phase and atmospheric gas phase. The slopes of the resulting plot with International Council for the Explanation of the Seas (ICES) congener ranged from -2810 to -5887, with significantly steep slope and $R^2$(p< 0.005) It was inferred that the PCB atmospheric concentration was also affected by change in the surrounding conditions such as soil, lakes and trees.

A study on inhomogeneity of YBCO Coated Conductors using Low-temperature Scanning Laser Microscopy (LTSLM) (저온 주사 레이저 현미경(LTSLM)을 이용한 YBCO 초전도 선재의 불균질성 연구)

  • Park, S.K.;Kim, J.M.;Lee, S.B.;Kim, S.H.;Kim, G.Y.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.72-77
    • /
    • 2009
  • Low temperature scanning laser microscopy (LTSLM) can be used for a two-dimensional display of bolometric response arising from the localized excitation of a sample by the focused laser beam. In this study, the distribution of critical temperature ($T_c$) and critical current density ($J_c$) in YBCO coated conductor were analyzed using LTSLM. For improving the temperature stability, we have modified the system into a double-shielding type. Through the modification, the temperature stability was successfully improved from ${\pm}10mK\;to\;{\pm}2mK$. The superconducting properties of YBCO coated conductors were measured for the sample of a narrow bridge type using wet etching process. The spatial non-uniformity of the ac voltage response, ${\delta}V(x)$, which is proportional to ${\partial}\rho(x,J_B)/{\partial}T$ in the transition temperature region could be observed and displayed in a two-dimensional image.

  • PDF

Real Effect of pH on CIE L*, a*, and b*, of Loins during 24 h Chilling of Beef Carcasses

  • Min, J.S.;Kim, I.S.;Yoon, Y.T.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.2
    • /
    • pp.279-282
    • /
    • 2002
  • Twenty six male Hanwoo (Korean cattle) carcasses were measured for pH, temperature and instrumental color changes of loins during 24 h post-mortem carcass chilling at $4^{\circ}C$ in the cooler. The average internal temperature of loins was about $5^{\circ}C$ after 24 h of chilling, and with the exclusion of those with an ultimate pH>6.0 (dark-cutters), the average pH value was 5.5. When all carcasses were considered for the partial correlation coefficient between color and pH, with the temperature effect excluded, CIE $L^*$, $a^*$ and $b^*$ seemed to be affected significantly by pH during chilling process (p<0.001). However, when carcasses with dark-cutting condition were excluded, the correlation coefficients were much lower. In contrast, when the partial correlation coefficients between color and temperature, excluding the effect of pH on them, were analyzed, the relationship between color and temperature did not change much after values of DFD (dark, firm, dry) beef were excluded. The results suggested that the known interrelationship of color and pH in chilled beef loins be mainly due to the influence of temperature on pH and color.

The Study on Temperature Measurement of Warm Needling Using Stainless Steel Needle and Gold Needle (금침과 스테인레스침을 이용한 온침에서의 부위별 온도측정 연구)

  • Yeo, Sujung
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.178-184
    • /
    • 2013
  • Objectives : The warm needling technique is the method combining the effects of acupuncture needle with those of moxibustion. We need to standardize the characteristics of the warm needling technique, in order to get more systematic and objective results in operation and effects and then get more clinical abilities in these fields. Methods : In this study, using labview system on the warm needling technique, we measured and compared partial temperature changes according to the kind of needle. We studied relations of moxa cones of various sizes with the peak combustion temperature. Results and Conclusions: When we measured the warm needling's partial temperature, temperature measured at 1 and 2 cm below the head, according to the kind of needle, gold needle got the higher result on the peak than SS304 stainless steel needle. In the case of combustion of the moxa cones, cones weighing 0.4 g and 0.8 g, respectively, and the apex ignition method with gold needle showed the higher result than the apex ignition method with stainless steel needle, when we measured the effective stimulus time at 2 cm below the head and the mean temperature during the effective stimulus time. Although more research to standardize the characteristics of the warm needling technique will be needed, we suggest, according to these results, that warm needling of gold needle combined with moxa cone of 0.4 or 0.8 g is effective.

Effects of La addition to Ni/$CeO_2$ Methane Partial Oxidation Catalysts (메탄 부분산화반응 Ni/$CeO_2$ 촉매에 LA 첨가의 영향)

  • Cheon, Han-Jin;Shin, Ki-Seok;Ahn, Sung-Hwan;Yoon, Cheol-Hun;Hahm, Hyun-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.29-36
    • /
    • 2010
  • The effects of La addition to Ni/$CeO_2$ methane partial oxidation catalysts were investigated. Catalysts were prepared by the impregnation and urea methods. In the preparation of catalysts, La content was changed from 1 wt% to 3wt%. Catalysts that contain 2wt% La showed the highest methane conversion of about 80% and CO selectivity of 84% and $H_2$ selectivity of 70%. This result may be stemmed from that, when La content is 2wt%, a fluorite oxide-type structure is well formed and carbon deposition is also decreased. Among the catalysts, 2.5wt% Ni/Ce(La)Ox showed the highest catalytic activity. From the experiment of changing reaction temperature with 2.5wt% Ni/Ce(La)Ox catalyst, it was found that the optimum reaction temperature is $750^{\circ}C$ and at this temperature methane conversion was about 90%, CO and $H_2$ selectivities were 94 and 80%, respectively.