Clinical experience in managing temporomandibular joint ankylosis: five-year appraisal in a Nigerian subpopulation

  • Braimah, Ramat;Taiwo, Abdurrazaq;Ibikunle, Adebayo;Oladejo, Taoreed;Adeyemi, Mike;Adejobi, Francis;Abubakar, Siddiq
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.3
    • /
    • pp.112-119
    • /
    • 2018
  • Objectives: Temporomandibular joint ankylosis (TMJA) is a joint pathology caused by bony and/or fibrous adhesion of the joint apparatus, resulting in partial or total loss of function. Materials and Methods: This is a retrospective study conducted between 2012 and 2016 in the northwest region of Nigeria. The data retrieved includes gender, age, etiology of ankylosis, duration of ankylosis, laterality of ankylosis, type of imaging technique, type of airway management, types of incision, surgical procedure, mouth opening, interpositional materials used, and complications. Results were presented as simple frequencies and descriptive statistics. Results: Thirty-six patients with TMJA were evaluated during the study period. There were 21 males (58.3%) and 15 females (41.7%), yielding a male:female ratio of 1.4:1. The patients' age ranged from 5 to 33 years with $mean{\pm}standard$ deviation ($13.8{\pm}6.6years$). Thirty-five cases (97.2%) were determined to be true/bony ankylosis, while only 1 case (2.8%) was false/fibrous ankylosis. Most of the TMJA cases (16 cases, 44.4%) were secondary to a fall. In our series, the most commonly utilized incision was the Bramley-Al-Kayat (15 cases, 41.7%). The mostly commonly performed procedures were condylectomies and upper ramus ostectomies (12 cases each, 33.3%), while the most commonly used interpositional material was temporalis fascia (14 cases, 38.9%). The complications that developed included 4 cases (11.1%) of severe hemorrhage, 1 case (2.8%) of facial nerve palsy, and 1 case (2.8%) of re-ankylosis. Conclusion: Plain radiographs, with their shortcomings, still have significant roles in investigating TMJA. Aggressive postoperative physiotherapy for a minimum of 6 months is paramount for successful treatment.

Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases (복합적인 전신질환이 있는 안면마비 환자의 양악 자성 피개의치 수복 증례)

  • Ko, Eunjin;Ahn, Sujin;Lee, Sukwon;Park, Sujung;Lee, Richard Sungbok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • As dental implant treatment becomes popular for both partial and complete edentulous patients, old people with complex systemic diseases also tend to prefer implant-assisted-overdenture or implant-supported-fixed prostheses to conventional complete denture. In this case, 77-year-old female who was on medication for hypertension and osteoporosis and paralyzed on right side due to stroke visited for implant-assisted-overdenture on lower jaw. After oral and radiographic examination, root-assisted magnet overdenture on upper jaw and implant-assisted magnet overdenture on lower jaw are planned. Consequently, overdentures using self-adjusting magnetic attachment(SA) system on both jaws resulted in recovering satisfying function and retention, which is enable to insert and remove with only one hand.

Porcine Somatotropin Improves the Efficiency of Digestible Protein Use for Protein Deposition by Growing Pigs

  • Lee, K.U.;Boyd, R.D.;Austic, R.E.;Ross, D.A.;Beermann, D.H.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.7
    • /
    • pp.1096-1103
    • /
    • 1999
  • A study was conducted to clarify the impact of recombinant porcine somatotropin (pST) on the efficiency of absorbed nitrogen use for protein deposition in growing pigs. Three levels of dietary crude protein (9.0, 11.5, 14.0% CP) were used. Each had either a sub-optimum or near optimum lysine: CP concentration (Low-lysine, 3.8 g/100 g CP and High-lysine, 5.5 g/100g CP) in order to achieve different metabolic efficiencies for nitrogen deposition (ca. 45 vs. 60%). Twelve crossbred female pigs $(59{\pm}4kg\;BW)$ were placed in metabolism cages and fitted with bladder catheters. Each pig received an excipient injection daily for the first 10-d, a pST (5 mg/d) injection for the second 10-d, and then excipient for the last 10-d. Pigs were randomly assigned to one of six dietary treatments (2 pigs/diet) and fed 4 times per d at $92g/kg\;BW^{0.75}$ $(3{\times}maintenance)$. Means for the excipient period were compared to means for the pST period. Urinary nitrogen (N) output declined in pST-treated pigs (p<0.01) irrespective of dietary protein content or lysine level. Nitrogen retention increased by an average of 11% (p<0.01) with pST treatment (726 vs. $803mg\;N/kg^{0.75}\;BW/d$). Forty-eight percent of the absorbed N was retained with Low-lysine diets, but this increased to 53% with pST injection (+11%, p<0.01). Pigs fed High-lysine diets retained 62% of absorbed N which increased to 69% with pST (+11% p<0.01). the addition of lysine improved N use by 27% (High vs. Low, p<0.01), but the effect of lysine and pST was additive (+40%). Therefore, pST improves N retention and the efficiency of apparently absorbed N use in growing pigs (>60kg). It does so with diets having the potential for either low or high efficiencies of N use (48% and 62%). More work is needed to determine if the partial efficiency of N use improves in direct proportion to pST dose since the improvement in protein deposition is a function of pST dose.

Edge Feature Extract CBIRS for Car Retrieval : CBIRS/EFI (차량 검색을 위한 측면 에지 특징 추출 내용기반 검색 : CBIRS/EFI)

  • Koo, Gun-Seo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.75-82
    • /
    • 2010
  • The paper proposed CBIRS/EFI with contents based search technique using edge feature information of the object from image information of the object which is uncertain. In order to search specially efficiently case of partial image information of the object, we used the search technique which extracts outline information and color information in feature information of object. In order to experiment this, we extracted side edge feature information of the vehicle for feature information of the object after capture the car image of the underground garage. This is the system which applies a contents base search by the result which analyzes the image which extracts a feature, an original image to search and a last similar measurement result. This system compared in FE-CBIRS systems which are an existing feature extraction contents base image retrieval system and the function which improves the accuracy and an effectiveness of search rate was complemented. The performance appraisal of CBIRS/EFI systems applied edge extraction feature information and color information of the cars. And we compared a color feature search time, a shape characteristic search time and a search rate from the process which searches area feature information. We extracted the case 91.84% of car edge feature extraction rate. And a average search time of CBIRS/EFI is showing a difference of average 0.4-0.9 seconds than FE-CBIRS from vehicle. color search time, shape characteristic search time and similar search time. So, it was proven with the fact that is excellent.

Patch Reconstruction with Radial Forearm Free Flap of Hypopharyngeal Cancer Using the Narrow Strip Pharynageal Wall (소폭의 잔존 하인두벽을 이용한 첩포형 전완유리 피판 인두 재건술)

  • Jeong, Hii Sun;Lee, Won Jai;Lew, Dae Hyun;Rah, Dong Kyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.407-412
    • /
    • 2006
  • Purpose: Various attempts of reconstruction for pharyngoesophageal defects after ablative surgery have been made to restore the function of the pharyngoesophagus. A fabricated tubed radial forearm free flap or free jejunal free flap was used when the width of remnant pharyngeal wall was less than 50% of the normal width. However there are many disadvantages such as stricture, saliva leakage and fistula formation on tubed radial forearm free flap. The jejunal free flap has the problem such as short pedicle, poor tolerance of ischemic time, wet voice and delayed transit of swallowed food due to the uncoordinated contraction. The authors studied the utility of patch-type radial forearm free flap using the remnant posterior pharyngeal wall of the hypopharynx. Methods: Retrospective reviews in Severance Hospital were made on 25 patients who underwent reconstruction surgery with patched radial forearm free flap because of the hypopharyngeal cancer between 1996 and 2005. The patients of Group I had the narrow posterior pharyngeal wall and its width was less than 3centimeters after the tumor was resected. Those of Group II had the partial pharyngectomy and the width of the remnant pharynx was larger than 3 centimeters. Results: Seven patients belonged to the group I and the flap of this group had 100% survival rate. One case of fistula and no swallowing discomfort due to stricture was reported. The Group II including 18 patients also had the 100% flap survival rate. Neither fistula nor stricture was seen but the lower diet grade was checked. Conclusion: The patch type radial forearm free flap using the remnant pharyngeal wall have the advantage of the radial forearm free flap, and furthermore this flap is the safe reconstructive method even if the width of the remnant pharyngeal wall is less than 30% of that of normal pharynx.

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

The properties of Al-doped ZnO films deposited with RF magnetron sputtering system in various H2/(Ar + H2) gas ratios (RF 마그네트론 스퍼터링 방법을 사용해 증착된 Al이 도핑 된 ZnO 박막의 H2/(Ar + H2) 가스 비율에 따른 특성)

  • Kim, Jwa-Yeon;Han, Jung-Su
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.3
    • /
    • pp.122-126
    • /
    • 2012
  • The properties of Al-doped ZnO (AZO) films were investigated as a function of $H_2/(Ar+H_2)$ gas ratio using an AZO (2 wt% $Al_2O_3$) ceramic target in a radio frequency (RF) magnetron sputtering system. The deposition process was done at $200^{\circ}C$ and in $2{\times}10^{-2}$ Torr working pressure and with various ratios of $H_2/(Ar+H_2)$ gas. During the AZO film deposition process, partial $H_2$ gas affected the AZO film characteristics. The electron resistivity (${\sim}9.21{\times}10^{-4}\;{\Omega}cm$) was lowest and mobility (${\sim}17.8\;cm^2/Vs$) was highest in AZO films when the $H_2/(Ar+H_2)$ gas ratio was 2.5 %. When the $H_2/(Ar+H_2)$ gas ratio was increased above 2.5 %, the electron resistivity increased and mobility decreased with increasing $H_2/(Ar+H_2)$ gas ratio in AZO films. The carrier concentration increased with increasing $H_2/(Ar+H_2)$ gas ratio from 0 % to 7.5 %. This phenomenon was explained by reaction of hydrogen and oxygen and additional formation of oxygen vacancy. The average optical transmission in the visible light wavelength region over 90 % and an orientation of the deposition was [002] orientation for AZO films grown with all $H_2/(Ar+H_2)$ gas ratios.

AN EXPERIMENTAL STUDY ON THE TISSUE RESPONSE OF THE TEMPOROMANDIBULAR JOINT IN UNILATERAL MANDIBULAR EDENTULISM (하악편측치아의 결손에 따른 악관절의 조직반응에 대한 연구)

  • Paik, Hyee-Seon;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.285-294
    • /
    • 1991
  • The human temporomandibular joint as a ginglymoarthrodial one has much in common with the other synovial joints of the body, but it does possess an unique charachteristic in that it must accomodate the various occlusal relations of dentition during an end point of closure. For that reason, the movement of the condyle in the temporomandibular joint is susceptible to influences from the nature of occlusion. Undue loading to the temporomandibular joint can be applied on the occasion of premature contacts in centric relation, balancing side interferences, change of occlusal surfaces due to excessive attrition, loss of tooth. Such occlusal disharmonies in association with the systemic and emotional factors may give rise to the temporomandibular disorder. On the other hand, the changes of occlusal patterns in the growing body can also have an effect on the growth of the temporomandibular joint through the alterations of functional stresses. The purpose of this study was to observe histopathologic response of the temporomandibular joint in unilateral chewing on one side exclusively for 10 months. Three dogs showing normal masticatory function were chosen. One dog aged about 12 months was for control, two dogs for experimental specimens were about 12 and 18 months old respectively. For chewing on the left side only, unilateral lower right premolar and molar were extracted in two experimental specimens. And then three dogs were sacrificed 10 months later. Frontal histologic sectioning of joints were done for the observation of the effects of one-side chewing. 24 specimens from three dogs were obtained and fixed in 10% formalin and routinly processed with H-E staining for histologic examination. The light microscopic findings were interpretated as follows: 1. Experimental specimen 1 aged about 22 months: In comparison with control and right non-chewing side, the proliferative and hypertrophic zone were increased at the mesial and lateral part of left chewing side condyle. There was no change of the articular tissue of temporal bone. 2. Experimental specimen 2 aged about 28 months: The articular tissues of adult joint were observed. The differences between the chewing and non-chewing side were not seen in the articular tissues of condyle and temporal bone.

  • PDF

Stochastic response of suspension bridges for various spatial variability models

  • Adanur, Suleyman;Altunisik, Ahmet C.;Soyluk, Kurtulus;Dumanoglu, A. Aydin
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.1001-1018
    • /
    • 2016
  • The purpose of this paper is to compare the structural responses obtained from the stochastic analysis of a suspension bridge subjected to uniform and partially correlated seismic ground motions, using different spatial correlation functions commonly used in the earthquake engineering. The spatial correlation function employed in this study consists of a term that characterizes the loss of coherency. To account for the spatial variability of ground motions, the widely used four loss of coherency models in the literature has been taken into account in this study. Because each of these models has its own characteristics, it is intended to determine the sensitivity of a suspension bridge due to these losses of coherency models which represent the spatial variability of ground motions. Bosporus Suspension Bridge connects Europe to Asia in Istanbul is selected as a numerical example. The bridge has steel towers that are flexible, inclined hangers and a steel box-deck of 1074 m main span, with side spans of 231 and 255 m on the European and Asian sides, respectively. For the ground motion the filtered white noise model is considered and applied in the vertical direction, the intensity parameter of this model is obtained by using the S16E component of Pacoima Dam record of 1971 San Fernando earthquake. An analytically simple model called as filtered white noise ground motion model is chosen to represent the earthquake ground motion. When compared with the uniform ground motion case, the results obtained from the spatial variability models with partial correlation outline the necessity to include the spatial variability of ground motions in the stochastic dynamic analysis of suspension bridges. It is observed that while the largest response values are obtained for the model proposed by Harichandran and Vanmarcke, the model proposed by Uscinski produces the smallest responses among the considered partially correlated ground motion models. The response values obtained from the uniform ground motion case are usually smaller than those of the responses obtained from the partially correlated ground motion cases. While the response values at the flexible parts of the bridge are totally dominated by the dynamic component, the pseudo-static component also has significant contributions for the response values at the rigid parts of the bridge. The results also show the consistency of the spatial variability models, which have different characteristics, considered in this study.

EST Analysis system for panning gene

  • Hur, Cheol-Goo;Lim, So-Hyung;Goh, Sung-Ho;Shin, Min-Su;Cho, Hwan-Gue
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2000.11a
    • /
    • pp.21-22
    • /
    • 2000
  • Expressed sequence tags (EFTs) are the partial segments of cDNA produced from 5 or 3 single-pass sequencing of cDNA clones, error-prone and generated in highly redundant sets. Advancement and expansion of Genomics made biologists to generate huge amount of ESTs from variety of organisms-human, microorganisms as well as plants, and the cumulated number of ESTs is over 5.3 million, As the EST data being accumulate more rapidly, it becomes bigger that the needs of the EST analysis tools for extraction of biological meaning from EST data. Among the several needs of EST analyses, the extraction of protein sequence or functional motifs from ESTs are important for the identification of their function in vivo. To accomplish that purpose the precise and accurate identification of the region where the coding sequences (CDSs) is a crucial problem to solve primarily, and it will be helpful to extract and detect of genuine CD5s and protein motifs from EST collections. Although several public tools are available for EST analysis, there is not any one to accomplish the object. Furthermore, they are not targeted to the plant ESTs but human or microorganism. Thus, to correspond the urgent needs of collaborators deals with plant ESTs and to establish the analysis system to be used as general-purpose public software we constructed the pipelined-EST analysis system by integration of public software components. The software we used are as follows - Phred/Cross-match for the quality control and vector screening, NCBI Blast for the similarity searching, ICATools for the EST clustering, Phrap for EST contig assembly, and BLOCKS/Prosite for protein motif searching. The sample data set used for the construction and verification of this system was 1,386 ESTs from human intrathymic T-cells that verified using UniGene and Nr database of NCBI. The approach for the extraction of CDSs from sample data set was carried out by comparison between sample data and protein sequences/motif database, determining matched protein sequences/motifs that agree with our defined parameters, and extracting the regions that shows similarities. In recent future, in addition to these components, it is supposed to be also integrated into our system and served that the software for the peptide mass spectrometry fingerprint analysis, one of the proteomics fields. This pipelined-EST analysis system will extend our knowledge on the plant ESTs and proteins by identification of unknown-genes.

  • PDF