• Title/Summary/Keyword: partial changes

Search Result 805, Processing Time 0.026 seconds

Prediction of Initial Design Parameter of Rectangular Shaped Mold Spring Using Finite Element Method (유한요소법을 이용한 사각단면 금형스프링의 초기 설계변수 예측)

  • Lee, H.W.
    • Transactions of Materials Processing
    • /
    • v.20 no.6
    • /
    • pp.450-455
    • /
    • 2011
  • This paper presents an inverse design methodology for the cross section geometry of mold spring with a rectangular cross section as the starting material for a coiling process. The cross-sections of mold springs are universally rectangular, as the parallel sides minimize the possibility of failure under high service loads. Pre-coiled wires are initially designed to have a trapezoidal cross section, which becomes a rectangle by the coiling process. This study demonstrates a numerical exercise to predict changes in the sectional geometry in spring manufacture and to obtain the initial cross section which becomes the exact rectangle desired from the manufacturing process. Finite element analysis was carried out to calculate the sectional changes for various mold springs. Geometrical parameters were the widths at inner and outer radii, the inner and the outer corner radii, and the height. A partial least square regression analysis was carried out to find the main contributing factors for deciding initial design values. The height and the width mainly affected various initial parameters. The initial width at the inner radius was mostly affected by various specification parameters.

Clinical gap changes after porcelain firing cycles of zirconia fixed dentures

  • Bugurman, Bugurman Burcu;Turker, Sebnem Begum
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.177-184
    • /
    • 2014
  • PURPOSE. The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS. A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS. No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values ($59.54{\mu}m$) were significantly lower than the initial marginal area values ($68.68{\mu}m$)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION. The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.

EFFECT OF SECONDARY HEAT TREATMENT ON DIMENSIONAL CHANGES OF ACRYLIC RESIN PARTIAL DENTURE BASE (2차 가열에 의한 국소의치상의 변형에 관한 실험적 연구)

  • Jang, Byung-Gun;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.193-211
    • /
    • 1989
  • The purpose of this study was to investigate the effect of secondary heat treatment on dimensional changes of acrylic resin partial denture base. For this study, 6 specimens were made: 2 groups of 2 specimens, each was treated with $125^{\circ}C$ dry heat and glycerine heat for 3 minutes, and the others were prepared for control group. The change of the internal diameter of specimens were measured after 3 hrs, 1 day, 1 week, 2 weeks, 4 weeks by three-dimensional space analyzer. The results were as follows : 1. All of the acrylic resin denture bases showed tissue ward thermal contraction. 2. Thermal contraction of the mesial area reinforced with metal framework was lesser than that of the distal area without metal framework. 3. Thermal contraction of the lingual flange reinforced with metal framework occured more slowly than that of the buccal flange without the metal framework. 4. The thermal contraction of dry heat treated acrylic resin base, compared to glycerine heat group, was moderately greater and occurred acutely.

  • PDF

A Study on the Homostatic Effects of Guipitang and Guipitangjiaweifang Extracts in Experimental Animals (歸脾湯 및 歸脾湯加味方의 止血效果에 관한 實驗的 硏究)

  • Park, In-ki;Kim, Kyung-jun
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.1
    • /
    • pp.63-76
    • /
    • 2003
  • This Experiment was conducted to investigate the hemostatic effects of Guipitang and Guipitangjiaweifang. For this purpose, the effects of the crude extracts on the platelet count. prothrombin time, fibrinogen level and partial prothromboplastin time were estimated. The rats were divided into normal group, control group and experimental group. Control group was administrated normal saline and experimental group was divided into Sample 1 (Guipitang) and Sample 2 (Guipitangjiaweifang). The results obtained were as follows : 1. The platelet count was significantly increased in both of two samples as compared with the control group. 2. The prothrombin time was significantly shortened in case of Sample 2. however there were no significant changes in case of Sample 1 as compared with the control group. 3. The fibrinogen level was significantly increased in case of Sample 1. however there were no meaningful changes in case of Sample 2 as compared with the control group. 4. The partial prothromboplastin time was significantly shortened in both of two samples as compared with the control group. According to above results. it is supposed that Guipitang and Guipitangjiaweifang have the hemostatic effects in experimental animals.

  • PDF

An Analysis of the Impact of Changes in Kimchi Imports on the Korean Kimchi Industry (김치 수입량 변화가 국내 김치산업에 미치는 영향 분석)

  • Kim, In-Seck;Jeong, Seon-Hwa;Jeong, Ga-yeon
    • Korean Journal of Organic Agriculture
    • /
    • v.30 no.2
    • /
    • pp.151-170
    • /
    • 2022
  • The demand for commercial kimchi has increased continuously for the past 20 years due to the increase in eating out demand. Although Korean kimchi industry has expanded significantly, it is still small and a large portion of domestic demand is dependent on Chinese kimchi. Chinese kimchi imports has markedly increased over the last 20 years. However, kimchi imports from China in 2021 significantly reduced due to the recently released video showing a naked man making Kimchi. Korean government has decided to apply HACCP to all imported Kimchi from October 2021 in order to improve the safety of imported kimchi. This study analyzed the effect of changes in the amount of kimchi imports due to the introduction of HACCP on the kimchi industry by using a dynamic partial equilibrium model. According to the analysis result, if imports decreased by 20% compared to the Baseline, domestic kimchi production increased from 1.8% to a maximum of 4.8%, but kimchi consumption decreased from 3.1% to 5.2%. In particular, consumption away from home decreased from 3.3% to 5.7%. It is expected that the results of this study would be used as useful data in the decision-making process of market participants and policy makers related to the kimchi industry.

TIME-DEPENDENT DEFORMATION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Pae Ahran;Jeong Mi-Sook;Kim Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.717-726
    • /
    • 2005
  • Statement of problem. One of the common problems of provisional crown and fixed partial denture materials is that when they are subjected to constant loads for a long period of time, they exhibit a dimensional change (creep). Purpose. The aim of this study was to investigate the viscoelastic behaviour of polymer-based provisional crown and fixed partial denture materials with time at constant compressive load. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Temphase, Luxatemp) and one monomethacrylate-based material (Trim) were selected. Dimensional changes of the specimens were recorded by a LVDT to evaluate their viscoelastic behavior and creep strain. For all specimens, two loading procedures were used. At first, static compressive stress of 4 MPa was applied for 30 minutes and followed by 1 hour of strain recovery. Then, after 24 hours of water storage, the specimens were loaded again. The creep values between materials were statistically analyzed using one-way ANOVA and multiple comparison $Scheff\acute{e}$ test. Independent samples t-test was also used to identify the difference of creep strain between first and secondary loading conditions at the significance level of 0.05. Results. Following application of the first loading, Trim showed the highest maximum creep strain (32.7%) followed by Luxatemp, Protemp 3 Garant and Temphase, with values of 3.78%, 2.86% and 1.77%, respectively. Trim was significantly different from other materials (P<0.05), while there were no significant differences among Luxatemp, Protemp 3 Garant and Temphase (P>0.05). The highest recovery and permanent set of Trim, were significantly different from those of others (P<0.05). At the secondary loading of the dimethacrylate-based materials, creep deformation, recovery and permanent set decreased and the percentage of recovery increased, while in Trim, all values of the measurements increased. This result showed that the secondary loading at 24 hours produced a significant creep magnitude. Conclusion. The dimethacrylate-based provisional crown and fixed partial denture materials showed significantly higher creep resistance and lower deformation than the monomethacrylate-based material. Thus, monomethacrylate-based materials should not be used in long-term stress-bearing situations.

Effects of flow variation in the first stage nozzle on the performance of a partial arc admission in a steam turbine (증기터빈 1단 노즐의 조속현상이 터빈성능에 미치는 영향)

  • Yoon, In-Soo;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.60-65
    • /
    • 2008
  • Power plant industry has been developed at high-capacity, high-technology, and innovation. Steam turbine became the most useful equipment that dominate more than 50% of all the world electricity production. And developed new materials of the turbine blade and extended length of the turbine last blade brought reform in steam turbine performance upgrade. In this paper, when do partial load driving in high-capacity steam turbine, optimum driving method found whether there is something. In operating steam turbine, there is a lot of loss from secondary wake and throttle of the 1st stage nozzle by the biggest leading factor that load fluctuation affects in high-pressure steam turbine performance. Effect of internal efficiency by 1 stage nozzle is the biggest here, but here fluid flow and flow analysis were not yet examined closely definitely. So, Analyzed design data and acceptance performance test result to applying subcritical pressure drum type 560 MW, supercritical-pressure once through type 500 MW, and 800 MW steam turbines actually. In conclusion, at partial load driving, partial arc admission(PAA) is more efficient than full arc admission(FAA) efficiency. This is judged by because increase being proportional with gross energy of stream that is pressure - available energy if pressure of stream that is flowed in to the turbine increases, available energy becomes maximum and turbine efficiency improves. Therefore, turbine performance is that preview that first stage performance fell if decline is serious in partial load because first stage performance changes according to load.

  • PDF

Nonlinear impact of temperature change on electricity demand: estimation and prediction using partial linear model (기온변화가 전력수요에 미치는 비선형적 영향: 부분선형모형을 이용한 추정과 예측)

  • Park, Jiwon;Seo, Byeongseon
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.5
    • /
    • pp.703-720
    • /
    • 2019
  • The influence of temperature on electricity demand is increasing due to extreme weather and climate change, and the climate impacts involves nonlinearity, asymmetry and complexity. Considering changes in government energy policy and the development of the fourth industrial revolution, it is important to assess the climate effect more accurately for stable management of electricity supply and demand. This study aims to analyze the effect of temperature change on electricity demand using the partial linear model. The main results obtained using the time-unit high frequency data for meteorological variables and electricity consumption are as follows. Estimation results show that the relationship between temperature change and electricity demand involves complexity, nonlinearity and asymmetry, which reflects the nonlinear effect of extreme weather. The prediction accuracy of in-sample and out-of-sample electricity forecasting using the partial linear model evidences better predictive accuracy than the conventional model based on the heating and cooling degree days. Diebold-Mariano test confirms significance of the predictive accuracy of the partial linear model.

Arthroscopic Treatment for Meniscal Cyst (관절경을 이용한 반월상연골 낭종의 치료)

  • Min, Byoung-Hyun;Lee, Weon Ik;Choi, Seung Joon;Kang, Shin Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.141-146
    • /
    • 1998
  • Recent studies suggest that most meniscal cysts can be treated surgically by arthroscopic management of the meniscal tear and arthroscopic cyst evacuation. But arthroscopic cyst decompression may sacrifice a substantial amount of meniscal tissue that is not torn in order to expose the "stalk" of the cyst. Nowadays, the trend is changing as preserving the involved meniscus to prevent from inevitable degenerative changes after meniscectomy. The purpose of this report is to describe a new surgical technique that minimizes loss of meniscal tissue in hopes of maximizing residual meniscal function. We experienced 10 patients with meniscal cysts that were consisted of four lateral cysts and six medial cysts. Menisci were torn in all cases. Arthroscopic partial meniscectomy and decompression of cysts were performed in 9 cases, and arthroscopic partial meniscectomy and open cystectomy in 1 case. The procedures were consisted of injection of the methylene blue into the cyst, partial meniscectomy of the meniscal tear until the dye was seen in orifice of the cyst, and decompression of cyst through cystic opening. This article serves to confirm the relationship between torn menisci and cysts, to re-evaluate the occurrence ratio of the meniscal cyst on the medial to lateral meniscus, and to assess the efficacy of arthroscopic partial meniscectomy and decompression of cyst as a potentially meniscal sparing procedure.

  • PDF

Two Clinical Cases of Active Release Technique with Koeran Medicine Treatment for Supraspinatus Tendon Partial Tear (능동이완기법(active release technique)을 병행한 한방치료로 호전된 극상근건 부분 파열 호전 2례)

  • Lee, Sung-Joon;Park, Jae-Hyun;Nam, Su-Hyeon;Kang, Jun-Hyuk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.1
    • /
    • pp.89-101
    • /
    • 2014
  • Objectives : The purpose of this study is to report the effect of Korean medicine treatment combined with active release technique on supraspinatus tendon partial tear. Methods : Two patients with supraspinatus tendon partial tear were treated by Korean medicine treatment in combination with active release technique. Visual analog scale(VAS), range of motion(ROM) were used to measure changes during treatment. Results : After treatment, shoulder pain and limited range of motion were improved significantly. Conclusions : Korean medicine treatment in combination with active release technique is proved to be helpful to improve the symptoms of the supraspinatus tendon partial tear patients. And, further studies will be needed.

  • PDF