• 제목/요약/키워드: paper fire

검색결과 2,245건 처리시간 0.027초

선박의 거주구역 화재시 연기거동 및 온도변화에 관한 시뮬레이션 연구 (A Simulation Study on Distributions of Smoke and Temperature in Accommdation on Shipboard Fires)

  • 김원욱;김종수;오세진;김성환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.293-294
    • /
    • 2006
  • This paper aims to simulate by FDS(Fire Dynamics Simulator) the distributions of temperature and smoke on fires in accommodations on boards. The paper focuses on analysis of temperature at fire occurrence and soot density. The purpose of this study is to predict the possibility of safe escape and efficient fire extinguishing method using fire simulation results.

  • PDF

TCP/IP & RS-422 통신을 이용한 실시간 모니터링 시스템개발에 관한 연구 (Research of Real Time Monitoring System Development Using TCP/IP & RS-422 Communication)

  • 이주열;문경록;김재문
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.165-168
    • /
    • 2002
  • This paper has been studied about the real time monitoring system development using TCP/IP ethernet and RS-422 serial communication link in general communication methods that rocket fire control agents could be monitoring about real time Rocket fire event procedures and be managing total rocket fire courses. Also, this paper has been studied the HMI(Human Machine Interface) control program and algorithm that guarantee confidential control for the Fire Display System.

  • PDF

국내 전출력 원전 적용 화재 인간신뢰도분석 절차 개발 (Development of a Fire Human Reliability Analysis Procedure for Full Power Operation of the Korean Nuclear Power Plants)

  • 최선영;강대일
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.87-96
    • /
    • 2020
  • The purpose of this paper is to develop a fire HRA (Human Reliability Analysis) procedure for full power operation of domestic NPPs (Nuclear Power Plants). For the development of fire HRA procedure, the recent research results of NUREG-1921 in an effort to meet the requirements of the ASME/ANS PRA Standard were reviewed. The K-HRA method, a standard method for HRA of a domestic level 1 PSA (Probabilistic Safety Assessment) and fire related procedures in domestic NPPs were reviewed. Based on the review, a procedure for the fire HRA required for a domestic fire PSA based on the K-HRA method was developed. To this end, HRA issues such as new operator actions required in the event of a fire and complexity of fire situations were considered. Based on the four kinds of HFE (Human Failure Event) developed for a fire HRA in this research, a qualitative analysis such as feasibility evaluation was suggested. And also a quantitative analysis process which consists of screening analysis and detailed analysis was proposed. For the qualitative analysis, a screening analysis by NUREG-1921 was used. In this research, the screening criteria for the screening analysis was modified to reduce vague description and to reflect recent experimental results. For a detailed analysis, the K-HRA method and scoping analysis by NUREG-1921 were adopted. To apply K-HRA to fire HRA for quantification, efforts to modify PSFs (Performance Shaping Factors) of K-HRA to reflect fire situation and effects were made. For example, an absence of STA (Shift Technical Advisor) to command a fire brigade at a fire area is considered and the absence time should be reflected for a HEP (Human Error Probability) quantification. Based on the fire HRA procedure developed in this paper, a case study for HEP quantification such as a screening analysis and detailed analysis with the modified K-HRA was performed. It is expected that the HRA procedure suggested in this paper will be utilized for fire PSA for domestic NPPs as it is the first attempt to establish an HRA process considering fire effects.

실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구 (Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors)

  • 최수길;진세영;박상민;남영재;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.37-46
    • /
    • 2020
  • 본 논문은 실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구이다. 공기질 측정인자들의 화재감지 경향성을 측정하기 위해 연기감지기 감도시험기를 이용한 작동실험과 UL 268에서 규정하고 있는 종이화재실험을 진행하였다. 연기감지기 감도시험기를 이용한 작동실험 및 UL 268 종이화재실험에 측정된 각각의 측정값을 교차 대입한 결과 공기질 측정기(IAQ) S1의 경우 PM 10(평균값제외), HCHO(평균값 및 최대값 제외), IAQ S2의 경우 PM 1.0, PM 2.5, PM 10, 연소가스분석기(CGA)의 경우 CO(평균값 및 최대값 제외)가 모든 실험 조건에서 연기발생에 따른 측정값의 변화를 통해 경향성을 관찰할 수 있었다. 특히, 본 실험 조건에서 측정되는 인자들 중 적응성이 가장 우수한 PM 10 및 CO는 화재감지 인자로 활용 가능할 것으로 생각된다.

열.전류 감지기를 이용한 전기화재감지시스템 (Electrical Fire Detection System using Temperature and Current Detectors)

  • 김두현;김성철
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents the development of an electrical fire detection system using digital temperature and current detectors in order to sound for electrical fire in advance. As the demand for electricity is increasing and industrial facilities are getting more complex and larger in size, the losses of human life and property are on the increase by electrical fires. In order to prevent electrical fires, it is required to find out fire signatures, or electric signal of the overcurrent and overheating. Therefore, in this paper, developed is an electrical fire detection system based on the detection of signal for overcurrent and overheating to prevent electrical accidents in advance that happen in electrical wires. The developed system gives an alarm by computer monitor, speaker system and mobile phone before electrical fires occur and give severe damages to human beings and properties, and the system can be implemented and supplied for business and residental buildings at a low price. The usefulness and validity of the system, also, verified in this paper by case study and experiments.

CCD 카메라를 이용한 화재감지 및 화재 위치 추적 (Fire Sensing and Position Tracing using CCD Camera)

  • 김장원;백동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.166-168
    • /
    • 2009
  • In this paper, we studied fire sensing and position tracing system in fire region. The coordinates of fire position is communicated to fire suppression system immediately. And the fire is suppressed by this system effectively. For the purpose, the fire occurrence region images are extracted with two different CCD surveillance cameras and fire occurrence are sensed, I suggested a method to measure the fire occurrence position. It was able to be sensed early experiment result fire outbreak and, I was able to understand a fire outbreak position coordinate at the moment when a fire occurred and, I confirmed that I could accomplish warning official announcement and fire suppression in an auto.

  • PDF

다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발 (Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors)

  • 이광재;이연성
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

A Case Study on the Fire of Factory Buildings in Korea

  • Jee, Nam-Yong;Lee, Kyung-Ku;Suh, Chee-Ho
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.450-455
    • /
    • 1997
  • According to the fire statistics of the Ministry of Home Affairs, the fire ratio in factories, work places and warehouses shows 21.5% among total fire of buildings except the fire on cars or other fires. Especially, the buildings like factories and warehouses, which have a lot of ignitable sources and thus always have a strong possibility of fire, are needed to have well planned strategy in terms of life safety and property protection. In this respect, the present paper analyses the existing fire cases in factories, finds out the fire properties of factory buildings, and evaluates the codes concerning fire resistance and fire severity.

  • PDF

전기안전 업무의 비용효과 분석을 위한 전기화재 손실비용 추정방법 개발 (The Development on the Estimate method for the Cost-Effect Analysis of the Electrical Safety Management)

  • 유재근
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.349-352
    • /
    • 2015
  • This paper estimates electrical fire damage cost-effect to analyze electrical safety efficiency by applying a cost-benefit analysis method for analyzing the efficiency of a business public interest. Electrical fire loss statistics data was presented as direct costs and casualties, including deaths due to an electrical fire, this paper adds overhead "Incidental Cost of Accidents to the Employer" by W. H. Heinrich was applied to estimate the cost of economic loss. Also wounded, including the loss of human deaths by referring to the car accident insurance claims costs and human development estimated the losses caused by an electrical fire. And to perform a cost-benefit analysis of the electrical safety as a result of future work. In this paper, the economic effect of the electric field of safety and public interest work to systematically presented.

The Design and Implementation of Mobile Application Solution for Forest Fire based on Drone Photography and Amazon Web Service (AWS)

  • Choi, Si-eun;Bang, Jong-ho
    • 인터넷정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.31-37
    • /
    • 2020
  • Last year's Goseong-Sokcho forest fires have highlighted the limitations of extinguishing work for night-time forest fire and the importance of quick identification for information on the spread of forest fire. However, it is not easy to find services that take into account the characteristics of forest fires, as most existing disaster-related mobile applications and research assume various disaster situations rather than just forest fire situations. Therefore, a system that can provide information quickly is needed, taking into account the characteristics of forest fires and the limitations of extinguishing work. In this paper, we propose evacuation route guidance services that bypass areas where fire has already spread, supplement existing methods of extinguishing work, and provide general information on forest fire situations in real time, by putting drones into forest fire situations. It has been implemented to automate image analysis using the Rekognition service of Amazon Web Service (AWS), and the results of fire detection and the T Map API guide the evacuation path. It is expected that the results of this paper will allow efficient and rapid rescue and extinguishing work to be carried out, and further reduce the damage of human life caused by forest fires.