• Title/Summary/Keyword: paper break

Search Result 783, Processing Time 0.027 seconds

Modelling of RV Ledge Region for Dynamic Analysis of Coupled Reactor Vessel Internals and Core

  • Jhung, Myung J.
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.164-172
    • /
    • 1998
  • This paper presents the detailed modelling of reactor vessel ledge region for the dynamic analysis of the coupled internals and core model. The dynamic responses due to earthquake and pipe break are calculated using the input motions of reactor vessel taken from Ulchin nuclear power plant units 3 and 4. Two different representations for detailed and simplified models of the RV ledge region are made. The dynamic responses of the reactor internals components are compared between them. Response characteristics are reported and simplified model is suggested for earthquake and pipe break analysis for the future design of the reactor internals.

  • PDF

A Study on Development of EMC Filter for Power Lime in Break-box (인입선 Break-box 내의 EMC 대책용 필터 개발에 관한 연구)

  • 배대환;김동일;배재영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.245-250
    • /
    • 2001
  • Since the most of malfunctions in the industrial equipment controlled by processors is occurred by the Electrical Fast Transient(EFT), the International Electrotechnical Commission(IEC) prepared the dummy signal to test the immunity level of the equipments. In this paper, we designed a new EMC fitter for power line in break-box, which consist of the feed-through capacitor and ferrite materials with high permeability, which was wound or inserted, in the second layer of the power cable in order to increase common mode inductance. We have obtained a excellent insertion loss characteristics over wide frequency band from 10 MHz up to 1.5 GHz. It is expected that the new EMC filter could be effectively used for industrial, MIL, and medical equipments to reduce a malfunctions and be suitable for IEC 61000-4-4.

  • PDF

Dynamic load concentration caused by a break in a Lamina with viscoelastic matrix

  • Reza, Arash;Sedighi, Hamid M.;Soleimani, Mahdi
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1465-1478
    • /
    • 2015
  • The effect of cutting off fibers on transient load in a polymeric matrix composite lamina was studied in this paper. The behavior of fibers was considered to be linear elastic and the matrix behavior was considered to be linear viscoelastic. To model the viscoelastic behavior of matrix, a three parameter solid model was employed. To conduct this research, finite difference method was used. The governing equations were obtained using Shear-lag theory and were solved using boundary and initial conditions before and after the development of break. Using finite difference method, the governing integro-differential equations were developed and normal stress in the fibers is obtained. Particular attention is paid the dynamic overshoot resulting when the fibers are suddenly broken. Results show that considering viscoelastic properties of matrix causes a decrease in dynamic load concentration factor and an increase in static load concentration factor. Also with increases the number of broken fibers, trend of increasing load concentration factor decreases gradually. Furthermore, the overshoot of load in fibers adjacent to the break in a polymeric matrix with high transient time is lower than a matrix with lower transient time, but the load concentration factor in the matrix with high transient time is lower.

A Study on Application of Learning Loss at Labor Cost Calculation in Case of Production Break Occurrence (방산원가 노무비 산정시 생산중단에 의한 학습손실 적용방안 연구)

  • Moon, Keong-Min;Lee, Yong-Bok;Kang, Sung-Jin
    • Journal of the military operations research society of Korea
    • /
    • v.36 no.2
    • /
    • pp.1-10
    • /
    • 2010
  • Learning rate is generally applied to estimate an appropriate production labor cost. Learning effect is obtained from repetitive work during the production period under 3 assumptions ; homogeneous production, same producer, quantity measure in continuous unit. However, production breaks occur frequently in Korean defense industry environment because of budget constraint and annual requirements. In this case previous learning effect can not be applied due to learning loss. This paper proposed the application of learning rate when a production break occurs in Korea defense industry. To obtain a learning loss, we surveyed various learning loss factors for different production breaks(6, 12, 18 months) from 4 defense industry companies. Then, we estimate the first unit labor hours in re-production phase after production break using Anderlohr method and Retrograde method with the result of the survey. This work is the first attempt to show a method which defines and evaluates the learning loss factors in Korean defense industry environment.

Condition Monitoring for Coil Break Using Features of Stationary Rolling Region (정상 압연 구간의 특징을 이용한 판 파단의 상태감시)

  • Oh, J.S.;Yang, S.W.;Shim, M.C.;Caesarendra, W.;Yang, B.S.;Lee, W.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1252-1259
    • /
    • 2009
  • Due to the international competition and global pressure, the roll speed is increased. However, higher speeds increase the power density in the process as well as the plant's potential to react with vibrations. Under certain operating conditions, vibrations may occur, which again cause chattermarks, strip rupture or coil break fault. The appropriate condition monitoring is needed to improve product quality and availability. The aim of condition monitoring is to reduce maintenance costs, increase productivity and improve product quality. This paper proposes a condition monitoring tool designed for the classification of coil break fault. This method is used to cold rolling mill for faults monitoring based on vibration and motor current signals. The results show that the performance of classification has high accuracy based on experimental work.

Cavitation Effects on Radiated Sounds and Break Efficiency Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (ESWL 장치에 의한 방사음 및 파쇄효율에 미치는 캐비테이션의 영향)

  • 장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.205-210
    • /
    • 2001
  • The effectiveness of extracorporeal shock wave lithotripter for the therapy of calculus has been well known in the field of urology. There are many studies about the performance of that and the influence into human body. Among them, it is an impertant issue that cavitation is always deal with shock wave. A medium of the shock wave is related to the cavitation phenomenon. In this paper, therefore, we analysis the spectra of radiated sounds and the break efficiency on focal region due to the medium of shock wave. The results show that the cavitation bubbles produce a harmful on the break efficiency and the stability of the radiated sounds due to the ESWL.

  • PDF

The Relativity between Vibration of Phantom and Its Break Efficiency Due to Position of Focus Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 충격파 체외 쇄석기 사용시 초점위치에 의한 대상물의 진동과 파쇄효율과의 상관성)

  • 장윤석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.35-40
    • /
    • 2000
  • In this paper, the relation between the radiated sound and the vibration due to piezoelectric ESWL(Extracorporeal Shock Wave Lithotripter) is examined and the results of the experiments are represented. Next, the relation between the focal point and the vibration of the objects is examined. The same experiments with the objects that can be broken are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

Structural safety reliability of concrete buildings of HTR-PM in accidental double-ended break of hot gas ducts

  • Guo, Quanquan;Wang, Shaoxu;Chen, Shenggang;Sun, Yunlong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1051-1065
    • /
    • 2020
  • Safety analysis of nuclear power plant (NPP) especially in accident conditions is a basic and necessary issue for applications and commercialization of reactors. Many previous researches and development works have been conducted. However, most achievements focused on the safety reliability of primary pressure system vessels. Few literatures studied the structural safety of huge concrete structures surrounding primary pressure system, especially for the fourth generation NPP which allows existing of through cracks. In this paper, structural safety reliability of concrete structures of HTR-PM in accidental double-ended break of hot gas ducts was studied by Exceedance Probability Method. It was calculated by Monte Carlo approaches applying numerical simulations by Abaqus. Damage parameters were proposed and used to define the property of concrete, which can perfectly describe the crack state of concrete structures. Calculation results indicated that functional failure determined by deterministic safety analysis was decided by the crack resistance capability of containment buildings, whereas the bearing capacity of concrete structures possess a high safety margin. The failure probability of concrete structures during an accident of double-ended break of hot gas ducts will be 31.18%. Adding the consideration the contingency occurrence probability of the accident, probability of functional failure is sufficiently low.

Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker (2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구)

  • Oh, SeungRyle;Han, Kisun;Kim, TaeKyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Recently, the circuit-breaker rated voltage is getting higher as the transmission voltage increases. To increase the circuit-breaker rated voltage, a multi-break circuit-breaker which has two or more breakers in series is adopted. For multi-break circuit-breaker, a grading capacitor is used to mitigate the Transient Recovery Voltage(TRV) and control the voltage distribution across the individual interrupter units. However, all over the world, there are many failures such as mechanical damage, explosion due to insulation breakdown. Therefore, it is necessary to study the causes of failure and the new performance verification method. In this paper, we investigate the causes of dielectric breakdown of the grading capacitors in the KEPCO power system and propose the performance verification method.