• Title/Summary/Keyword: paper break

Search Result 786, Processing Time 0.031 seconds

A Study of Measuring Existing Steel Stress Using Magnetoelasticity (자기유도 현상을 이용한 철근의 잔존응력 측정기술 연구)

  • Rhim Hong-Chul;Cho Young-Sik
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.185-187
    • /
    • 2006
  • This study deals with characterization and the application of magnetoelasticity as a device which measures existing steel stress. Available method of measuring existing stress needs break the concrete and cut the steel bar. But Proposed method doesn't need to cut the steel bar. A successful application of magnetoelasticity depends on the linearity of the relationship between the elastic and magnetic response due to loading. To investigate the correlation between two, steel bars are loaded in tension under uniaxial loading while the magnetic reading is recorded. Results showed linearity or partial-linearity of the elastic behavior of steel bars in relation to magnetic change. In the paper, the various factors affecting the measurements are also discussed.

  • PDF

The Characteristic Study for Small Current Breaking of High Speed DC Circuit Breaker (직류고속도차단기의 소전류 차단 특성연구)

  • Min Byung-Hoon;Jang Woo-Jin;Ko In-Suk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.396-402
    • /
    • 2006
  • Even the case DC circuit Breaker have good quality for interruption of high current like heavy load current, short-circuit current, the verification for small current breaking capability of circuit breaker should be performed. It comes from the reason DC small current breaking failure can be lead to break out second heavy fault condition and in the long run substation shutdown. In this paper, we can find the characteristics of DC small current and international test standard discription about small current breaking and one of the proper solution to get over it.

Piecewise Regression Model for Solenoid Embedded Inductors Based on the Quasi-newton Method

  • Ko, Young-Don;Kim, Kil-Han;Yun, Il-Gu;Lee, Kyu-Bok;Kim, Jong-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.256-261
    • /
    • 2005
  • This paper presents that the modeling to predict the characteristics with respect to the performance of solenoid embedded inductors manufactured by LTCC process via the nonlinear regression model based on the quasi-Newton method. In order to reduce the runs, the design of experiments (DOE) was used to generate the design space. The nonlinear process models were constructed by the piecewise regression model based on the quasi-Newton method for estimating the model coefficient with the break point on the statistical confidence intervals. Those models were verified by the model accuracy checking based on the assumption statistically.

A Comparison of LSPM Synchronous Motor and Induction Motor (LSPM 동기전동기와 유도전동기의 특성 비교)

  • Kim, Byong-Kuk;Jo, Won-Yung;Lee, In-Jae;Moon, Ji-Woo;Kim, Mi-Jung;Lim, Seong-Hwan;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.829-830
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

Design of Snubber for the AVR to supply Excitor (여자기 공급용 AVR의 Snubber 설계)

  • Oh, Sang-Rok;Lee, Cheol-Seung;Ryu, Ho-Sun;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.313-315
    • /
    • 1994
  • In this paper, it is consider spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

Preliminary Structural Segmentation of the Yangsan Fault (양산단층의 구조적 분절화 기초연구)

  • 장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.49-56
    • /
    • 1997
  • Most large strike-slip faults do not rupture their entire length during single faulting but generally break in segments which are different in location and time of faulting. Studies related to the development of the Yangsan fault have been reported based on partial results from characteristics of geolgocial distribution, geophysical prospecting and paleostress analyses. This paper shows, based on preliminary results, that the Yangsan fault could be divided into four structural areas along entire length. These areas are different in geological distribution, bedding attitude measured from sedimentary rocks, strike of main fault, geometry of small faults, termination types of fault tips, cyclic variation of fault zone width, and arrangement of paleostress. Therefore, the Yangsan fault could be divided into at least four segments.

  • PDF

A Study on the High Speed Breaking of Parallel Arcing (병렬아크의 고속 차단에 관한 연구)

  • Kim, Il-Kwon;Ji, Hong-Keun;Kim, Sung-Uk;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.327-331
    • /
    • 2008
  • This paper dealt with high speed breaking method to parallel arcing in low-voltage systems. The proposed high speed breaking circuit consists of a Rogowski coil and an integrator, and operates with an earth leakage circuit breaker (ELCB). A parallel arcing state was simulated by a short circuit using stripped wires. In this test, we analyzed tripping characteristics of the circuit breaker by the length of wires from 5m to 30m. From the experimental results, we confirmed that the proposed method can break the parallel arcing within a few millisecond.

  • PDF

Development of Automatic Node Generation Algorithm and Preprocessing Technique for $\rho$-Version Finite Element Program ($\rho$-Version 유한요소 프로그램을 위한 자동절점생성 알고리즘 및 전처리 기법 개발)

  • 조준형;홍종현;우광성
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.69-76
    • /
    • 1998
  • Due to the drastic improvement of computer hardware and operating system, it is easy to break through the main defects of limited computer memory and processing time, etc. To keep up with this situation, this paper is focused on developing the preprocessor program with the input method based on vector graphic editor and the preprocessing technique including automatic node generation algorithm for the $\rho$-version finite element program. To develop this preprocessor program, the special data structure and the OOP(Object Oriented Programming) have been used by the Visual Basic 4.0. The Special data structure is proposed to describe the geometric data of node numberings and coordinates suitable for the $\rho$-version finite element program, which are quite different from the comvential h-version finite element program.

  • PDF

A Study on the real-time Position-searching System using the Amplitude Approach Method (Amplitude Approach 방법을 이용한 신호원의 실시간 위치탐지에 관한 연구)

  • 신정록;송우영
    • Journal of the Korea Society of Computer and Information
    • /
    • v.5 no.2
    • /
    • pp.105-114
    • /
    • 2000
  • In this Paper in order to break with real-time position of signal source which have first dimension motion, the N antenna is arrayed with half-circle, the incident angle of signal source from receiving power pattern to receive at receive antenna is estimated and measured, and the system that measure horizontal moving distance of signal source is designed. Signal source is constructed by 10-20dBm transmitter power which frequency is 10.52GHz of X band, and on horizontally moving the position of signal source. validity of new method is confirmed.

  • PDF

Advanced Composite Material Slabs for Tall Buildings (고층 건물 경량화를 위한 첨단 복합재료 상판)

  • 김덕현;심도식;김성환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.10a
    • /
    • pp.126-133
    • /
    • 1997
  • For each construction material used, there is certain theoretical limit in sizes. For tall building construction, the reduction in slab weight is the first step to take in order to break such size limits. In this paper, the feasibility of such objective is proven and given by numerical analysis result. For a typical building slab, both concrete and advanced composite sandwich panels are considered. The concrete slab is treated as a special orthotropic plate to obtain more accurate result. For each panel, the deflection under the dead and live loads is compared, since both tensile and compressive strengths of the composites are far more higher than those of concrete. All types of sandwich panels considered, except one case, have weights less than one tenth of that of reinforced concrete slab, with deflections less than that of the concrete slab. The cost analysis result and manufacturing methods will be reported later.