• 제목/요약/키워드: panel heating

검색결과 185건 처리시간 0.025초

에어캡 적층을 통한 에어캡 벽 모듈 개발 (Development of Aircap Wall Module through the Lamination of Aircap)

  • 김경수;서장후;김용성;이행우
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.504-514
    • /
    • 2017
  • The insulation performance of aircaps has been recognized and various studies regarding the aircap as a solution to increased building energy consumption are being carried out. However, the aircap is not durable and therefore it cannot play the role of an independent finishing material. Accordingly, the purpose of this study is to suggest an aircap wall module with improved durability through the lamination of the aircap and verify its effectiveness by evaluating its energy saving performance for lighting and air conditioning through a full-scale testbed. The conclusions of this study are as follows. 1) The aircap wall module featuring a laminated aircap that is being proposed in this study can save lighting energy due to the permeability of the aircap in comparison to previous insulating materials. 2) The aircap wall module with a laminated aircap is effective in improving heating and air-conditioning energy saving when it is more than 15 cm-thick during summer and winter in comparison to a 5 cm-thick prefabricated panel. 3) The aircap wall module featuring a laminated aircap is effective in improving lighting and heating and air-conditioning energy saving when it is 10 cm- and 5 cm-thick during summer and winter, respectively, in comparison to a 5 cm-thick prefabricated panel.

기판 소재에 따른 패널 레벨 패키지 공정 단계별 warpage 해석 (Process Induced Warpage Simulation for Panel Level Package)

  • 문아영;김성동
    • 마이크로전자및패키징학회지
    • /
    • 제25권4호
    • /
    • pp.41-45
    • /
    • 2018
  • 패널 레벨 패키지(Panel Level Package)에서 공정 단계별로 발생하는 휨(warpage)에 대해 유한요소법을 이용하여 전산모사를 진행하였다. $5{\times}5mm^2$ 크기의 실리콘 칩이 총 221개가 포함된 $122.4{\times}93.6mm^2$ 크기의 패널에 대해서 (1) EMC 몰딩, (2) detach core 부착, (3) 가열, (4) 캐리어 분리, (5) 냉각의 5 단계에 대해서 해석을 수행하였으며, 캐리어와 detach core 소재로 유리와 FR4의 조합이 휨 현상에 미치는 영향을 조사하였다. 캐리어 및 detach core의 소재에 따라 공정 단계별로 휨의 경향이 다르게 나타나고 있으나, 최종적으로는 유리를 캐리어로 사용하는 경우에 detach core의 소재와 관계없이 FR4 캐리어에 비해 낮은 휨 값을 나타내었으며 유리 캐리어와 유리 detach core의 조합에서 가장 낮은 휨 값이 관찰되었다.

고설 딸기 관부 난방시스템의 에너지 절감 효과 (Energy Saving Effect for High Bed Strawberry Using a Crown Heating System)

  • 문종필;박석호;권진경;강연구;이재한;김형권
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.420-428
    • /
    • 2019
  • 본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관(백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 $20{\sim}23^{\circ}C$, 관부 온도를 $13{\sim}15^{\circ}C$로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 $20{\sim}23^{\circ}C$의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 $4^{\circ}C$ + 관부난방(처리 1), 공간 난방 $8^{\circ}C$ (대조구), 공간 난방 $6^{\circ}C$ + 관부난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 $8^{\circ}C$(대조구)의 경우 1,320L(100%), 공간난방 $4^{\circ}C$ + 관부난방의 경우 928L(70.3%), 공간난방 $6^{\circ}C$ + 관부난방의 경우 1,161L (88%)로 계측되었다. 공간난방 $4^{\circ}C$ + 관부난방(처리 1) 및 공간난방 $6^{\circ}C$ + 관부난방(처리 2)은 $8^{\circ}C$ 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.

큰 느타리버섯 재배사의 환경설계용 자료 분석 (Analysis of Environmental Design Data for Growing Pleurotus ervngii)

  • 윤용철;서원명;이인복
    • 생물환경조절학회지
    • /
    • 제14권2호
    • /
    • pp.95-105
    • /
    • 2005
  • 본 연구에서는 큰 느타리버섯 재배사의 에너지 이용효율과 소요에너지 산정에 대한 기초 자료를 얻기 위하여 기존에 제시한 재배사모형(영구형 단동 및 연동과 반영구형 단동)들을 대상으로 열수지 시뮬레이션을 실시하였다. 또한 재배사의 단열재 및 피복재의 열전달 저항치를 산정한 후, 재배사의 냉$\cdot$난방 부하량을 추정하였다. 진주지방의 경우, 큰 느타리버섯 재배사의 냉$\cdot$난방 D-H 증감현상은 실내 설정온도의 변화에 따라 거의 직선적인 변화를 보였으며, 변화의 정도는 냉방 D-U가 난방 D-H에 비해 훨씬 예민하다는 것을 알 수 있었다. 따라서 설정온도는 물론 실내 유지온도의 제어 양상에 따라 소요 에너지의 변화를 예측할 수 있을 뿐만 아니라, 앞으로 개발될 버섯 재배사의 환경모형 시뮬레이션 검정과 에너지 소요량 추정에도 산정 된 D-H가 유익하게 활용될 수 있을 것으로 판단되었다. 그리고 동일한 재배공간 확보를 전제로 할 경우, 다중 피복의 반영구형 재배사에 비해 다양한 두께 및 재질로 생산되고 있는 영구형 재배사가 단열성능 면에서 현저히 유리하였다 단동 대비 연동구조의 에너지 효율, 단열 정도에 따른 에너지 소요량의 변화를 쉽게 가늠할 수 있을 뿐만 아니라 주어진 지역과 주요 표면의 단열 정도와 표면상태 등에 따라 계절별 또는 재배 주기별 소요 에너지를 예측함으로서 재배사의 구조 및 환경적 최적화를 꾀할 수 있을 것으로 판단되었다.

거대 화상용 PIV 시스템을 이용한 실차 내부 공기벨트 토출흐름의 속도장 측정 연구 (PIV Measurements of Ventilation Flow from the Air Vent of a Real Passenger Car)

  • 이진평;김학림;이상준
    • 한국가시화정보학회지
    • /
    • 제7권1호
    • /
    • pp.3-8
    • /
    • 2009
  • Most vehicles have a heating, ventilating and air conditioning (HVAC) device to control the thermal condition and to make comfortable environment in the passenger compartment. The improvement of ventilation flow inside the passenger compartment is crucial for providing comfortable environment. For this, better understanding on the variation of flow characteristics of ventilation air inside the passenger compartment with respect to various ventilation modes is strongly required. Most previous studies on the ventilation flow in a car cabin were carried out using computational fluid dynamics (CFD) analysis or scale-down water-model experiments. In this study, whole ventilation flow discharged from the air vent of a real passenger car was measured using a special PIV (particle image velocimetry) system for large-size FOV (field of view). Under real recirculation ventilation condition, the spatial distributions of stream-wise turbulence intensity and mean velocity were measured in the vortical panel-duct center plane under the panel ventilation mode. These experimental data would be useful for understanding the detailed flow structure of real ventilation flow and validating numerical predictions.

창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구 (Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM))

  • 송영학;김기태;구보경;이건호
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

국부 경화 열처리된 차체 부품의 기계적 성질과 미세조직에 관한 연구 (A Study on Mechanical Properties and Microstructure of Local-Hardening Heat-Treated Automotive Panel)

  • 이재호;정우창
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.301-308
    • /
    • 2010
  • A steel with chemical composition, 0.22% C, 0.25% Si, 1.26% Mn, 0.22% Cr, 0.04% Ti, 0.0042% B, and a microstructure of ferrite and spheroidized cementite has been press-formed to automotive center pillar followed by local-hardening heat-treatment. Hardness, tensile properties, fractography, microstructure and surface roughness of local-hardening heat-treated automotive center pillar have been examined. The directly heated and quenched area had fully martensitic structure with Vickers hardenss in the range of 500 to 510. The heat affected area close to the directly heated area showed dual-phase structure of ferrite and martensite. The width of the heat-treated and heat-affected areas after the local-hardening heat treatment was ranging from 32 mm to 50 mm. The surface of the local-hardening heat-treated center pillar revealed some temper color as a consequence of the oxidation during the heat treatment, but the surface roughness was not affected by the local-hardening heat treatment.

Termosyphon의 지열채열 성능에 관한 고찰 (A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon)

  • 신현준;서정윤
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발 (A Development of Counter Flow Type of Cooling System for Effective Panel Cooling)

  • 이중순
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.802-807
    • /
    • 2010
  • 산업용 컴퓨터를 포한한 다양한 형태의 공작기계나 자동화 시스템의 배전반이나 제어 패널을 고효율적으로 냉각시킬 수 있는 시스템은 매우 중요한 요소이다. 따라서 이러한 냉각장치는 산업용 로봇, 수치제어 공작기계 등과 같은, 다양한 산업용 시스템에 널리 사용되고 있다. 본 연구에서는 패널 내부를 순환하는 공기를 강제적으로 유동시키는 냉각방식을 채택하여 효과적인 패널 냉각을 위한 대향류형 냉각장치를 개발하였다. 본 연구를 통하여 효과적인 냉각장치를 위한 핀 어셈블리를 개발하여 제어용 패널에 적용한 결과, 기존의 시스템에 비하여 냉각 성능과 열교환율이 개선된 결과를 확인할 수 있었다. 연구에 적용된 상용의 시스템에 비해 공기의 유동량은 약 20% 정도 증가하는 현상을 보였고, 열교환량은 약 2배 이상 증가하는 현상을 확인할 수 있었다.

도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구 (A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire)

  • 박경훈;김흥열;유용호;이철호;김형준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF