• Title/Summary/Keyword: panel evaluation

Search Result 762, Processing Time 0.024 seconds

Implementation of Smart Automatic Warehouse to Improve Space Utilization

  • Hwa-La Hur;Yeon-Ho Kuk;Myeong-Chul Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.10
    • /
    • pp.171-178
    • /
    • 2023
  • In this paper, we propose a smart automated warehouse to maximize space utilization. Previous elevator-type automatic warehouses were designed with a maximum payload of 100kg on trays, which has the problem of extremely limiting the number of pallets that can be loaded within the space. In this paper, we design a smart warehouse that can maximize space utilization with a maximum vertical stiffness of 300kg. As a result of the performance evaluation of the implemented warehouse, the maximum payload was 500.6kg, which satisfied the original design and requirements, the lifting speed was 0.5m/s, the operating noise of the device was 67.1dB, the receiving and forwarding time of the pallet was 36.92sec, the deflection amount was 4mm, and excellent performance was confirmed in all evaluation items. In addition, the PLC control method, which designs the control UI and control panel separately, was integrated into the PC system to improve interoperability and maintainability with various process management systems. In the future, we plan to develop it into a fully automatic smart warehouse by linking IoT sensor-based logistics robots.

A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire (도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Yoo, Yong-Ho;Lee, Chul-Ho;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

Interference Effects of Change in Wind Passage of a Building Group on Wind Loads and Wind Environments (건축물군의 바람길변화로 인한 풍하중 상호간섭 및 풍환경)

  • Cho, Kang-Pyo;Hong, Sung-Il;Kim, Mu-Hwan;Lee, Ok-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.402-409
    • /
    • 2008
  • Wind loads and environments in realistic situations surrounded by neighboring buildings may be considerably different from those in idealized or simplified situations such as codes and standards. Interference effects of change in wind passage of a building group on wind loads and wind environments are reviewed. Wind-induced interference effects depend mainly on the building geometry and arrangement of these structures, their orientation and upstream terrain conditions. The most important factor among them may be the arrangement of building structures which can change the wind direction directly. Interference effects regarding wind loads are discussed with examples of window damages by typhoon and of pressure measurements in the boundary layer wind tunnel. Wind environment problems are also discussed, specially underlined on pedestrian comfort and safety. Various evaluation techniques or standards of wind environment are introduced. The change of wind velocity between the panel-type apartment buildings is examined, depending on the distance each other.

  • PDF

Study on Thermal Conductive PV(PhotoVoltaic) Backsheet using MgO Masterbatch with High Thermal Conductivity (고열전도도 MgO를 이용한 열전도성 PV(PhotoVoltaic) 백시트의 연구)

  • Kim, Chang-Hee;Jang, Hyun-Tae;Park, Jong-Se;Yoon, Jong-Kuk;Noh, Eun-Seob;Park, Ji-Soo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.448-453
    • /
    • 2018
  • PV module protective film plays an important role in protecting the solar cell from external environment by anti-hydrolysis polyester, UV resistance and mechanical properties. The backsheet was manufactured by using Roll-to-Roll dry laminating process. The backsheet structure is composed of 3 layers, which are PE, PET, and Fluorine polymer films. In this study, we have experimented the variation of thermal conductivities depending on MgO inputs 10% to 25% in order to confirm the dependence of the module efficiencies. High thermal conductive backsheet can increase the module output power efficiency because the heat is dissipated by spreading out the internal heat. Long-term environment weatherability tests were conducted for confirming 25 year reliability in the field such as PCT, UV, and power efficiency degradations. As the evaluation result, high thermal conductivity can be effective for increase of power efficiency of solar panel by using thermal conductive MgO masterbatch.

Development of Outcome Indicators of Urinary Incontinence for Quality Evaluation in Long Term Care Hospitals (요양병원의 서비스 질 평가를 위한 요실금 결과 지표 개발)

  • Yoon, Ju-Young;Lee, Ji-Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.1
    • /
    • pp.110-118
    • /
    • 2010
  • Purpose: To develop outcome indicators of urinary incontinence to measure quality of care in long term care hospitals in Korea. Methods: The draft indicators of urinary incontinence were developed from a literature review and clinical expert panel. A survey of medical records of 280 patients in 20 hospitals was conducted to test inter-rater reliability. Statistical analysis was done to test risk adjustment criteria, variation between hospitals, and stability of indicators, using assessment data from 77,918 patients in 623 hospitals. Results: The inter-rater reliability of items was high (Kappa range: 0.66- 0.92). Severe cognitive impairment (odds ratio [OR]: 3.15, confidence interval [CI]: 3.03-3.26) and total mobility activities of daily living (ADLs) dependency (OR: 4.85, CI: 4.72-4.98) increased the prevalence of urinary incontinence, thus they proved to be significant criteria to stratify high and low risk groups. The prevalence for low risk showed more substantial variation than the high risk group. The indicators were stable over one month. Conclusion: This study demonstrated the feasibility of outcome indicators of urinary incontinence. Improving the reliability of the patient assessment tool and refining the indicators through validation study is a must for future study.

A Study on The Development and Evaluation of Mine Detective Gear (지뢰 탐지용 방호복 구성과 방호성능 및 착용감 평가)

  • 손부현;최혜선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.4
    • /
    • pp.707-718
    • /
    • 2001
  • The purpose of this study is to evaluate a newly developed protective suit with the fragments of grenade. The protection efficiency should be strengthened upon the degree of wound. The fragment weight of the used grenade was measured and the kinetic energy of the maximum speed of the fragments in the field test was 137.7J and this could be the protective efficiency test by the multitude fragments in less than 0.031g of the M16A1. The panel inserted to the new demining suit has protection rate of 100% within the distance of 1m and sample II has protection rate of 100% only beyond the distance of 5m. The test showed that the protection rate on the protective suit of the existing garment was comparatively high, however, the protection rate of the sleeve part was very low. The new demining suit through the research demand some complementary measures to lower the temperatures in ear, average skin temperatures, and the temperatures-humidity inside the clothing for summer climate condition, It showed that 30 minutes of rest on the clothing was difficult to go back to the original condition. But in winter climate condition, there was no problem in the temperature, humidity, and comfort to go back to the original condition during the rest and was better in warmth.

  • PDF

The Effects of the Tai Chi Exercise on Metabolic Syndrome and Health-related Quality of Life in Middle-aged Women (타이치 운동이 중년여성의 대사증후군 위험인자 및 건강관련 삶의 질에 미치는 영향)

  • Eom, Ae-Yong
    • Journal of muscle and joint health
    • /
    • v.19 no.2
    • /
    • pp.152-160
    • /
    • 2012
  • Purpose: The purpose of this study was to test the effects of the Tai Chi exercise on metabolic syndrome and health-related quality of life in middle-aged women. Methods: A quasi-experimental design was used. Subjects were sixty middle-aged women with metabolic syndrome. All of the subjects were met the criteria of the National Cholesterol Education Program-Adult Treatment Panel III (NCEP-ATP III). The subjects were divided into the experiment group (n=33) trained the Tai Chi for 12 weeks and the control group (n=27). Metabolic syndrome risk factors including blood pressure, waist circumference, glucose, triglyceride (TG), and high density lipoprotein cholesterol (HDL-C) were measured before and after the 12-week period. Euro Quality of Life Questionnaire 5-Dimensional Classification (EQ-5D) was used to evaluate the health-related quality of life. Results: The experiment group showed significant decreases in diastolic blood pressure, waist circumference, glucose, and TG; and increase in HDL-C compared to the control group. For the health-related quality of life evaluation, the experiment group showed significant improvement more than the control group. Conclusion: The Tai Chi exercise may be effective intervention in preventing cardiovascular disease caused by metabolic syndrome in middle-aged women.

Prediction evaluation of problems happened of Sheet Metal Forming Process Using Shell Element (쉘 요소를 이용한 박판성형공정의 불량 예측 평가)

  • Ko Hyung-Hoon;Lee Chan-Ho;Kang Dong-Kyu;Sul Nam-Ki;Lee Kwang-Sik;Jong Dong-Won
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.481-484
    • /
    • 2005
  • The AutoForm previously used the membrane element and it accomplished sheet metal forming analysis. The membrane analysis has been widely applied to various sheet metal forming processes because of its time effectiveness. However, it's well known that the membrane analysis can not provide correct information for the processes which have considerable bending effects. In this research it tried to compare the analysis results which use the shell element which is applied newly in the AutoForm commercial software with actual experimental results. The shell element is compromise element between continuum element and membrane element. The Finite element method by using shell element is the most efficient numerical method. From this research, it is known that FEA by using shell element can predict accurately the problems happened in actual experimental auto-body panel.

  • PDF

Distributing Board Monitoring System based on Internet of Things (사물인터넷 기반 수배전반 상태 모니터링 시스템)

  • Lee, Young-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.200-206
    • /
    • 2016
  • It is necessary to develop a real-time monitoring system for electric facilities, operating and managing system for the accident prevention of electrical demand facilities anytime, anywhere. In this paper, we propose the implementation of distributing board monitoring system based on Internet of Things(IoT). The proposed system is installed in existing distributing board that it can transmit status information of distributing board and control information through the cloud server and the wireless local area network. The distributing board monitoring system can monitor and control the condition of distributing board by system administrator. The results show that the margin of error was ${\pm}5%$ in performance evaluation.

Optimizing Recipes of Korean-style Cut Noodles with Anchovy Engraulis japonicus Soup Base Residue Powder (멸치(Engraulis japonicus) 잔사 분말을 첨가한 칼국수의 최적화)

  • Lee, So-Yeon;Ryu, Hong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.5
    • /
    • pp.545-555
    • /
    • 2014
  • To develop Korean-style cut noodles with enhanced protein and calcium levels, we manipulated the ratio of dried anchovy Engraulis japonicus soup base residue powder to wheat flour, using a response surface methodology based on trained panel trials to determine the optimum ratio. Texture analysis and nutritional evaluation were also performed on cut noodles containing dried anchovy soup base residue (CNAR). Higher umami taste and springiness, and lower fishy flavor were strongly correlated with overall acceptability. The optimal CNAR formulation consisted of wheat flour (96.02 g), anchovy residue powder (2.67 g), and water (50.64 mL). CNAR had lower gumminess and adhesiveness (P<0.001), but higher springiness, cohesiveness (P<0.001), and chewiness (P<0.05), than the control (original wheat flour cut noodles). The addition of anchovy soup base residue elevated protein, lipid, and ash levels relative to the control. Color values decreased with increasing residue powder content. In vitro protein and starch digestibility of CNAR were lower than in the control (P<0.001). CNAR yielded significantly higher total free amino acid content than the control (P<0.01), leading to CNAR's improved palatability. Dried anchovy soup base residue can be used in wheat flour cut noodles to improve nutrition, sensory acceptability, and profitability.