• Title/Summary/Keyword: paddle

Search Result 167, Processing Time 0.027 seconds

Analysis of Residual Stresses at Manufacturing Precesses for Microaccelerometer Sensors (미소가속도계 센서의 제조공정에서 잔류응력 해석)

  • 김옥삼
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.631-635
    • /
    • 2001
  • The major problems associated with the manufacturing processes of the microaccelerometer based on the tunneling current concept is the residual stress. This paper deals with finite element analysis of residual stress causing pop up phenomenon which are induced in micromachining processes for a microaccelerometers sensor using silicon on insulator(SOI) wafer. After heating the tunnel gap up to $100^{\circ}C$and get it through cooling process and the additional beam up to $80^{\circ}C$get it through the cooling process. We learn the residual stress of each shape and compare the results with each other, after heating the tunnel gap up to $400^{\circ}Cduring$ the Pt deposition process. The equivalent stresses produced during the heating process of focused ion beam(FIB) cut was also to be about $0.02~0.25Pa/^{\circ}C$and cooling process the gradient of residual stresses of about $8.4\{times}10^2Pa/{\mu}m$ still at cantilever beam and connected part of paddle. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer sensors.

  • PDF

Manufacturing Process and Technology of Korean Costumes Made of Fur and Loather (우리나라 모피와 피혁 복식의 제작과정과 기술)

  • An, Bo-Yeon;Hong, Na-Young
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.8
    • /
    • pp.63-73
    • /
    • 2008
  • From the ancient Korea to the late Joseon Korean fur and leather had been preferred in and out of Korea for their good quality and excellent manufacturing skill. Since Unified Silla (A.D.676${\sim}$A.D.936) Korean fur and leather were manufactured divisionally by workmen specialized in materials and products, and such manufacturing process was succeeded to Goryeo and Joseon. Manufacturing of fur and leather was consisted of as follows: hunting and butchering - peeling - beating with a paddle and removing fat - oil manufacturing - drying - tanning, then cutting and sewing, and there was a special caring method. In order to make good fur and leather, each process of manufacturing needed particular techniques and all available methods were tried to have tender fur and leather by using smoking, excrement, lime, vegetable tannin and even cerebral liquid. And also required mouth-chewing and hand-pounding with a lot of time and of labor Keeping furs resilience and flexibility, sowing several skins together, even when the after-all-process skin was converted into clothes, was much more difficult than sewing fabric. Thus, the manufacturing cost was as much expensive as skin materials, and the volume of manufacturing of fur and leather was also limited. Therefore, fur and leather must have been popular for scarcity value in the manufacturing process, and this scarcity must have caused an extreme luxury of fur.

Fabrication of Nb SQUID on an Ultra-sensitive Cantilever (Nb SQUID가 탑재된 초고감도 캔티레버 제작)

  • Kim, Yun-Won;Lee, Soon-Gul;Choi, Jae-Hyuk
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.36-41
    • /
    • 2009
  • Superconducting quantum phenomena are getting attention from the field of metrology area. Following its first successful application of Josephson effect to voltage standard, piconewton force standard was suggested as a candidate for the next application of superconducting quantum effects in metrology. It is predicted that a micron-sized superconducting Nb ring in a strong magnetic field gradient generates a quantized force of the order of sub-piconewtons. In this work, we studied the design and fabrication of Nb superconducting quantum interference device (SQUID) on an ultra-thin silicon cantilever. The Nb SQUID and electrodes were structured on a silicon-on-insulator (SOI) wafer by dc magnetron sputtering and lift-off lithography. Using the resulting SOI wafer, we fabricated V-shaped and parallel-beam cantilevers, each with a $30-{\mu}m$-wide paddle; the length, width, and thickness of each cantilever arm were typically $440{\mu}m,\;4.5{\mu}m$, and $0.34{\mu}m$, respectively. However, the cantilevers underwent bending, a technical difficulty commonly encountered during the fabrication of electrical circuits on ultra-soft mechanical substrates. In order to circumvent this difficulty, we controlled the Ar pressure during Nb sputtering to minimize the intrinsic stress in the Nb film and studied the effect of residual stress on the resultant device.

  • PDF

A novel technique for large and ptotic breast reconstruction using a latissimus dorsi myocutaneous flap set at the posterior aspect, combined with a silicone implant, following tissue expander surgery

  • Ishii, Naohiro;Ando, Jiro;Shimizu, Yusuke;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.484-489
    • /
    • 2018
  • Large and ptotic breast reconstruction in patients who are not candidates for a transverse rectus abdominalis myocutaneous flap and revision surgery for the contralateral breast remains challenging. We developed a novel breast reconstruction technique using a latissimus dorsi myocutaneous (LD m-c) flap set at the posterior aspect of the reconstructed breast, combined with an anatomical silicone breast implant (SBI), following tissue expander surgery. We performed the proposed technique in four patients, in whom the weight of the resected tissue during mastectomy was >500 g and the depth of the inframammary fold (IMF) was >3 cm. After over-expansion of the lower portion of the skin envelope by a tissue expander, the LD m-c flap was transferred to cover the lower portion of the breast defect and to achieve a ptotic contour, with the skin paddle set at the posterior aspect of the reconstructed breast. An SBI was then placed in the rest of the breast defect after setting the LD m-c flap. No major complications were observed during the follow-up period. The proposed technique resulted in symmetrical and aesthetically satisfactory breasts with deep IMFs, which allowed proper fitting of the brassiere, following large and ptotic breast reconstruction.

A Case of Primary Reconstruction using Fibular Osteocutaneous Free Flap after Total Maxillectomy Due to Rhabdomyosarcoma (횡문근육종으로 인한 상악골 전절제술 후 유리비골골피판을 이용한 치험례)

  • Kim, Tae Hyung;Oh, Deuk Young;Lee, Paik Kwon;Kim, Min Sik;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.381-384
    • /
    • 2005
  • Rhabdomyosarcoma is a rare malignancy of head and neck region. When rhabdomyosarcoma occurs in maxillary area, total maxillectomy is necessary. Total maxillectomy causes defects of orbital floor, palate, gingiva, and alveolar bone, causing severe facial deformity and functional impairment. Immediate maxillary reconstruction has to cover both bone and soft tissue to minimize cosmetic and functional problems. The fibular osteocutaneous free flap can provide paranasal, gingiva, oral mucosal lining and foundation for dental prosthesis, thus ensuring good cosmetic results and mastication, phonation function. We have experienced a reconstruction case of a 19-year-old man with rhabdomyosarcoma of the left maxillary sinus. The patient underwent total maxillectomy and neck dissection. We designed a fibular free flap that had a vascularized bone segment and a double skin paddle. Surgical outcomes were excellent in cosmetic and functional aspects.

Design and Manufacture of a Hand-made Vehicle Based on a Formula (포뮬러 형태의 자작자동차 설계 및 제작)

  • Lee, Soo Jin;Jeong, Wonsun;Kim, Geunbi;Kim, Seong Keol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.568-575
    • /
    • 2015
  • A hand-made vehicle with a formula (VF-1) was designed and manufactured with the aim of realizing a lightweight and high-performance vehicle. The driver's body weight and stiffness of the frame were considered. The vehicle was equipped with a one-cylinder Exiv 250 engine with intake manifold potting for realizing weight reduction, high performance, and low cost. The suspension system for the formula was designed through the analyses and tests of vehicle motion and equipment. In a steering system, anti-Ackerman geometry was introduced to increase the transverse force during cornering. A full electric paddle shift system was adopted to decrease the braking distance. For protection against the distortion and warping of the frame, tungsten inert gas (TIG) welding technology was used.

Vascularized Osteocutaneous Fibular free Flap for Reconstruction of Mid Foot

  • Chung, Yoon-Kyu;Hong, Joon Pio;Kim, Sug-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.1
    • /
    • pp.75-79
    • /
    • 2000
  • The foot plays a vital role in standing and gait. This function results from harmonious interaction of bones, joints, and soft tissue. An imbalance or a defect in such structures can lead to impaired function of the foot. The mid foot, composed of cunieforms, navicular and cuboid bone, plays a vital role in maintaining longitudinal and transverse arches and injury or defects to this region can cause instability of the foot. This paper reports a case of complex foot injury; soft tissue defect of dorsum of foot, and medial and intermediate cuneiform bone defect, reconstructed in a single stage using vascularized osteocutaneous fibular free flap. Segmented to fit the defects of medial and intermediate cuneiform bones and a skin paddle providing adequate coverage, restored the stability to the arches and function of the midfoot. The fibula osteocutaneous free flap has appealing characteristics for reconstruction of the foot and the complex mid foot injuries can be considered to the long list of indications.

  • PDF

Total Maxillectomy Defect Reconstruction Using Bipedicled Scapular Osteocutaneous Free Flap: 3 Cases (전 상악골 절제술 후 양경 유리 견갑 골-피부 피판을 이용한 재건 3례)

  • Kim, Jung-Min;Ha, Bom-Jun;Mun, Goo-Hyoun;Hyun, Won-Sok;Bang, Sa-Ik;Oh, Kap-Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • We used bipedicled scapular osteocutaneous free flap for total maxillectomy defect reconstruction in 3 cases of malignant maxillary tumor. We elevated two flaps of the skin paddle and the bone flap with one common pedicle - the subscapular artery - which was devided to the angular branch of the thoracodorsal artery and the circumflex scapular artery to reconstruct the nasal cavity, the palate and the zygoma. The angle between the two flaps was free enough so that we could transfer the two flaps through a single microanastomosis. After the operation, patients could swallow and pronounce well, and the wound contracture was minimal so that we could get aesthetically good result.

  • PDF

Study on the Fabrication and Evaluation of the MEMS Based Curved Beam Air Flowmeter for the Vehicle Applications (MEMS 기반의 차량용 휨형 유속센서의 제작 및 특성 연구)

  • Park, Cheol Min;Choi, Dae Keun;Lee, Sang Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.116-123
    • /
    • 2016
  • This paper presents the fabrication and evaluation of the novel drag force type air flowmeter using MEMS technologies for the vehicle applications. To obtain the air drag force, the flowmeter utilized the curved beam structure, which was realized by the difference of residual stress between the silicon oxide layer and the silicon nitride layer. The paddle structure was applied for the maximum air drag force, and the dual-beam was adapted to prevent distortion. The basic experiments were performed in the wind tunnel, and the stable outputs were obtained. The device was applied to the internal combustion engine, and the results were compared with the HI-DS output where the convection thermal flowmeter was used as the reference sensor. The results indicated that the comparable resolutions and response times were obtained under the various engine speeds.

Full Three Dimensional Rheokinetic Modeling of Mold Flow in Thin Package using Modified Parallel Plate Rheometry (개선된 회전형 레올로지 측정법을 이용한 박형 반도체 패키지 내에서의 3차원 몰드 유동현상 연구)

  • LEE Min Woo;YOO Min;YOO HeeYoul
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.17-20
    • /
    • 2003
  • The EMC's rheological effects on molding process are evaluated in this study. When considering mold processing for IC packages, the major concerning items in current studies are incomplete fill, severe wire sweeping and paddle shifts etc. To simulate EMC's fast curing rheokinetics with 3D mold flow behavior, one should select appropriate rheometry which characterize each EMC's rheological motion and finding empirical parameters for numerical analysis current studies present the new rheometry with parallel plate rheometry for reactive rheokinetic experiments, the experiment and numerical analysis is done with the commercial higher filler loaded EMC for the case of Thin Quad Plant Packages (TQFP) with package thickness below 1.0 mm. The experimental results and simulation results based on new rheometry matches well in point of the prediction of wire sweep, filling behavior of melt front advancement and void trapping position.

  • PDF