• Title/Summary/Keyword: pad cooling systems

Search Result 19, Processing Time 0.025 seconds

The Cooling Effect of PAD Location and FAN Capacity on Greenhouse (PAD 위치 및 FAN 용량에 따른 온실의 냉방효과)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.399-404
    • /
    • 1999
  • This study were performed to find the cooling effect and to provide design data during summer season for the Pad& Fan system of greenhouse . The temperature variation along the greenhouse width were analyzed. Also, the effect of the pad location and fan capacity on the cooling of the greenhouse were analyzed. While Pad &Fan systems were operating the temperatures in greenhouse were very different along the meausring locations. It is recommeded that PAD location and FAN capacity should be considered to design the Fan and Pad system in order to provide greenhouse the optimum temperature condition.

  • PDF

Development of Night Cooling System for Greenhouse Using Cool Air and Water from an Abandoned Coal Mine (폐광의 냉기 및 냉수를 이용한 온실의 야냉 시스템 개발)

  • Kang, Whoa-Seug;Kang, Wie-Soo;Lee, Gwi-Hyun;Oh, Jae-Heun;Kim, Ii-Seop;Yoo, Keun-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night for getting up early blooming of strawberry. Various cooling systems were designed and constructed to use cool air and water from an abandoned coal mine. Cooling systems built for this study included an evaporative cooling system with cooling pad, heat exchanger using small or large radiator, and cooling duct for drawing cool air from coal mine. The cooling pad, small or large radiator and cooling duct were individually tested. Also, combined cooling system was tested by operating cooling pad, small radiator, and cooling duct simultaneously. The results in this study showed that individual cooling systems such as cooling pad, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined cooling system had little better cooling effect than individual cooling system except the large radiator. The most effective cooling system for cooling of greenhouse was obtained by using a large radiator as the heat exchanger. By using a large radiator, temperature in greenhouse was dropped into about $15^{\circ}C$ when outside temperature was $23-24^{\circ}C$ during summer night.

  • PDF

Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems (증발냉각시스템의 활용실태 및 냉방효과)

  • 김문기;유인호;김기성
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 1999
  • In order to take a good look at effectiveness of cooling of Fog system and Pad-Fan system, we chose 49 farm households which were installed evaporative cooling system and 2 farm households which were installed Pad-Fan system and Fog system for a test. We execute the test on 29 households out of 49.6 households, which were installed Pad-Fan system, were able to use; however, 6 household out of 9 which were installed Fog system couldn't use it. The main reason was the clogged on nozzle. The cooling efficiency on Pad-Fan system was 77.4%, but it was very poor on Fog system. Since there are many problems on Fog system, we need more research on size of fog, the location of nozzle, control of Fog systems.

  • PDF

Effects of Pad Cooling Systems in Tunnel-Ventilated Broiler House on Reducing Indoor Temperature and Level of Temperature-Humidity Index during Summer (국내 터널식환기 무창 육계사에서 여름철 쿨링패드 사용에 따른 계사 내부 온도 저감 효과 및 더위지수(THI)에 미치는 영향)

  • Hye Ran Kim;Seol Hwa Park;Jisoo Wi;Seongshin Lee;Sung Dae Lee;Hwan Ku Kang;Chaehwa Ryu
    • Korean Journal of Poultry Science
    • /
    • v.51 no.2
    • /
    • pp.57-63
    • /
    • 2024
  • As global warming worsens, it is feared that higher ambient temperatures and relative humidity might result in a more intense heat stress for livestock animals, especially broilers, which lack sweat glands for thermoregulation and have been selectively bred for rapid growth. Therefore, strategic livestock management is needed to mitigate the adverse effects of heat stress on broilers. In Korea's poultry farming systems, tunnel-ventilated broiler houses and pad cooling systems are commonly installed to lower indoor temperatures during the summer. However, caution is advised with pad cooling systems as they can increase the humidity inside the houses, potentially causing further harm. This study aimed to evaluate the effectiveness of pad cooling systems in tunnel-ventilated broiler house by assessing the reduction in indoor temperature using the Temperature-Humidity Index (THI), which accounts for the impact of relative humidity. Temperature and humidity data were collected during the summer (Jun to Sep) from eight farms with tunnel-ventilated broiler house located in different regions of Korea. The farms were divided into two groups based on the use of pad cooling systems is used, and temperature and humidity data, along with THI values, were analyzed two weeks before the birds were marketed. Meta-analysis results showed that at the hottest time of the day, 14:00, farms with pad cooling systems had significantly lower indoor temperatures compared to the control group, but observed an increase in indoor temperatures by 16:00 (p<0.05). There is no significant difference in relative humidity (p>0.05). The THI values decreased in the treatment group with cooling pads compared to the control group starting from 15:00, suggesting a diminished effect (p<0.05). This study indicates the potential for developing optimal operational guidelines for cooling pads to reduce heat stress in broilers during the summer season.

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

A study on development of the standard PAD-mounted type Transformer (표준형 지상변압기 개발에 관한 연구)

  • 조국희;김광화;양태권;홍원식;조양섭;김양태
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.74-77
    • /
    • 1997
  • As underground distribution systems to be operated in downtown have more merits than overhead distribution system, underground distribution systems are being increased. But when pad-mounted transformers have troubles, reptures and fires can be occurred. We think that this makes accidents and power failures of bulidings and generates malaise and a great economic loss. In order to increase the reliability of pad-mounted transformers, we have investigated transformers and understood their failure mechani는. Therefore, we would have objectives and necessities of this study to improve quality and operating condition and install switches to be able to check and maintain transformers and optimize protection devices and increase cooling effect in pad-mounted transformers.

  • PDF

The Cooling Effect of Evaporative Cooling Systems on Greenhouse (증발냉각시스템 설치 온실의 냉방효과)

  • 김기성;김문기;김현수
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.209-212
    • /
    • 1999
  • 여름철 재배시설의 기본적인 온도상승 억제방법은 차광과 환기이지만 이 방법만으로는 작물의 적정 생육온도에 접근하기 어렵기 때문에 추가적인 냉방 장치가 도입되고 있다. 현재 온실의 냉방시스템은 물의 증발잠열을 이용한 Pad and Fan 방식과 Fog 방식의 냉방시스템이 보급되어 있으나, 국내의 지역기상조건을 감안한 연구가 충분히 이루어지지 못하여 냉방시스템의 설치와 운영에 대한 기준이 명확하지 못한 실정이다. 따라서, 본 연구에서는 현장 실험을 통하여 기초적인 자료를 수집하였다.

  • PDF