• Title/Summary/Keyword: package resonance

Search Result 55, Processing Time 0.018 seconds

Finite element based dynamic analysis of multilayer fibre composite sandwich plates with interlayer delaminations

  • Jayatilake, Indunil N.;Karunasena, Warna;Lokuge, Weena
    • Advances in aircraft and spacecraft science
    • /
    • v.3 no.1
    • /
    • pp.15-28
    • /
    • 2016
  • Although the aircraft industry was the first to use fibre composites, now they are increasingly used in a range of structural applications such as flooring, decking, platforms and roofs. Interlayer delamination is a major failure mode which threatens the reliability of composite structures. Delamination can grow in size under increasing loads with time and hence leads to severe loss of structural integrity and stiffness reduction. Delamination reduces the natural frequency and as a consequence may result in resonance. Hence, the study of the effects of delamination on the free vibration behaviour of multilayer composite structures is imperative. The focus of this paper is to develop a 3D FE model and investigate the free vibration behaviour of fibre composite multilayer sandwich panels with interlayer delaminations. A series of parametric studies are conducted to assess the influence of various parameters of concern, using a commercially available finite element package. Additionally, selected points in the delaminated region are connected appropriately to simulate bolting as a remedial measure to fasten the delamination region in the aim of reducing the effects of delamination. First order shear deformation theory based plate elements have been used to model each sandwich layer. The findings suggest that the delamination size and the end fixity of the plate are the most important factors responsible for stiffness reduction due to delamination damage in composite laminates. It is also revealed that bolting the delaminated region can significantly reduce the natural frequency variation due to delamination thereby improving the dynamic performance.

Long Term Average Spectrum Characteristics of Speaking Voice of Western Operatic Singers (Long Term Average Spectrum을 이용한 성악가들의 Speaking Voice 분석)

  • Lee, Kyung-Chul;Hong, Seok-Jin;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.122-127
    • /
    • 2004
  • Background and Objectives : Many studies have described and analyzed singer's formant and it has been shown that the epilaryngeal tube in the human airway is responsible for vocal ring, or the singer's formant. A similar phenomenon produced by trained singers in their speech led some authors to examine the speaker's ring. This study was designed to analyze the speaking voice of the singers and speaker's ring. Baterials and Methods : Ten tenors, fifteen baritones, fifteen sopranos and ten mezzo sopranos attending the music college, department of vocal music were chosen for this study. Fifteen male and fifteen female untrained normal speakers were chosen for control group. Each subject was asked to produce a sample of a sustained spoken vowel /ah/ sound for at least five seconds and read sentence 'Kaeul'. The sound data was analyzed using the Fast Fourier Transform(FFT) - based power spectrum, Long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab(CSL, Kay elemetrics, Model 4300B, USA). Statistical analysis was performed using the Mann-Whitney test of the Statistical Package for Social Sciences(SPSS). Results : For LTA Power spectrum of/ah/ sound, a significant increase was seen in the 2,500-3,500Hz region(p<0.01) in four trained singer group compared with untrained speaker group, and a significant increase in the 9,000-10,000Hz region(p<0.01) in soparano group. Similarly, in sentence 'Kaeul', there was a significant increase in energy in the tenor, baritone, mezzo soprano group compared with the untrained speaker group in the 2,500-3,500Hz region(p<0.01), and a significant increase in all frequency region(p<0.01) in the soprano group. Conclusions : The LTA power spectrum suggests that trained singers group show more energy concentration in the 'singer's formant' region in the speaking voice, and authors believe this region to be the 'speaker's ring'. Further research is needed on the effect of singing training on the resonance of the speaking voice.

  • PDF

Long Term Average Spectrum Characteristics of Head and Chest Register Sounds of Western Operatic Singers : Extended Study (성악다들의 목소리에 대한 Long Term Average Spectrum 분석 -$2^{nd}$ Singer's Formant의 존재 가능성에 대하여-)

  • Ban, Jae-Ho;Kwon, Young-Kyung;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2004
  • Background and Objectives : It has been shown that the epilaryngeal tube in the human airway is responsible for vocal ring, or the singer's formant. In previous study, authors showed that in trained tenors, besides the conventional singer's formant in the region of ,5500Hz, another energy peak was observed in the region of 8,000Hz. This peak was interpreted as the second resonance of the epilarynx tube. Singers in other voice categories who produce vocal ring are assumed to have the same peak, but no measurements have as yet been made. Materials and Methods : Fifteen tenors, fourteen baritones, seven sopranos and five mezzo sopranos attending the music college, department of vocal music who could reliably produce the head and chest registers were chosen for this study. Each subject was asked to produce an/ah/sound for at least three seconds for the head register sound(tenors ; G4, barions ; E4 sopranos ; F5 and mezzosopranos ; C5) and for the chest register sound (tenors ; C3, baritones ; D3, sopranos ; D4 and Mezzosoprano ; A3). The sound data was analyzed using the Fast Fourier Transform (FFT)-based power spectrum, Long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab (CSL, Kay elemetrics, Model 4300B, USA). Statistical analysis was performed using the Mann-Whitney test of the Statistical Package for Social sciences(SPSS). Results : For head register sounds, a significant increase was seen in the 2,200-3,400Hz region(p<0.05) and the Similar to the head register sounds, there was a significant increase in energy in the four trained singer group compared with the untrained group in the 2,200-3,100Hz region(p<0.05), the 7,800-8,400Hz region(p<0.05) for the chest register sounds. Conclusions : When good vocal production was made for the head and chest registers, an energy peak was observed near 2,500Hz, a frequency already known as the "singer's formant', in all subjects in the study group. Another region of increased energy was observed around 8,000Hz that had not been noticed previously. The authors believe this region to be the second singer's formant.

  • PDF

Vibration Characteristics of the Oriental Melon by Vibration Test (진동시험에 의한 참외의 진동특성)

  • Kim, Man-Soo;Jung, Hyun-Mo;Kim, Ghi-Seok;Park, Chung-Gil
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.29-42
    • /
    • 2005
  • During a long journey of agricultural products from the production area to markets, the quality of agricultural products was always affected by some degree of vibration. The vibration input during the transportation may cause serious agricultural product injury, and this damage is particularly severe whenever the vegetable inside package is free to bounce, and is vibrated at its resonant frequency. The objectives of this study were to determine the resonant frequency of the oriental melon and to investigate the relationships between resonant frequency and physical properties of the oriental melon such as mass, volume and major and minor axes. In this study vibration testing device was constructed to determine the vibration response of the oriental melon in frequency ranges of 5 to 150 Hz. The computer program for controlling the vibration shaker and the function generator and measuring the vibration characteristics of the oriental melon was developed. The ranges of resonant frequency and peak acceleration at resonance of the oriental melon were 51 to 73 Hz and 1.24 to 1.92 G-rms, respectively. The resonant frequency and the peak acceleration decreased with the increase of the sample mass, volume, major and minor axes of the oriental melon. Multiple regression models for resonant frequency and peak acceleration of the oriental melon as a function of mass, major axis and minor axis of the sample were developed and analyzed.

  • PDF

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF