• Title/Summary/Keyword: pH distribution

검색결과 1,711건 처리시간 0.03초

A Study in Preparation of $^{113m}In$ colloid as Scanning Agent and it's Organ Distribution in Rats (주사용(走査用) $^{113m}In$ 교질(膠質)의 조제(調製) 및 흰쥐에서의 장기분포(臟器分布)에 관(關)한 연구(硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Hong, Chang-Gi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • 제3권1호
    • /
    • pp.73-82
    • /
    • 1969
  • The newly developed diagnostic method with application of $^{113}Sn-^{113m}In$ cow system ($^{113}Sn:\;T\frac{1}{2}$ 118 days, $^{113m}In:\;T\frac{1}{2}$ 1.7 hrs, 390 Kev, Single ${\gamma}$) has the remarkable advantages such as increased diagnostic ability by single large dose administration of $^{113m}In$ with no subsequent radiation hazard and shortened examining time. We reformed the research of following scope with the use of developed $^{113}Sn-^{113m}In$ cow (25 mCi) generator: The sizes of particles produced under various conditions were investigated, and possibility for application to the scannings of various organs such as brain, liver, lung, bone marrow and blood pool etc. were studied. Results: $^{113m}InCl_3$ solution eluted from diluted HCl solution (pH 1.5) passed through $^{113}Sn-^{113m}In$ generator, and there can be produced various sized particles of colloidal indium. And there observed the state of distribution of $^{113m}In$ in each organ which showed many differences according to the particle sizes of colloidal indium. The results are stated as follows: 1. The adjustment of pH is the most important factor in making the desirable particle size of colloidal indium. The colloid for blood pool showed the highest level as 7.1%/gm blood, at pH 1.7, the colloid of pH 3.5 for liver scanning showed the highest level, 88.4%, in the liver, the colloid pH 6 showed the highest level, 3.1%, in the spleen, and the colloid of pH 11.0 showed the highest level, 85.3%/gm, in the lung. 2. The colloid for liver scanning made with NaCl-NaOH system showed the highest liver uptake at pH 7.2, and at either higher or lower pH than 7.2 showed decrease of liver uptake more or less. 3. The activity of $^{113m}In$ eluted through $^{113}Sn-^{113m}In$ generator indicated over 90% in the initial 4 ml, and particularly 88.1%-86.0% in the initial 2 ml. 4. The incubation time, tempertaure and mechanical irritation related to colloid formation and coating of colloid were not the definite condition of influence.

  • PDF

The Characterization of Mass Transfer Factors in Neuroblastoma Implanted in Immunosuppressed Nude Rats (면역결핍누드쥐에 이식된 neuroblastoma에서의 물질전달에 미치는 인자의 특성)

  • ;G.R
    • Journal of Biomedical Engineering Research
    • /
    • 제15권1호
    • /
    • pp.41-50
    • /
    • 1994
  • The chemotherapy using macromolecules, i.e., monoclonal antibodies loaded with anticancer agents hasn't been successful in delivering therapeutic amount of the conjugates. The comprehensive evaluation of mass transfer factors in tumor is prerequisite for the development of the effective chemotherapy. Characterization of neuroblastoma implanted in immunosuppressed athymic nude rats was performed. Its growth kinetics, glucose metabolic rate (GMR) were measured along with the interstitial fluid pressure (IFP), blood perfusion rate (BPR) and pH distribution throughtout the tumor radius. Volume doubling time and GMR were 8.1 days(SD 0.44 day), 23.53 mg/min/100 g(SD 3.54 mg/min/100 g), respectively. The IFP in tumor center was increased with tumor volume, and approached to 3 mmHg (SD 2.6 mmHg) when the tumor was 3 cm high. The radial distribution of IFP, BPR and pH in 2 cm high tumors showed that BPR and pH were decreased, while IFP was increased as the ~ensors moved toward the tumor center. The elevated IFP, decreased BPR and pH in tumor center suggested that the delivery of conjugates might be increased by properly manipulating mass transfer factors.

  • PDF

Separation Properties of Sm/Nd with Karr Column (Karr column을 이용한 Sm/Nd 분리특성)

  • Eom Hyoung-Choon;Lee Jin-Young;Kim Sung-Don;Park Kye-Sung;Kim Jun-Soo
    • Resources Recycling
    • /
    • 제14권6호
    • /
    • pp.10-15
    • /
    • 2005
  • In this study, the separation of samarium to neodymium with Karr column was investigated. Separation properties of Sm/Nd binary system was estimated with experimental parameters such as flow rate, initial pH of aqueous phase, saponification of PC88A in organic phase and agitation speed. The extraction rate and distribution coefficient increased with increasing initial pH of aqueous phase at 16.5 ml/min(retention time 10 minute) of flow rate of organic and aqueous phase, and equilibrium pH of aqueous phase after extraction was maintained at 1.5 by saponified PC88A. Also, the extraction rate and distribution coefficient were drastically increased with increasing saponification degree of PC88A and agitation speed, and optimal saponification degree was $40\%$. Extraction rate of Nd and Sm was $19.6\%$ and $72.5\%$ respectively at retention time 10 minute, initial pH 1, saponification degree $40\%$ and agitation speed 120 rpm.

The Optimum pH of Oxidoreductases: A Comparison Between Experimental and Calculated pH Optimum (산화환원 효소의 최적 pH 예측)

  • Kim, Jin Ryeon;Yang, Ji Hye;Yu, Yeong Je
    • Journal of the Korean Chemical Society
    • /
    • 제46권5호
    • /
    • pp.432-449
    • /
    • 2002
  • For various oxidoreductases, the optimum pHs of the enzymes can be calculated using the rule based on proton transfer. Relative probability of a certain amino acid side chain to be in the water, or the relative affinity to the water was calculated using Boltzman distribution. Also, the protonated and deprotonated portions of a certain amino acid side chain were calculated using p$K_R$ of that and the effective protonated and deprotonated protions were the product of relative probability and the protonated and deproteonated protions. Where the total effective protonated portion was equal to the effective deprotonated portion of amino acid side chains, it was expected that oxidoreductases have max-imum activities. The optimum pHs calculated by our rule were compared with the experimental results.

Effects of Salinity on Chlorophyll Fluorescence from Porphyra Thalli and Comparison of Species with Different Intertidal Distribution

  • Hong Dang Diem;Kim Tae Hoon;Hwang Mi Sook;Chung Ik Kyo;Lee Choon-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • 제1권1호
    • /
    • pp.122-128
    • /
    • 1998
  • Characteristic changes in chlorophyll fluorescence from thalli of red alga, Porphyra, under high salt stress and during subsequent recovery were investigated, and the differences in the sensitivity to the stress among four species of Porphyra with different intertidal distributions were compared. By the treatment of NaCl with $9\%$ or higher concentrations, photochemical efficiency (Fv/Fm) decreased in a biphasic pattern: a rapid decrease was observed within 1­3 h and followed by a slow decline. The decrease of Fv/Fm was mainly due to the increase of Fo without significant increases of Fm. When the thalli treated with $15\%$ NaCl for 6 h were returned to natural sea water for recovery, the increase of Fv/Fm also showed a biphasic pattern: a rapid increase of Fv/Fm was observed within 2 h and followed by a slow increase. Differences in the sensitivity to salt stress among the four species could be found during recovery after the treatment of severe salt stress. After the treatment of $20\%$ NaCl for 6 h, Fv/Fm decreased below 0.3 in all of the four Porphyra species, and the species living in upper parts of the intertidal zone (P. suborbiculata and P. pseudolinearis) could recover better compared with the species in lower parts of the intertidal zone (P. seriata and P. yezoensis), during recovery for 24 h. The species collected from the coast of the South Sea seemed to be more tolerant than those in the East Sea.

  • PDF

An Conceptual Design for the On-Line Automatic Distribution system Database using Objected-Oriented Concept (객체지향형 실시간 배전자동화시스템 데이터베이스 구축을 위한 개념디자인)

  • Choi, S.Y.;Kim, J.H.;Shin, M.C.;Nam, S.B.;Park, N.O.;Lee, B.K.;Cho, P.H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1137-1139
    • /
    • 1998
  • Effective database is the key to manage automatic distribution system. Currently, automatic distribution system database has been studied with a relational concept. But, it is hard to describe the characteristic of automatic distribution system data which require real time management and composite type. This paper present the way how to design conceptual schema for EMS database using object-oriented concept which is free to decribe composite data type and support inheritance concept.

  • PDF

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

Removal Characteristics of Copper from Anthraquinone Dyes by Iron Cementation (안트라퀴논계 염료에서 철 교착반응에 의한 구리의 제거 특성)

  • 천재기;이석희;주창식
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • 제20권1호
    • /
    • pp.45-53
    • /
    • 2002
  • The removal of chelated copper from anthraquinone dyes by cementation on powdered iron was studied. The removal of chelated copper was found to be a function of solution pH, amount of NTA and iron, and reaction temperature. In the presence of NTA, reaction rate of cementation was found to be strongly dependent on reaction temperature, solution pH, amount of NTA and amount of iron powder. These experimental results can be explained successfully by the distribution of complexed copper iron in solutions.

  • PDF

The Characteristics of pH Variations and Lead transport during Electrokinetic Remediation of soil Contaminated by Heavy Metal (중금속 오염토의 Electrokinetic 정화 처리시 pH 발현과 납 제거의 전극 간 특성)

  • 한상재;김수삼
    • Journal of Soil and Groundwater Environment
    • /
    • 제6권4호
    • /
    • pp.13-23
    • /
    • 2001
  • In this study, the characteristics of pH variations and contaminant distribution in soil are investigated during electrokinetic treatment for the purpose of restoring contaminated soil with heavy metal. For these objects, laboratory test for the kaolin contaminated by lead was performed. During electrokinetic treatment, lead was transported from anode to cathode. And 75% of lead removed within 80% region of the specimen. Most lead, however, that transported from anode to cathode precipitated in the vicinity of cathode compartment, thus the amount of lead removed by electroosmosis was little. Electrokinetic treatment satisfied regulation criteria of Korean Soil Environment Conservation Law within almost region of the specimen. But enhancement methods can be regarded as inevitable requisite for the cathode region.

  • PDF