• Title/Summary/Keyword: pH detection

Search Result 1,102, Processing Time 0.025 seconds

Properties and Environmental Effects Estimation of Grout Using Set Accelerating Agent Made From Calcium Aluminate and Viscosity Agent (칼슘알루미네이트계 급결재와 증점제를 사용한 그라우트의 특성 및 환경영향 평가)

  • Heo, Hyung Seok;Yi, Seong Tae;Noh, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.122-129
    • /
    • 2012
  • In this study, environmental problems(i.e., pH elevation and $Cr^{6+}$ detection) occurred by using the cement grout made from CA(calcium aluminate) were evaluated using viscosity agents(MC, chelate polymer). Ordinary portland cement and blaste-furnace slag cement were used by main materials and ACC(blended mixture of calcium aluminate) were used by accelerator for hardening of grout. In addition, viscosity agents were used for preventing pH elevation and heavy metal detection from grouting materials. From the results, it was noted that when chelate polymer was used, pH elevation and $Cr^{6+}$ detection were minimized. However, other cases showed higher pH elevation and $Cr^{6+}$ detection. At test 1 day, $Cr^{6+}$ detection with age presented over 97% of total value and, after that, additional increase was not distinct. As a result of this study, it was acknowledged that, to control pH elevation and heavy-metal (like $Cr^{6+}$) detection, the usage of BSC and chelate polymer is a very useful fact.

Development of Microfluidic Polydiacetylene Sensor Chip for pH detection (pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발)

  • Hwang, Hyun-Jin;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF

Esophageal pH and Combined Impedance-pH Monitoring in Children

  • Shin, Myung Seok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.1
    • /
    • pp.13-22
    • /
    • 2014
  • Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detection of liquid, gas or mixed reflux in addition to acid, weakly acidic or weakly alkaline reflux. MII-pH monitoring can record the direction of flow and the height of reflux, which are useful parameters to identify an association between symptoms and reflux. However, the technique is limited by its high cost and the lack of normative data of MII-pH in the pediatric population. Despite certain limitations, MII-pH monitoring will become more common and gradually replace pH monitoring in the future, because pH monitoring is part of MII-pH.

Detection of residual antibiotics by TLC and EEC-4 plate method in slaughtered pigs (도축돈에서 TLC와 EEC-4 plate법을 이용한 항생물질 잔류조사)

  • 권오성;김순태;김영욱;손재권
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.3
    • /
    • pp.313-321
    • /
    • 1997
  • The antibiotic residues of the urine, the liver, the lung, the kidney and the spleen in slaughtered pigs at Kyongbuk province were detected by TLC(505 kit) and EEC-4 plate method. 1. The positive rate of residual sulfamethazine which was detected by 505 kit in the urine (n=200) was 0.0%. 2. The positive rate of residual sulfamethazine which was detected by EEC-4 plate in the urine (n=126), the liver(n=98), the kidney(n=72), the spleen (n=68) and the lung(n=48) were 63%, 49%, 36%, 34% and 24%, respectively. 3. By EEC-4 plate method, the positive detection rates of the urine were 53.0% in BS(pH 6.0), 29.0% in BS(pH 7.2), 11.5% in BS(pH 8.0) and 13.0% in ML(pH 8.0) medium, that of the liver 41.5% in BS(pH 6.0), 22.0% in BS(pH 7.2), 6.5% in BS(pH 8.0) and 5.0%, in ML (pH 8.0) medium, that of the lung 21.0% in BS(pH 6.0), 9.5%, in BS(pH 7.2) and 8.5% in BS(pH 8.0) medium, and that of the kidney 31.5% in BS(pH 6.0), 14.5% in BS(pH 7.2), 20.0% in BS(pH 8.0) and 3.0% in ML(pH 8.0) medium. In the spleen, only in BS(pH 6.0) medium the positive rate was detected as 33.5 %. 4. The positive rates of samples which shown TLC-positive detected by EEC-4 plate method were 53.9% in no band, 77.8% in one band, 80.9% in two bands, 66.7% in three bands, respectively. In conclusion, the EEC-4 plate method could be applied for the detection of residual antibiotics in samples which shown as out of standard Rf values by TLC-method (SOS kit).

  • PDF

Detection Capability by Change of Amylograph Characteristics of Irradiated Black Pepper (방사선 조사된 검은후추가루의 Amylograph Characteristics의 변화에 따른 검지 가능성)

  • Yi, Sang-Duk;Oh, Man-Jin;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.195-199
    • /
    • 2001
  • A study was carried out to establish a detection method for irradiated black pepper using amylograph characteristics. The maximum viscosity, viscosity at $93^{\circ}C$, viscosity after 15 min at $93^{\circ}C$, viscosity at $45^{\circ}C$, viscosity after 30 min at $45^{\circ}C$, and viscosity after 60 min at $45^{\circ}C$ decreased with increasing irradiation doses, but initial pasting temperatures, maximum viscosity temperatures, breakdown, setback, and consistency did not show great changes. The high correlation coefficients $(R^2>0.97)$ were shown between irradiation doses and amylograph characteristics except for breakdown $(R^2>0.75)$, setback $(R^2>0.88)$ and consistency $(R^2>0.31)$. These results suggest that detection of irradiated black pepper is possible using amylograph characteristics.

  • PDF

Analysis of Anions by Indirect Photometric Detection (I) (간접 분광 검출법에 의한 음이온의 분석(I))

  • Park, Man-Ki;Kim, Bak-Kwang;Park, Jeong-Hill;Kim, Kyoung-Ho;Lee, Mi-Yung;Jung, Jae-Eun
    • YAKHAK HOEJI
    • /
    • v.34 no.3
    • /
    • pp.215-218
    • /
    • 1990
  • An ion chromatographic method based on indirect photometric detection of UV transparent anions was developed. Separation of anion was accomplished on strong anion exchange column (Waters SAX) using UV detector at 254 nm. Among examined UV-active additives (Dns-H, Dns-glu, Dnsser, Dns-val), Dns-glu showed the highest sensitivity. Studies on the effects of the pH and ionic strength of eluent revealed that the increase of pH and ionic strength of the eluent decreased capacity factor. The best eluent for the separation of acetate, fluoride, chloride, nitrate and bromide was $1\;{\times}\;10^{-4}M$ Dns-glu in 5 mM phosphate buffer (pH 6.30). The detection limit of chloride ion was 2.1 ng in this condition.

  • PDF

Bioluminescent Assay of Bovine Liver Riboflavin Kinase Using a Bactreial Luciferase Coupled Reaction

  • Cho, Ki-Woong
    • Journal of Microbiology
    • /
    • v.38 no.2
    • /
    • pp.74-79
    • /
    • 2000
  • For the demonstration of a novel riboflavin kinase assay method based on the bacterial bioluminescence, partially purified riboflavin kinase was prepared from bovine liver through ammonium sulfate precipitation and DEAE-cellulose ion exchange chromatography. Using bacterial luciferase from Photobacterium phosphoreum and the dithionite reduction method, and easy, safe, and fast assay method was established. The optimal temperature, pH, Km values form riboflavin and ATP of boving liver riboflavin kinase determined with this luminescence method were 35$^{\circ}C$, pH 7, 15.3${\mu}$M and 8.3.${\mu}$M, respectively. The detection limit of FMN produced by riboflavin kinase was in the range of 200 pM to 4${\mu}$M which is comparable to the HPLC-fluorescence detection method, while the detection time for each assay was less than 15 sec compared to the HPLC method which requeires at least 10 min for completion.

  • PDF

Electrochemical Sensing of Hydrogen Peroxide Using Prussian Blue@poly(p-phenylenediamine) Coated Multi-walled Carbon Nanotubes

  • Young-Eun Jeon;Wonhyeong Jang;Gyeong-Geon Lee;Hun-Gi Hong
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.5
    • /
    • pp.339-347
    • /
    • 2023
  • In this study, a nanocomposite of multi-walled carbon nanotubes@poly(p-phenylenediamine)-Prussian blue (MWCNTs@PpPD-PB) was synthesized and employed for the electrochemical detection of hydrogen peroxide (H2O2). A straightforward approach was utilized to prepare an electrochemical H2O2 sensor using a MWCNTs@PpPD-PB modified glassy carbon electrode, and its electrochemical behavior was investigated through techniques such as electrochemical impedance spectroscopy, cyclic voltammetry, and amperometry. The modified electrode displayed a favorable electrocatalytic response towards the reduction of H2O2 in an acidic solution. The developed sensor exhibited linearity in the concentration range of 0.005 mM to 2.225 mM for H2O2, with high sensitivity (583.6 ㎂ mM-1cm-2) and a low detection limit (0.95 ㎛, S/N = 3) at an applied potential of +0.15 V (vs. Ag/AgCl). Additionally, the sensor demonstrated excellent selectivity, reproducibility, and stability. Moreover, successful detection of H2O2 was achieved in real samples.

Research on an Engagement Level Underwater Weapon System Model with Neyman-Pearson Detector (Neyman-Pearson 표적 탐지기를 적용한 수중 무기체계 교전수준 모델 개발 연구)

  • Cho, Hyunjin;Kim, Wan-Jin;Kim, Sanghun;Yang, Hocheol;Lee, Hee Kwang
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.89-95
    • /
    • 2019
  • This paper introduces the simulation concepts and technical approach of underwater weapon system performance analysis simulator, especially focused on probabilistic target detection concepts. We calculated the signal excess (SE) value using SONAR equation, then derived the probability density function(PDF) for target presence($H_1$) or absence($H_0$) cases, respectively. With the Neyman-Pearson detector criterion, we got the probability of detection($P_D$) while satisfying the given probability of false alarm($P_{FA}$). At every instance of simulation, target detection is decided in the probabilistic perspective. With the proposed detection implementation, we improved the model fidelity so that it could support the tactical decision during the operation.

Implementation of Multichannel LAPS and Measurement System for Detection of the pH Variation Using an Implemented Device. (다채널 LAPS 제작 및 이를 이용한 pH 변화량 검출 시스템 구현)

  • Bae, Sang-Kon;Park, Il-Yong;Park, Young-Sik;Jang, Soo-Won;Lee, Sung-Ha;Kang, Shin-Won;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.239-249
    • /
    • 2001
  • LAPS is a device which is dependent on the bias potential between a pH sensitivity and alternating photocurrent. We implemented the multichannel LAPS device and the detection system which was able to effectively measure the sensor's output by a synchronized detection circuit and multiple methods. The implemented LAPS was structured the multiple sensing sites for analyzing a various components simultaneously. And the system included a time-division method using one pre-amplifier being able to detect the multichannel pH concentration preserving a high S/N ratio and a control part. System hardware consists of a pre-amplifier, digital unit and sensor unit, and software consists of a system program and PC program. As results, we verified the successful operations of system including an implemented pre-amplifier and signal processing units.

  • PDF