• Title/Summary/Keyword: pH 순환 시스템

Search Result 59, Processing Time 0.029 seconds

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

Properties of Steel Corrosion as a Hydration of Mortar with Calcium Aluminate Cement (알루민산칼슘 시멘트를 사용한 모르타르의 수화도에 따른 철근 부식 특성)

  • Min-Cheol Shin;Ki-Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.214-221
    • /
    • 2024
  • The present study concerns the resistance of calcium aluminate cement (CAC) to steel corrosion. The corrosion behavior of steel, chloride binding/buffering and chloride transport were evaluated in order to predict the risk of steel corrosion. The CAC mortar exhibited no corrosion on steel, irrespective of the curing temperature and CAC types, whereas ordinary Portland cement (OPC) showed a severe corrosion on the steel surface. The chloride binding capacity of CAC found to be was lower than that of OPC, yet buffering capacity against pH decrease was found to be significantly higher in the CAC paste. Furthermore, chloride ingress at all depths was found to be reduced in CAC, thereby reducing the risk of corrosion.

Development of Drainage Water Disinfection System by Electric Shock in Recirculating Soilless Culture (순환식 수경재배에서 배액의 전기충격살균법 연구)

  • Lee, Mun Haeng;Kim, Sung Eun;Lee, Sang Don;Lee, Jae Eun;Kim, Hak Sun;Cho, Suk Keong;Sim, Sang Youn;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This study was conducted to develop the disinfection system using electric shock for recycled nutrient solution in recycling soilless culture. Stainless steel (SUS 316) was found as the most appropriate electrode material for electrical disinfection system from the view of high electrical conductivity, low electric resistance, and low price. There were no changes in nutritional elements when the electric shock passed through the nutrient solution by stainless steel electrode. The amount of electric current increased with width than thickness of the electrode. The farther the distance between the electrodes was increased the time to reach out the aimed amount of current. The electric shock was applied to Ralstonia solanacearum and Fusarium oxysporum as representative bacteria and also fungi. Any of those pathogens were killed with the percentage of higher than 97% in the condition of 15VDC or 24VDC.

Study on the Recycled Compositing System for Reducing Bulking Agent Cost (부자재 비용절감을 위한 순환퇴비화 시스템에 관한 연구)

  • 최명환;홍지형;박금주;최원춘
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.191-199
    • /
    • 2000
  • This study was initiated to investigate the influence of biophysical condition on the composting characteristics, and conducted to develop technology for using recycled compost as a bulking agent cost to reduce operating cost. To methods of aeration, continuous aeration (CA: run No. I) and intermittent aeration (IA: run No. 2) were performed with three 12.3 liter laboratory scale vessels for ten days. Manure and rice hulls were mixed for thirst trial (I), rice hulls and recycled compost after first trial were mixed for second trial (II), dairy manure and only recycled compost after second trial were mixed for third trial (III). During the composting process, temperatures of the compost mass and ammonia emissions were measured. The quality and maturity of compost were ascertained by examining the characteristics and composition of the compost. Also, loss of mass was determined by measuring the mass of materials in the vessels before and after composting. The results in this study are as follows: 1. The periods of optimum temperature ($>55^{\circ}C$) to kill pathogens were maintained from 38 to 78 hours for CA and from 60 to 98 hours for IA. 2. The more recycled compost mixed, the more ammonia emitted. The maximum ammonia emissions were 287 ppm at CA and 420 ppm at IA. 3. Biofiltration system was required for the compo sting system using only recycled compost as an amendment, because the ammonia emissions was produced above 100 ppm at the end of composting process. 4. The quality and maturity of compost: - Fresh compost, were required drying, because moisture contents of the compost were approximately 70% in all tests. - The pH values were observed to rise smoothly, from 7.9 to 8.3 at CA and from 8.4 to 8.6 at IA. The CfN ratios of the fresh compost were ranged form 21.05 to 16.42 for CA and from 22.81 to 14.75 for IA. The final C/N ratios for test II and III were below 20.were below 20.

  • PDF

Growth Characteristics of Common Ice Plant (Mesembryanthemum crystallinum L.) on Nutrient Solution, Light Intensity and Planting Distance in Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 배양액, 광도 및 재식거리에 따른 Common Ice Plant의 생육 특성)

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • This study was conducted to determine the optimum nutrient solution, pH, irrigation interval, light intensity and planting density to growth of common ice plant (Mesembryanthemum crystallinum L.) in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-h photoperiod were used. Nutrient film technique systems with three layers were used for the plant growth system. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Treatments were comparison of the nutrient solution of Horticultural Experiment Station in Japan (NHES) and the nutrient solution of Jeju National University (NJNU), pH 6.0 and 7.0, irrigation interval 5 min and 10 min, light intensity 90 and $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and within-row spacing 10 cm, 15 cm, 20 cm and 25 cm with between-row spacing 15 cm. Optimum macronutrients were composed N 7.65, P 0.65, K 4.0, Ca 1.6 and Mg $1.0mM{\cdot}L^{-1}$. There were no significant interactions between pH 6.0 and 7.0 about shoot fresh weight and shoot dry weight of common ice plant. Irrigation interval 5 min and 10 min was also the same result. Shoot fresh weight and shoot dry weight were highest at $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Shoot fresh weight and shoot dry weight were decreased according to increasing the planting density. From the above results, we concluded that optimum nutrient solution, optimum levels of pH, irrigation interval, light intensity and planting density were 6.0-7.0 and 10 min, $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and $15{\times}15cm$, respectively for growth of common ice plant in a closed-type plant production system.

Environmental Effect of the Reduced Slag in the Electric Furnace (전기로 제강 환원슬래그 혼합토의 환경적 영향)

  • Na, Hyunsu;Yoon, Yeowon;Yoon, Gillim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.7
    • /
    • pp.23-29
    • /
    • 2011
  • The oxidation slag has been widely used in civil engineering project, whereas the reduced slag from electric furnace has yet to be applied. Consequently in order to find out the recycling method in civil engineering field, the mineral compositions of the reduced slag were analyzed and some tests on water quality were performed to estimate the potential release of toxic compounds. Slag-soil mixtures of 0, 10, 20 and 30%(dry weight) soil were prepared in lysimeter columns and the effluents were collected with the period of one, two and four week options in closed system, respectively. The result from qualitative and quantitative analysis using X-ray Diffraction(XRD) and X-ray Fluorescence(XRF) indicates that the main mineral of the reduced slag is $Ca_2(SiO_4)$, a kind of calcium silicate. Also, the leaching medium analyzed by Inductively Coupled Plasma Optical Emission Spectroscopy(ICP-OES) showed that main heavy metals such as Al, Fe and Mn are included in the reduced slag due to the effect of steel production process. It can be seen that the leachate does not violate the regulation guide line of waste material of heavy metal. Also the pH levels were increased from pH 6.9 for 0% soil to pH 10 for 30% soil. However the influence on leachate circulation period of one through four weeks was negligible.

Compact $H_2$ PSA process for Hydrogen station (수소 station을 위한 Compact형 $H_2$ PSA 공정 실험)

  • Lee, Jang-Jae;Woo, Eun-Ji;Kim, Myung-Jum;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.118-121
    • /
    • 2007
  • 수소 스테이션의 수소분리정제를 위한 Compact 형 PSA를 연구하였다. 수소 스테이션의 공정과정 중에서 수소 분리를 위한 PSA 장치는 에너지효율면에서 장점을 가지고 있지만 부피가 커서 많은 부지를 차지하는 단점이 있다. 수소 PSA의 이러한 단점을 줄이기 위하여 하나의 흡착탑 안에 다른 흡착탑을 넣는 Dual bed 형태의 Compact형 수소 PSA공정을 연구하였다. Compact형 수소 PSA는 하나의 bed안에 다른 하나의 bed를 넣음으로써 시스템이 차지하는 부피를 줄이는 한편, inner bed와 outer bed사이의 열교환 효과가 나타나기 때문에 그 효율을 높일 수가 있다. Compact형 Dual bed는 활성탄으로 충진하였고 공급 기체로는 4성분 수소 혼합물 ($H_2/CO/CH_4/CO_2$, 69:2:3:26 vol.%)를 사용하였다. 흡착탑의 동특성을 알아보기 위하여 공급유량 7LPM, 흡착압력 9atm의 조건으로 파괴 실험을 수행하였다. 또한, Compact형 흡착탑의 열교환 효과가 PSA공정에 미치는 영향을 보고자 한 쪽 탑에서 흡착을 할 때, 다른 탑에서 탈착이 일어나는 실험을 하였다. 그리고 P/F ratio에 따라 Compact형 PSA 공정 실험을 하고 Compact형 흡착탑과 같은 부피의 일반 두 탑 PSA 공정을 시뮬레이션 값과 비교함으로써 Compact형 PSA의 성능을 알아 보았다. 그 결과 Dual bed PSA는 작은 부피를 차지하는 장점뿐만 아니라 열적 효과로 인하여 기존의 단일 흡착탑 PSA에 비하여 보다 높은 효율을 나타내면서 우수한 수소 분리 성능을 보여주었다.

  • PDF

Characterizing CO2 Supersaturation and Net Atmospheric Flux in the Middle and Lower Nakdong River (낙동강 중하류에서 이산화탄소 과포화 및 순배출 특성 분석)

  • Lee, Eun Ju;Chung, Se Woong;Park, Hyung Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.416-416
    • /
    • 2019
  • 육상 담수는 대기중 이산화탄소($CO_2$) 배출의 중요한 발생원으로 주목되고 있다. 하천 및 강에서 대기중으로 배출되는 $CO_2$는 전 세계 탄소순환의 핵심요소이며, 대부분의 하천과 강은 $CO_2$로 과포화 되어있다. 세계적으로 하천 및 강의 $CO_2$ 배출량은 호수 및 저수지의 배출량보다 약 5배 많은 것으로 보고되고 있으나, 국내연구에서는 연구사례가 드물다. 따라서 본 연구의 목적은 낙동강 중하류에 위치해있는 강정고령보(GGW), 달성보(DSW), 합천창녕보(HCW), 창녕함안보(CHW)에서 발생되는 순 대기 배출 플럭스(Net Atmospheric Flux, NAF)의 동적 변동 특성을 분석하고, 데이터마이닝 기법을 적용하여 쉽게 수집할 수 있는 물리적 및 수질 변수로 $CO_2$ NAF를 추정하는데 사용할 수 있는 간략한 예측 모델을 개발하는데 있다. $CO_2$ NAF는 대기-수면 경계면에서의 $CO_2$ 부분압($pCO_2$)의 차에 기체전달속도를 곱하여 산정하였으며, 기체전달속도는 Cole and Caraco(1998)가 제안한 식을 사용하였다. 담수와 해수의 탄산염 시스템에서 열역학적 화학평형을 모두 고려한 $CO_2$SYS 프로그램을 사용하여 수중의 $pCO_2$를 산정하였고, $CO_2$ NAF는 Henry의 법칙과 Fick의 1차 확산법칙을 사용하여 계산하였다. $CO_2$ NAF의 시간적 변동성에 영향을 미치는 환경요인을 평가하기 위해서 상관분석, 주성분분석(Principal Component Analysis; PCA), 단계적다중회귀모델(Step-wise Multiple Linear Regression; SMLR), 랜덤포레스트(Random Forest; RF)방법을 사용하였다. SMLR 모델은 R package인 olsrr, RF 모델은 R package인 caret, randomForest를 이용하여 분석하였다. 연구 결과, 4개 보 상류 하천구간은 조류의 성장이 활발한 일부 기간을 제외한 대부분의 기간에서 $CO_2$를 대기로 배출하는 종속영양시스템(Heterotrophic system)을 보였다. $CO_2$ NAF의 중위값은 HCW에서 최소 $391.5mg-CO_2/m^2day$, DSW에서 최대 $1472.7mg-CO_2/m^2day$였다. 모든 보에서 NAF는 pH와 강한 음의 상관관계를 보였으며, $pCO_2$와 Chl-a도 음의 상관관계를 보였다. 이는 조류가 수중에서 $CO_2$를 소비하고 pH를 증가시키기 때문이다. PCA 분석 결과, NAF와 $pCO_2$가 높은 공분산을 보였으며, pH와 Chl-a는 반대 방향으로 군집되어 상관분석과 동일한 결과를 보였다. 이 연구를 통해 개발된 SMLR 모델과 RF 모델의 Adj. $R^2$ 값은 모든 보에서 0.77 이상으로 나왔으며, $pCO_2$ 측정 데이터가 없더라도 하천의 $CO_2$ NAF를 추정하는 방법으로 사용될 수 있을 것으로 평가된다.

  • PDF

Control of Several Fungi in the Recirculating Hydroponic System by Modified Slow Sand Filtration (재순환 양액재배시 저속 모래여과기 시스템을 이용한 진균류 제어)

  • Park, K.W.;Lee, G.P.;Kim, M.S.;Lee, S.J.;Seo, M.W.
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.347-349
    • /
    • 1998
  • Slow sand filtration was modified and applied for the determination of eliminating efficacy of various fungi and for recommending an easy approach to growers. After 1,500 liter filtration, Fusarium oxysporum was eliminated by several substrates such as activated charcoal (92.5% elimination), silica (90.8%), vermiculite (90.5%), sand (82.3%), perlite (50.4%), and hydroball (21.2%). Silica was able to eliminate several fungi by maximal ratio, which was corresponded to Fusarium oxysporum 120 cfu/mL. Collectotrichum lagenarium 98 cfu/mL. Phytophthora capsici 82 cfu/mL, Botrytis cinerea 62 cfu/mL, Pythium spp. 42 cfu/mL, and Sclerotinia ssp. 52 cfu/mL. In this case, the change of EC was minor and pH was maintained to about 7. In deep flow culture of 'Ddooksum Cheokchookmyeon' lettuce and 'Seokwang' tomato, silica-, activated charcoal-, and vermiculite-based filtration system successfully eliminated Fusarium oxysporum and Phytophthora capsici from the nutrient solution. As a result, these plants were not diseased by ten weeks after inoculation. With this system, growers can easily control the root-zone fungi in the recirculating hydroponic system.

  • PDF

Preliminary Study on the Recycled Composting System for Reducing Bulking Agent Cost (부자재 비용 저감을 위한 순환 퇴비화 시스템의 예비연구)

  • 홍지형;최명환;박금주
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.405-410
    • /
    • 1999
  • This study was performed to find the recycling performance and to provide design data during recycle solid composting system to reduce bulking agent cost, Dairy manure amended with rice hulls and recycled compost was composted in a laboratory -scale vessel by continuous aeration for 10 days. The temperature and ammonia emission variations according to the ratios of bulking agents during the primary aeration stage were surveyed. Also, the influence of fresh compost quality on the recycling performance were anlayzed. While recycled composting system were operatured. The temperature in compost was maintained in the range of 40∼60$^{\circ}C$ needed for biodegradation and death of pathogenic organisms, but the ammonia emission was different by the ratios of recycled compost. The ammonia emission increased due to the low C/N ratio(17.6), high pH value(8.1) of the recycled compost.

  • PDF