• 제목/요약/키워드: pCR

검색결과 1,873건 처리시간 0.03초

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

  • Kim, Jung Gon;Han, Sang-Woong;Yi, Joo Hark;Park, Hyeong Cheon;Han, Sang Youb
    • Nutrition Research and Practice
    • /
    • 제14권1호
    • /
    • pp.25-31
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS: Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS: Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS: Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.

Na-A형 제올라이트의 합성 및 중금속에 대한 흡착능 (Synthesis of Na-A Type Zeolite and Its Ability to Adsorb Heavy Metals)

  • 채수천;장영남;배인국;이성기;류경원
    • 한국광물학회지
    • /
    • 제21권1호
    • /
    • pp.37-44
    • /
    • 2008
  • 본 연구는 마포소각장에서 발생된 용융슬래그로부터 Na-A형 제올라이트를 합성하여 환경 저감재로 재활용키 위한 목적에서 수행되었다. 초기물질로 사용된 용융슬래그는 용제(flux)로 사용된 Fe 성분(19.6% of $Fe_2O_3$, and 18.9% of FeO)이 비교적 높기는 하지만, 상대적으로 제올라이트의 주요 성분인 $SiO_2$, $Al_2O_3$$Na_2O$가 각각 26.6%, 10.9% 및 2.7% 함유되어 제올라이트의 합성에 유리한 조성을 가지고 있다. 제올라이트의 수열합성은 $80^{\circ}C$에서 수행되었으며, $SiO_2/Al_2O_3\;=\;0.80{\sim}1.96$인 넓은 범위의 화학조성에서 Na-A형 제올라이트가 합성되는 것을 확인하였다. 제올라이트의 양이온 교환 능력은 10 h 이상의 합성시간에서 일정하게 거의 220 cmol/kg인 것으로 측정되었다. 합성된 제올라이트의 중금속 (As, Cr, Cd, Cu, Mn 및 Pb)에 대한 흡착능을 측정한 결과, As 및 Cr을 제외한 모든 중금속에서 높은 흡착율을 보였다. As와 Cr은 Eh-pH분석을 통해 각각 $HAsO_4^{2-}$$CrO_4^{2-}$인 이온상으로 존재하고 있음을 확인하였다. As와 Cr에 대한 제올라이트의 흡착률이 낮은 것은 이들 이온상들의 크기가 Na-A형 제올라이트의 pore size ($4\;{\AA}$)보다 상대적으로 큰 유효 이온반경($4\;{\AA}$, 직경 $8\;{\AA}$)을 가지고 있기 때문인 것으로 결론지었다.

GMA용접 중 Cu-P와 Cu-Cr계 콘택트팁의 경도와 전기전도도 변화 (Variation of Hardness & Electrical conductivity for Cu-P and Cu-Cr Contact Tips During GMA Welding Process)

  • 김가희;김희진;김남훈;유회수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.191-193
    • /
    • 2004
  • GMA(Gas Metal Arc)용접에서는 콘택트 팁이 토치 선단에 위치하여 용접 와이어를 송급하여 준다. 이러한 콘택트 팁의 주된 기능은 용접 전류를 와이어에 전송시켜주고, 와이어를 용접하고자 하는 위치로 유도하는 것이다. (중략)

  • PDF

BLACK HOLE-IGM FEEDBACK, AND LINKS TO IGM FIELDS AND CR'S

  • KRONBER PHILIPP P.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.501-507
    • /
    • 2004
  • The uniquely large dimensions of Giant radio galaxies (GRGs) make it possible to probe for stringent limits on total energy content, Faraday rotation, Alfven speeds, particle transport and radiation loss times. All of these quantities are more stringently limited or specified for GRG's than in more 'normal' FRII radio sources. I discuss how both global and detailed analyses of GRG's lead to constraints on the CR electron acceleration mechanisms in GRG's and by extension in all FRII radio sources. The properties of GRG's appear to rule out large scale Fermi-type shock acceleration. The plasma parameters in these systems set up conditions that are favorable for magnetic reconnection, or some other very efficient process of conversion of magnetic to particle energy. We conclude that whatever mechanism operates in GRG's is probably the primary extragalactic CR acceleration mechanism in the Universe.

플라즈마 용사된 $\textrm{Cr}_2\textrm{O}_3$ 층의 연삭특성 (Grinding Characteristics of the Plasma-Sprayed $\textrm{Cr}_2\textrm{O}_3$ Coating Layer)

  • 김병희;서동수
    • 한국재료학회지
    • /
    • 제9권1호
    • /
    • pp.18-24
    • /
    • 1999
  • This study was performed to observe the surface roughness and microstructural change of the grinding surface of plasma sprayed $Cr_2$$O_3$coating layer. The experimental condition were particle size of diamond grinding stone, depth of cut, rotating speed and coolant feed. As a results, the grinding conditions influencing on the surface roughness and microstructure were depth of cut and the particle size of diamond grinding stone. In addition to the conversion of brittle-ductile fracture of grinding surface on depth of cut is $5~10\mu\textrm{m}$ and rotating speed was 100 r.p.m after grinding

  • PDF

$MgO-Cr_2O_3-TiO_2$ 산화물의 가스감지 특성 (Gas Sensing Properties of $MgO-Cr_2O_3-TiO_2$ Oxide)

  • 양천회;홍필선;유일증;임병오
    • 한국안전학회지
    • /
    • 제1권1호
    • /
    • pp.21-26
    • /
    • 1986
  • Gas sensing materials for detecting inflammable gas such as alcohol, propane, acetic acid, carbon monoxide, hydrogen were developed by utiliting $MgO-Cr_2O_3-TiO_2$ system. Between 30$0^{\circ}C$ and 50$0^{\circ}C$, reversible chemisorption becomes dominant and the electrical canduction of P-type semiconductive with the gas chemisorption. The ceramic sensor exhibits a high sensitivity to particular reducing gas such as alcohol, whereas propane and butane have little effect on the resistivity. The time response of adsorption is estimated to be about 20 sec. On the other hand, the desorption process, which corresponds to oxidation due to oxygen adsorption, take more than 60 sec. Thus the ceramic sensor can be used as a alcohol sensor in an ambient aunosphere. As the oxygen concentration is increased from 0.1 to 10 precent($10^3-10^6ppm$), the resistance decreases rapidly but stabilizes at higher concentration.

  • PDF

Mechanical Properties and Microstructure of Aluminum Alloys with Dispersed Nanoscale Quasicrystalline Particles

  • Fujita, Masashi;Kimura, Hisamichi;Inoue, Akihisa
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.708-709
    • /
    • 2006
  • New Al-based alloys with very high ultimate tensile strength were developed in high Al concentration range of 91-95 at.% for Al-Fe-Cr-Ti-M (M: Co and Mo) systems and Al-Fe-Cr-Mo-Ti-Co system by the dispersion of nanoscale quasicrystalline particles in Al phase. The effect of adding elements, M was discussed in the viewpoint of stability of super-cooled liquid state and formation ability of quasicrystalline phase. The P/M Al-Fe-Cr-Ti-M alloys with dispersed nanoscale quasicrystalline particles exhibited ultimate tensile strength of 350MPa at 573K and 200MPa at 673K.

  • PDF

MPE-LPC를 이용한 심전도 신호의 압축 (Compression of Electrocardiogram Using MPE-LPC)

  • 이태진;김원기;차일환;윤대희
    • 전자공학회논문지B
    • /
    • 제28B권11호
    • /
    • pp.866-875
    • /
    • 1991
  • In this paper, multi pulse excited-linear predictive coding (MPE-LPC), where the correlation eliminated residual signal is modeled by a few pules, is shown to be effective for the compression of electrocardiogram (ECG) data, and a more efficient scheme for a faithful reconstruction of ECG is proposed. The reconstruction charateristic of QRS's and P.T waves is improved using the adaptive pulse allocation (APA), and the compression ratio (CR) can be changed by controlling the mumber of modeling pulses. The performance of the proposed method was evaluated using 10 normal and 10 abnormal ECG data. The proposed method had a better performance than the variable threshold amplitude zone time epoch coding (AZTEC) algorithm and the scan-along polygonal approximation (SAPA) algorithm with the same CR. With the CR in kthe range of 8:1 to 14:1, we could compress ECG data efficiently.

  • PDF

전기화학적 분극특성을 이용한 2.25Cr-lMo 강의 열화도 평가 (The Evaluation of 2-25Cr-lMo Steels Degradation by the Electrochemical Polarization Method)

  • 김지수;현양기;이재도;오세규
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.314-319
    • /
    • 2001
  • Most parts of facilities in domestic petroleum plants and power plants are needed to be abandoned, repaired or replaced, because in Korea they were built in the 1960s and, they have been used under severe conditions and exposed corrosive environments. 2.25Cr- lMo steels have excellent high-temperature mechanical properties. Therefore, the material have been widely used as heat exchanger tubes, boiler headers and its tubes in such industries. But, those microstructural evolutions in high temperature such as precipitation and carbide coarsening give a reason to degrade the material. Especially, in case of this material, carbides induced embrittlement(CIE) is the primary reason for degrading mechanical properties at over 50$0^{\circ}C$. In this paper, we introduce a electrochemical polarization method for detecting CIE quantitatively.

  • PDF