• Title/Summary/Keyword: p-k Method

Search Result 15,972, Processing Time 0.059 seconds

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

Combining Independent Permutation p Values Associated with Mann-Whitney Test Data

  • Um, Yonghwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.99-104
    • /
    • 2018
  • In this paper, we compare Fisher's continuous method with an exact discrete analog of Fisher's continuous method from permutation tests for combining p values. The discrete analog of Fisher's continuous method is known to be adequate for combining independent p values from discrete probability distributions. Also permutation tests are widely used as alternatives to conventional parametric tests since these tests are distribution-free, and yield discrete probability distributions and exact p values. In this paper, we obtain permutation p values from discrete probability distributions using Mann-Whitney test data sets (real data and hypothetical data) and combine p values by the exact discrete analog of Fisher's continuous method.

Determination of Parathion Metabolite, p-Nitrophenol in Urine of Parathion Factory Workers

  • Han, Don-Hee;Jung, Dong-Gyun;Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.985-987
    • /
    • 2008
  • Parathion is an organophosphate pesticide being legally applied for the purpose of agriculture and is being manufactured in Korea. A gas chromatography/mass spectrometric method was developed for the determination of parathion urinary metabolite, p-nitrophenol. p-Nitrophenol was extracted from weak acidic urine, and then measured by gas chromatography-mass spectrometry (selected ion monitoring). The recovery of pnitrophenol in the overall procedure was 88.2%. The detection limit of the assay was 1.0 $\mu$ g/L based upon assayed urine of 2.0 mL. The method was applied to the determination of p-nitrophenol in urine of workers of a parathion industry. Spot urines of workers of a parathion industry were sampled at the end of shift and pnitrophenol was analyzed using above developed method. p-Nitrophenol could be detected in all of the urine samples at concentrations varying from 3.0 to 681 $\mu$ g/L.

Syntheses and Optical Properties of Cholesteric Liquid Crystal Polymers Utilizing p-Phenylene Bis-(p-(3-acryloxy-2-methylpropyloxy)benzoate

  • Yoon, Ung-Chan;Choi, Jung-Hei;Jin, Sung-Ho;Song, Dong-Mi
    • Journal of Photoscience
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • We synthesized chiral choleseric liquid crystalline monomer p-phenylene bis-(p-3-acryloxy-2(S)-methylpropoxy)benzoate (1) and achiral nematic liquid crystalline monomer, p-phenylene p-acryloxy-6-hexyloxy-p-octyloxybenzoate (2) for the construction of cholesteric polymer network with a pitch gradient. In this research we attempted to synthesize cholesteric polymer film which have a wide reflection bandwidth in the region of visible wavelength with the synthesized chiral cholesteric monomer 1 and nematic monomer 2 under various photopoly merization conditions. We succeeded to construct cholesteric polymer film network with a pitch gradient covering more than 200 nm bandwidth in the visible wavelength by diffusion controlled photostructuring method.

  • PDF

MPPT Control Method comparison of the Stand-alone PV system (독립형 태양광 발전시스템의 MPPT 제어기법 비교)

  • Lee, Yong-Sik;Kim, Nam-In;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1386-1387
    • /
    • 2011
  • Maximum power point tracking(MPPT) techniques are used in photovoltaic systems to maximize the PV array output power by tracking continuously the maximum power point which depends on panels temperature and on irradiance conditions. In this paper, the controller of the stand-alone PV system applicable to various fields are designed. The improved P&O MPPT and traditional P&O MPPT method was applied. This improved algorithm consists of a constant perturbation with an step control which will make easier the controller PV power data acquisition process. This strategy of control has, in first time, been validated by PSIM simulations. After, been field test. The experimental results show that the improved P&O method increased the PV output power compare to traditional P&O method.

  • PDF

Complexity Control Method of Chaos Dynamics in Recurrent Neural Networks

  • Sakai, Masao;Honma, Noriyasu;Abe, Kenichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.494-494
    • /
    • 2000
  • This paper demonstrates that the largest Lyapunov exponent $\lambda$ of recurrent neural networks can be controlled by a gradient method. The method minimizes a square error $e_{\lambda}=(\lambda-\lambda^{obj})^2$ where $\lambda^{obj}$ is desired exponent. The $\lambda$ can be given as a function of the network parameters P such as connection weights and thresholds of neurons' activation. Then changes of parameters to minimize the error are given by calculating their gradients $\partial\lambda/\partialP$. In a previous paper, we derived a control method of $\lambda$via a direct calculation of $\partial\lambda/\partialP$ with a gradient collection through time. This method however is computationally expensive for large-scale recurrent networks and the control is unstable for recurrent networks with chaotic dynamics. Our new method proposed in this paper is based on a stochastic relation between the complexity $\lambda$ and parameters P of the networks configuration under a restriction. Then the new method allows us to approximate the gradient collection in a fashion without time evolution. This approximation requires only $O(N^2)$ run time while our previous method needs $O(N^{5}T)$ run time for networks with N neurons and T evolution. Simulation results show that the new method can realize a "stable" control for larege-scale networks with chaotic dynamics.

  • PDF

Kinetic Modeling for Quality Prediction During Kimchi Fermentation

  • Chung, Hae-Kyung;Yeo, Kyung-Mok;Kim, Nyung-Hwan
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1996
  • This study was conducted to develop the fermentation kinetic model for the prediction of acidity and pH changes in Kimchi as a function of fermentation temperatures. The fitness of the model was evaluated using traditional two-step method and an alternative non-linear regression method. The changes in acidity and pH during fermentation followed the pattern of the first order reaction of a two-step method. As the fermentation temperature increased from 4$^{\circ}C$ to 28, the reaction rates of acidity and pH were increased 8.4 and 7.6 times, respectively. The activation energies of acidity and pH were 16.125 and 16.003kcal/mole. The average activation energies of acidity and pH using a non-linear method were 16.006 by the first order and 15.813 kcal/mole by the zero order, respectively. The non-linear procedure had better fitting 개 experimental data of the acidity and pH than two-step method. The shelf-lives based on the time to reach the 1.0% of acidity were 33.1day at 4$^{\circ}C$ and 2.8 day 28$^{\circ}C$.

  • PDF

Comparison of the [$^2H_5$]Phenylalanine Model with the [1-$^{13}C$]Leucine Method to Determine Whole Body Protein Synthesis and Degradation in Sheep Fed at Two Levels

  • Al-Mamun, M.;Ito, C.;Fujita, T.;Sano, H.;Sato, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.10
    • /
    • pp.1517-1524
    • /
    • 2007
  • The [$^2H_5$]phenylalanine model was compared with the [1-$^{13}C$]leucine method to determine whole body protein synthesis (WBPS) and degradation (WBPD) in sheep fed at two levels. The animals were fed either 103 (M-diet) or 151 (H-diet) kcal $ME/kg^{0.75}/day$ once daily in a crossover design for 21 days each. The isotope dilutions were simultaneously conducted as a primed-continuous infusion of [$^2H_5$]phenylalanine, [$^2H_2$]tyrosine and [1-$^{13}C$]leucine on each dietary treatment. The WBPS and WBPD calculated from the [$^2H_5$]phenylalanine model were lower (p = 0.009 and p = 0.003, respectively) than those calculated from the [1-$^{13}C$]leucine method. The WBPS tended to be higher (p = 0.08) and WBPD was numerically higher (p = 0.33) for H-diet than M-diet in the [$^2H_5$]phenylalanine model, whereas the WBPS was numerically higher (p = 0.37) for H-diet and WBPS remained similar (p = 0.79) between diets in the [1-$^{13}C$]leucine method. However, the absolute values and the directions of WBPS as well as WBPD from M-diet to H-diet were comparable between the [$^2H_5$]phenylalanine model and [1-$^{13}C$]leucine method. Moreover, the values vary depending on the use of the respective amino acid contents in the carcass protein when calculating WBPS and WBPD. Therefore, it is concluded that the [$^2H_5$]phenylalanine model could be used as an alternative to the [1-$^{13}C$]leucine method for the determination of WBPS and WBPD in sheep.