• Title/Summary/Keyword: p-Moments

Search Result 175, Processing Time 0.019 seconds

Optimization of parasitic inductance for maximizing the modulation bandwidth of MQW modulators (MQW 광변조기의 변조대역폭 확대를 위한 실장 기생 인덕턴스의 최적화)

  • 김병남;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.20-32
    • /
    • 1997
  • An optimum parasitic inductance is observed for maximizing the modulation bandwidth of the multiple quantum well (MQW) electro-absorption optical modulator. For 1.1 pF device cpaacitance of the current MQW optical modulator, the optimum parasitic inductances for maximum bandwidth are calculated for different terminating resistors. In ase of 50.ohm. terminating resistor, the 3-dB modulation bandwidth can be increased 45% wider by using the optimum parasitic inductance than nothing parasitic inductance. This calculated optimum inductance can be practically implemented, since the parasitic inductance of bondwires can be accurately analyzed using the method of moments (MoM) and controlled by changing the length and shpae of bondwires.

  • PDF

Closed form solutions for element equilibrium and flexibility matrices of eight node rectangular plate bending element using integrated force method

  • Dhananjaya, H.R.;Pandey, P.C.;Nagabhushanam, J.;Othamon, Ismail
    • Structural Engineering and Mechanics
    • /
    • v.40 no.1
    • /
    • pp.121-148
    • /
    • 2011
  • Closed form solutions for equilibrium and flexibility matrices of the Mindlin-Reissner theory based eight-node rectangular plate bending element (MRP8) using Integrated Force Method (IFM) are presented in this paper. Though these closed form solutions of equilibrium and flexibility matrices are applicable to plate bending problems with square/rectangular boundaries, they reduce the computational time significantly and give more exact solutions. Presented closed form solutions are validated by solving large number of standard square/rectangular plate bending benchmark problems for deflections and moments and the results are compared with those of similar displacement-based eight-node quadrilateral plate bending elements available in the literature. The results are also compared with the exact solutions.

GMM을 이용한 자본자산가격결정모형(資本資産價格決定模型)의 추정(推定)

  • Lee, Ju-Hui;Nam, Ju-Ha
    • The Korean Journal of Financial Management
    • /
    • v.9 no.2
    • /
    • pp.57-75
    • /
    • 1992
  • 본 논문은 10개의 기업규모별 자산을 대상으로 최근에 발전된 계량기법인 GMM(generalized method of moments)을 이용하여 베타(beta)를 추정하였다. 분석대상기간으로 $1982.1{\sim}1991.4$사이의 월별자료를 사용한다. 실증분석 결과에 의하면, 기업규모별 구분에 따른 자산의 경우에 규모가 큰 기업보다 규모가 작은 기업의 베타가 상대적으로 작은 것으로 나타났다. GMM의 추정을 위한 수단변수로 회사채수익률과 정기예금금리의 금리차, 분석대상이 되는 자산 수익률과 시장포트폴리오의 자기시차, 그리고 상수가 사용되었다. OLS를 사용한 CAPM추정 결과에 비해 GMM을 사용한 추정 결과가 우월할 수 있음을 보여주고 있는데, 이것은 GMM에 사용된 수단변수들이 수단변수를 포함시킴으로써 관련자산들의 자기시차가 아닌 CAPM추정에 필요한 유용한 대용변수(代用變數)(proxy)를 제공하였고, 나아가 GMM이 잔차항(殘差項)의 자기상관(自己相關) 뿐만 아니라 조건부(條件附) 이분산(異分散)(conditional heteroskedasticity)을 잘 설명하고 있기 때문인 것으로 판단된다. t값 및 P-value에 의하면 GMM을 사용한 단순 CAPM 추정이 우리 나라의 현실경제와 잘 부합될 수 있음을 암시한다.

  • PDF

기포탑반응기에서 가스 SENSOR 재료인 PZT 분말의 합성(I)

  • 현성호;김정환
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.40-51
    • /
    • 1996
  • A synthesis process for PZT powder using NH$_3$ gas as a precipitator in a bubble column reactor was experimentally successful in develope a production process of Piezoelectric ceramic PZT powder. Also as a reaction by coprecipitation, the crystalized PZT ceramic powder at the condition of over pH 9 could be attained. The time needed for reaction on the condition of NH$_3$ gas flow rate=0.5 1/min, Ar gas flow rate=2.0 1/min, Feed flow rate=2.33 ml /sec was less than five minutes, so it could synthesize PZT powder for such a few moments. And the synthesized PZT powder was 0.17${\mu}{\textrm}{m}$ in diameter on an average.

  • PDF

Characterization of Spinel Lithium Manganite Prepared by Citrate Sol-Gel Method

  • 홍영식;박휴범;이지은;한치환;김시중
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.11
    • /
    • pp.1153-1158
    • /
    • 1997
  • The powder characteristics of LiMn2O4 prepared by the citrate sol-gel method have been investigated. The optimum pH for the preparation of homogeneous citrate gel was calculated by the theoretical consideration of thermodynamic equilibrium constants for metal-citrate complexes and metal salts. The obtained citrate gel was prefired at 300 ℃ and calcined at 300-700 ℃ for 1 h. The obtained powders were characterized by TG/DSC, FT-IR spectrometer, X-ray diffractometer, SQUID magnetometer, SEM, and particle size analyzer. It was observed that the mixed phases of spinel LiMn2O4 and Mn3O4 were transformed into spinel LiMn2O4 phase and the vibrational bands due to the carbonate and nitrate were also disappeared over 400 ℃. At temperatures below 150 K, inverse molar susceptibilities of every sample began to show an antiferromagnetic ordering of Mn magnetic moments.

Depth Control of Autonomous Underwater Vehicle Using Robust Tracking Control (강인추적 제어를 이용한 자율 무인 잠수정의 심도제어)

  • Chai, Chang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.66-72
    • /
    • 2021
  • Since the behavior of an autonomous underwater vehicle (AUV) is influenced by disturbances and moments that are not accurately known, the depth control law of AUVs must have the ability to track the input signal and to reject disturbances simultaneously. Here, we proposed robust tracking control for controlling the depth of an AUV. An augmented closed-loop system is represented by an error dynamic equation, and we can easily show the asymptotic stability of the overall system by using a Lyapunov function. The robust tracking controller is consisted of the internal model of the command signal and a state feedback controller, and it has the ability to track the input signal and reject disturbances. The closed-loop control system is robust to parameter uncertainties. Simulation results showed the control performance of the robust tracking controller to be better than that of a P + PD controller.

Effects of the Flex-OA Functional Shoe and the Standardized Shoe on Ranges of Hip and Knee Joint During Gait in Healthy Individuals (정상 성인에서 Flex-OA 기능성 신발과 일반 신발이 보행 중 엉덩관절과 무릎관절의 가동범위에 미치는 효과)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the characteristics of the Flex-OA shoe, a specific functional shoe, in terms of the range of motion (ROM) of hip and knee joint during walking when compared to a standardized shoe. Methods : Twenty-six healthy adults (18 males, 6 females) participated in this study. Subjects performed 8 walking trials consisting of two different shoe conditions to evaluate the hip and knee ROM using a three-dimensional motion capture system. Visual 3D motion analysis software was finally used to coordinate the kinematic data. Result : The total ROM and maximal abduction range of the hip joint in the coronal planes when wearing the Flex-OA shoe were significantly increased during walking compared to wearing a standard shoe (p<.05). On the other hand, significantly increased ROM was observed in the sagittal plane when wearing the Flex-OA shoe in the knee joints compared to a standard shoe (p<.05). Conclusion : Although clinical application of the specific functional shoe has known clearly positive effects on knee moments, the results of this study could provide important clues to explain the background of these effects in terms of the hip and knee joints when applying a specific functional shoe.

Effects of Functional Footwear Designed for Decreasing Ground Reaction Force on Ankle and Foot Range of Motion During Gait in Healthy Individuals

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.113-120
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the characteristics of a specific functional shoe in terms of the range of motion (ROM) of ankle and foot joints during walking when compared to a standardized shoe. METHODS: Kinematic ROM data pertaining to ankle, tarsometatarsal, and metatarsophalangeal joints were collected from twenty-six healthy individuals during walking using a ten-camera motion analysis system. Kinematic ROM of each joint in three planes was obtained over ten walking trials consisting of two different shoe conditions. Visual3D motion analysis was finally used to coordinate the kinematic data. All kinematic ROM data were interpolated using a cubic spline algorithm and low-pass filtered with a cutoff frequency of 6 Hz for smoothing. RESULTS: The overall ROM of the ankle joint in the sagittal and coronal planes when wearing the specific functional shoe was significantly decreased in both ankles during walking when compared to wearing a standard shoe (p<.05). Significantly more flexibility was observed when wearing the specific functional shoe in the tarsometatarsal and metatarsophalangeal joints compared to a standard shoe (p<.05). CONCLUSION: Although clinical application of the specific functional shoe has shown clear positive effects on knee and ankle moments, the results of this study provide important background information regarding the kinematic mechanisms of these effects.

Load carrying capacity of deteriorated reinforced concrete columns

  • Tapan, Mucip;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • v.6 no.6
    • /
    • pp.473-490
    • /
    • 2009
  • This paper presents a new methodology to evaluate the load carrying capacity of deteriorated non-slender concrete bridge pier columns by construction of the full P-M interaction diagrams. The proposed method incorporates the actual material properties of deteriorated columns, and accounts for amount of corrosion and exposed corroded bar length, concrete loss, loss of concrete confinement and strength due to stirrup deterioration, bond failure, and type of stresses in the corroded reinforcement. The developed structural model and the damaged material models are integrated in a spreadsheet for evaluating the load carrying capacity for different deterioration stages and/or corrosion amounts. Available experimental and analytical data for the effects of corrosion on short columns subject to axial loads combined with moments (eccentricity induced) are used to verify the accuracy of proposed model. It was observed that, for the limited available experimental data, the proposed model is conservative and is capable of predicting the load carrying capacity of deteriorated reinforced concrete columns with reasonable accuracy. The proposed analytical method will improve the understanding of effects of deterioration on structural members, and allow engineers to qualitatively assess load carrying capacity of deteriorated reinforced concrete bridge pier columns.

A Study on Determination for Location of Localizer Antenna under Area Restrictive Conditions at Domestic P-Airport (국내 P공항의 부지 제한조건을 고려한 로컬라이저의 최적위치 선정에 관한 연구)

  • Cho, Hwan-Kee;Kim, Jong-Bum;Song, Byung-Heum
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.7-14
    • /
    • 2015
  • This paper deals with an optimal determination process for the built-in location of localizer under restrictive siting area conditions of a domestic P-airport. Aerodynamic forces and moments acting on the localizer structure can be used a reference to find the safe distance from jet blast and the position at which the reasonable structural loading is applied. Wind tunnel experiment is conducted to measure aerodynamic loadings. The finite element analysis for structural deformation is employed to get the information of structural failure. A new localizer's position is determined by considering aerodynamic loading, structural strength and thermal loading due to jet blast. Deflector effect was also investigated in this study. In conclusion, the location of localizer can be placed at shorter than the current position and greatly decreased if the deflector is applied at the front of localizer.