• Title/Summary/Keyword: p-값

Search Result 7,792, Processing Time 0.033 seconds

Implementing Range Queries in Structured P2P Systems using Tree-Structure (Structured P2P에서 트리 구조를 이용한 Range Query의 구현)

  • 박성진;권오훈;김종
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.46-48
    • /
    • 2004
  • Distributed Hash Table(DHT)를 기반으로 하는 structured P2P에서 복잡 질의를 통친 원하는 자료를 찾는 것은 쉽지 않다. 이와 같은 것들 중 하나가 범위 값을 이용하여 원하는 값을 찾는 range query이다. 본 논문에서는 full binary tree의 특징을 이용하여 structured P2P에서 range query를 수행할 수 있는 mapping 함수와, load balance를 지원하기 위한 방법을 제안한다 또한 실험을 통해서 이 방법들이 어느 정도의 성능을 보여주는 지도 살펴본다.

  • PDF

Cross-Correlation Distribution of a p-ary m-Sequence Family Constructed by Decimation (Decimation에 의해 생성된 p-진 m-시퀀스 군의 상호 상관 값의 분포)

  • Seo, Eun-Young;Kim, Young-Sik;No, Jong-Seon;Shin, Dong-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9C
    • /
    • pp.669-675
    • /
    • 2008
  • For an odd prime p, n=4k and $d=((p^2k+1)/2)^2$, there are $(p^{2k}+1)/2$ distinct decimated sequences, s(dt+1), $0{\leq}l<(p^{2k}+1)/2$, of a p-ary m-sequence, s(t) of period $p^n-1$. In this paper, it is shown that the cross-correlation function between s(t) and s(dt+l) takes the values in $\{-1,-1{\pm}\sqrt{p^n},-1+2\sqrt{p^n}\}$ and their, cross-correlation distribution is also derived.

Effect of Dietary Rhus verniciflua Stokes on the Quality of Hanwoo (Korean Cattle) Beef during Cold Storage after Thawing (옻 급여가 한우육의 해동후 냉장중 품질에 미치는 영향)

  • Liang Cheng-Yun;Kang Sun-Moon;Kim Yong Sun;Lee Sung Ki
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.196-202
    • /
    • 2005
  • This study was carried out to investigate the effect of dietary Rhus verniciflua Stokes on the quality of Hanwoo (Korean cattle) beef during cold storage $(4^{\circ}C)$ after thawing. After 4 groups (3 heads/group) of 22 months-Hanwoo (Korean cattle) steen were fed a common basal diet with 0, 2, 4 and $6\%$ Rhus verniciflua Stokes (RVS) powder for 4 months prior to slaughter, samples of M semimembranous from 12 carcasses were stored at $-20^{\circ}C$ for 9 months. Crude fat was significantly lower in 4 and $6\%$ RVS treatments than in control (p<0.05). pH value was significantly higher in4 and $6\%$ RVS treatments than in control from 2 and 5 days (p<0.05). Thawing loss was not significantly different among the treatments but drip loss was significantly lower in 4 and $6\%$ RVS treatments than in control during storage (p<0.05). CIE $L^{\ast}$ value was significantly lower in RVS treatments than in control during storage (p<0.05) and CIE $a^{\ast}$ value was significantly higher in 4 and $6\%$ RVS treatments than in control (p<0..05). CIE $b^{\ast}$ value was significantly higher in control than in $6\%$ RVS treatment in 0 days (p<0.05) but it was significantly higher in $4\%$ RVS treatment than in control in 7 days (p<0.05). CIE $C^{\ast}$ value was significantly higher in $4\%$ RVS treatment than in control during storage (p<0.05) and CIE $h^0$ value was significantly lower in $4\%$ RVS treatment than in control (p<0.05). TBARS value of 2 days was significantly lower in 4 and $6\%$ RVS treatments than in control (p<0.05) but it was significantly lower in $4\%$ RVS treatment than the other treatments from 5 days (p<0.05). Surface MetMb concentration was significantly lower in RVS treatment than in control during storage (p<0.05) and it was significantly lower in $4\%$ RVS treatment than in the other treatments in 7days (p<0.05) but surface $R_{6.30}/R_{580}$ value was opposite to this result.

Blood Pressure and Serum Lipids in Relation to Serum Gamma-glutamyltransferase Activity in Men of Rural Area (농촌 지역 남성들에서 혈청 Gamma-glutamyltransferase 활성도와 혈압 및 혈청 지질의 관련성)

  • Oh, Myoung-Joo;Cho, Byung-Mann;Hwang, In-Kyung;Lee, Sang-Don;Chung, Moon-Kee
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.2
    • /
    • pp.123-133
    • /
    • 2003
  • Objectives: To examine the association between serum gamma-glutamyltransferase(GGT) activity level and blood pressure, serum lipids in the male residents of rural area, we analyzed cross-sectionally the data of 379 male health examinees aged 40 years and older from rural areas in Gyeongsangnam-do prefecture in Korea. Methods: Blood pressure and concentration of serum lipids were compared between high and low level of serum GGT activity by t-test or Wilcoxon rank sum test. Possible confounding effects of age, body mass index and coffee drinking were adjusted by analysis of covariance. Results: Adjusted values of systolic and diastolic blood pressure were higher in the group of high level of serum GGT activity in non-drinkers(P=0.055 and P=0.074 respectively) and drinkers(P=0.284 and P=0.398) of alcohol. Adjusted serum total cholesterol level was also higher in the group of high level of serum GGT activity in non-drinkers(P=0.052) but not in drinkers(P=0.981) of alcohol. In serum triglyceride, adjusted level was significantly higher in the group of high level of serum GGT activity in both non-drinkers(P=0.035) and drinkers(P=0.002) of alcohol. Conclusions: These results suggest the association of serum GGT activity and serum triglyceride, total cholesterol, or blood pressure in non-drinkres of alcohol.

  • PDF

Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study (내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구)

  • Lee, Sang-Woon;Cha, Min-Sang;Lee, Ji-Hye;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.95-103
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials and Methods: Internal conical connection implants were divided into two groups (n = 10): group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. Results: HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). Conclusion: Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque.

Detorque Values of Various Compatible Dental Implant Screws (호환 가능한 수종의 치과용 임플란트 나사의 풀림토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • This study evaluated the effect of 3 different compatible screws on the detorque values in a multiple implant-supported superstructure and single implant abutments. An implant superstructure directly connected to 4 implants was screwed to 6 experimental dental stone casts made by acrylic resin splinted impressions, using 20 Ncm. The detorque values of screws were measured twice. Three compatible abutment screws used in this study were TorqTite screw, Gold-Tite screw, and, Titanium screw. And, using single implant abutments (GoldAdapt Engaging abutments), the detorque values of 3 different screws were measured twice on 2 implants of 5 experimental casts. According to statistical analysis of detorque values using mixed model at a .05 level of significance, no statistically significant differences among 3 different compatible screws were found in a multiple implant-supported superstructure (p>0.05). But, in single implant abutments, statistically significant differences among 3 different compatible screws were found (p=0.0175). The detorque values of TorqTite(p=0.0462) and Titanium(p=0.0348) screws were significantly higher than those of Gold-Tite screw, but no statisticantly significantlydifferences were found between TorqTite and Titanium screws(p>0.05). Therefore, various compatible screws showed significant effects on the detorque values for single implant abutment, but, showed no significant effects for a multiple implant-supported superstructure.

Correlation of the Speed of Enhancement of Hepatic Hemangiomas with Intravoxel Incoherent Motion MR Imaging (간혈관종의 조영증강속도와 복셀내비결집운동 MR영상과의 상관관계)

  • Yang, Dal Mo;Jahng, Geon-Ho;Kim, Hyun Cheol;Kim, Sang Won;Kim, Hyug-Gi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.208-218
    • /
    • 2014
  • Purpose : To evaluate the relationship between the speed of enhancement of hepatic hemangiomas on gadolinium-enhanced MRI and ADC values by using various parameters, including the D, f, $D^*$ and $ADC_{fit}$ on intravoxel incoherent motion (IVIM) MR Imaging. Materials and Methods: The institutional review board approved this retrospective study. A total of 47 hepatic hemangiomas from 39 patients were included (20 men and 19 women). The hemangiomas were classified into three types according to the enhancement speed of the hepatic hemangiomas on gadolinium-enhanced dynamic T1-weighted images: rapid (Type A), intermediate (Type B), and slow (Type C) enhancement. The D, f, $D^*$ and $ADC_{fit}$ values were calculated using IVIM MR imaging. The diffusion/perfusion parameters and ADC values were compared among the three types of hemangiomas. Results: Both the $ADC_{fit}$ and D values of type C were significantly lower than those of type A (P = 0.0022, P = 0.0085). However, for the f and $D^*$, there were no significant differences among the three types. On DWI with all b values (50, 200, 500 and $800sec/mm^2$), the ADC values of type C were significantly lower than those of the type A (P < 0.012). For b values with $800sec/mm^2$, the $ADC_{800}$ values of the type C hemangiomas were significantly lower than those of type B (P = 0.0021). We found a negative correlation between hepatic hemangioma enhancement type and $ADC_{50}$ (${\rho}=-0.357$, P = 0.014), $ADC_{200}$ (${\rho}=-0.537$, P = 0.0001), $ADC_{500}$ (${\rho}=-0.614$, P = 0.0001), and $ADC_{800}$ (${\rho}=-0.607$, P = 0.0001). Therefore, four ADC values of $ADC_{50}$, $ADC_{200}$, $ADC_{500}$, and $ADC_{800}$ were decreased with decreasing enhancement speed. Conclusion: Hepatic hemangiomas had variable ADCs according to the type of enhancement, and the reduced ADCs in slowly enhancing hemangiomas may be related to the reduced pure molecular diffusion (D).

Analysis of Liver Elasticity according to Ultrasound Findings (초음파 소견에 따른 간 탄성도 분석)

  • Chun, Hye-Ri;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • This study was conducted on 101 patients who visited hospital for abdominal ultrasonography from May 2020 to December 2020. The purpose of this study was to find out the elasticity according to the ultrasound images (echo pattern, splenomegaly, hepatitis) during the ultrasound examination using the shear wave elastography. The shear wave elastography value of the normal group of the echo pattern was 5.75±1.58 kPa, and the group with the abnormal echo pattern was 8.84±4.94 kPa, and the shear wave elastography value of the abnormal group was high (p<0.05). In normal spleen size, hepatic elasticity value was 6.33±2.54 kPa, and hepatic elasticity value of splenomegaly was 13.73±5.48 kPa. In the case of splenomegaly, the liver elasticity value was high, and there was a statistically significant difference (p<0.05). As the spleen size increased, the liver elasticity value increased by 1.485 times, and as hepatitis progressed, the liver elasticity value increased by 1.573 times (p<0.05). As a result of analysis of concordance between ultrasound imaging findings and shear wave elastography, the Kappa value was found to be as high as 0.922 (p<0.05), which showed high concordance between the two test methods. Additional comparisons of liver elasticity values in shearwave elastography tests along with liver ultrasound findings are thought to be of great help in diagnosing liver fibrosis.

A Study on the Electrometric Measurement of the pH of Acid Rain (산성비의 pH 측정에 대한 연구)

  • Lee, Hwa-Shim;Kim, Myung-Soo
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.10-16
    • /
    • 2000
  • In general, acid rain is unbuffered solution with low ionic strength and high resistance. Therefore during the pH measurement of acid rain, error can be occurred due to the liquid junction potential difference between the sample and the standard solution. Actually the average conductivity of rain in Taeduk Science Town during 1998 is 12.8 ${\mu}S/cm$, while that of pH standmd solutions is about 5,980 ${\mu}S/cm$. There is a large difference in ionic strength. To compensate the bias due to residual liquid junction potentials, a quality control standard(QCS) of dilute sulfuric acid, which has the conductivity and pH values simikw to rain, was prepared. The pH of QCS solution was determined using the hydrogen electrode system without liquid junction, and compensation has been made for the bias terms by performing the pH measurements with glass electrode. On the basis of this compensation method, the pH vaiues of rain in Taeduk Science Town during 1998 were measured.

  • PDF

Evaluation of Low or High Permeability of Fractured Rock using Well Head Losses from Step-Drawdown Tests (단계양수시험으로부터 우물수두손실 항을 이용한 단열의 고.저 투수성 평가)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Kim, Geon-Young;Koh, Yong-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The equation of the step-drawdown test "$s_w=BQ+CQ^p$" written by Rorabaugh (1953) is suitable for drawdown increased non-linearly in the fractured rocks. It was found that value of root mean square error (RMSE) between observed and calculated drawdowns was very low. The calculated $C$ (well head loss coefficient) and $P$ (well head loss exponent) value of well head losses ($CQ^p$) ranged $3.689{\times}10^{-19}{\sim}5.825{\times}10^{-7}$ and 3.459~8.290, respectively. It appeared that the deeper depth in pumping well the larger drawdowns due to pumping rate increase. The well head loss in the fractured rocks, unlike that in porous media, is affected by properties of fractures (fractures of aperture, spacing, and connection) around pumping well. The $C$ and $P$ value in the well head loss is very important to interpret turbulence interval and properties of high or low permeability of fractured rock. As a result, regression analysis of $C$ and $P$ value in the well head losses identified the relationship of turbulence interval and hydraulic properties. The relationship between $C$ and $P$ value turned out very useful to interpret hydraulic properties of the fractured rocks.