• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.024 seconds

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.

The UV/Ozone Stability of PET and Nylon 6 Nanocomposite Films Containing TiO2 Photocatalysts (TiO2 광촉매를 함유한 PET와 나일론 6 나노복합체막의 자외선/오존에 대한 안정성)

  • Jin, Sung-Woo;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.26 no.2
    • /
    • pp.88-98
    • /
    • 2014
  • This study is to assess the photocatalytic degradation of PET and Nylon 6 films containing nano-sized $TiO_2$ powders of anatase and rutile types. The PET and Nylon 6 films containing six kinds of the nanoparticles were prepared by melt casting method using a heating press machine. Reflectance in visible region and water contact angles of the irradiated PET and Nylon 6 composite films decreased with increasing UV/$O_3$ irradiation. Also the enhanced hydrophilicity has a close relationship with the increase in the Lewis base parameter, which indicates more oxidized polymer surfaces. The photocatalytic degradation of the nanocomposite films increased with increasing $TiO_2$ content and UV energy, which is more significant with the anatase types rather than the rutile types. The amide linkages in the Nylon 6 seemed to be more susceptible to the UV light compared to the ester groups in the PET, particularly in the presence of the $TiO_2$ photocatalysts. The photoscission and photodegradation of the polymers in the composites produced more degraded structure assisted by the photocatalytic activity of the $TiO_2$ nanoparticles. Also the composite films can bleach the methylene blue dyes more easily under the UV/$O_3$ irradiation, suggesting the photobleaching activity of the $TiO_2$ nanoparticles.

Solar Radiation Measurement and Analysis of a High Mountain Area (고산지대의 일사량 특성분석 - 소백산과 그 인접 저지대를 중심으로 -)

  • Jo, Dok-Ki;Lee, Tae-Kyu;Chun, Il-Soo;Jeon, Hong-Seok;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.49-63
    • /
    • 1996
  • Site elavation is one of the major factors which is influencing the incoming insolation. Because nonpermanent gases like ozone, water vapor are unmixed components of the atmosphere and their concentrations are function of height, the site elevation effects the relative proportion of the atmospheric constituents. We have measured solar radiation on Sobaek(1,350m) and in Poonggi area(280m). These values were compared to investigate the their charateristics and the potential for the solar utilization as an alternative energy for both high altitude area and low altitude area. From the results, we conclude that 1) Yearly mean 4,093 $kcal/m^2$. day of the horizontal global radiation in Mt. Sobaek was evaluated for clear day. 2) Insolation on Mt. Sobaek is $6{\sim}7%$ higher than Poonggi area during summer and winter seasons. 3) A significant difference of atomospheric clearness index is observed between Mt. Sobaek and Poonggi area at the same latitude.

  • PDF

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

A Study of Closed OTEC Power Plants (폐쇄형 해양온도차발전 사이클에 관한 연구)

  • Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.23-33
    • /
    • 1997
  • In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.

  • PDF

A Study on the Efficient Integration Program between ISO 9000 and ISO 14000 (ISO 9000과 ISO 14000의 효율적인 통합방안에 관한 연구-건설업체 문서체계를 중심으로)

  • 이재훈;강창욱
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.211-218
    • /
    • 1997
  • Since Industrial Revolution, the sudden industrialization and population explosion have brought about a serious environmental pollution on the air of the earth, the quality of water and the soil, and the greenhouse effect by the destruction of the ozone layer and the greenhouse gas, the organism diversity decline, the desertification by the ruining of woods and the overall global environmental pollution such as the contamination of the ocean and rivers have been come to the front. So the new recognition on the environment is being spreaded in construction business and the efforts for certification acquisition of ISO 14000 being followed by ISO 9000 are progressing, Accordingly, with an example of H Company where integration system is built so that it can minimize the efforts and cost at the construction of the management system, operation and management after the fact, this paper shall suggest the practical scheme of 3 steps through a study to integrate both existing quality management system and new environmental management system. As the integration system of the quality and environment which is constructed by this method is executed, the number of the established and managed document is cut by about a third and so the disorder to encounter between these documents is prevented and unnecessary efforts is reduced in constructing a system, consequently the efficiency of the system is accomplished. Also as the dualization of quality management system and environmental management system additionally needs more men and money after certification acquisition, the non-construction of the integration system may give rise to a cause to aggravate the burden of the company and hereafter when a new system is imported, it may be very difficult to integrate the system. This system integration enables a efficient and effective system to be constructed , operated , and managed after the fact.

  • PDF

A Survey on Elementary Students' Perceptions about Global and Local Environmental Issues (초등학생의 전지구적 및 지역적 환경 문제에 대한 인식 조사)

  • Jang, Bo-Ra;So, Keum-Hyun;Shim, Kew-Cheol;Yeau, Sung-Hee
    • Journal of Korean Elementary Science Education
    • /
    • v.28 no.2
    • /
    • pp.142-153
    • /
    • 2009
  • The purpose of this study was to survey primary students' perception of the global and local environmental issues. The subjects were 853 fifth primary students in Seoul, Busan, Daejeon, Anyang, Gimpo and Cheongju. The results were as follows: First, the perception level of the global environmental issues were global warming (M=3.99), drinking-water pollution (M=3.92), acid rain (M=3.77), yellow dust (M=3.66), ozone depletion (M=3.57), deforestation in tropical areas (M=3.52), desertification (M=3.36), biodiversity (M=3.40) and their perception level of local environmental issues were waste disposal (M=3.87), air pollution (M=3.74), bad smell (M=3.70), noise (M=3.61), river pollution (M=3.57), soil pollution (M=3.44). Second, it was shown that the metropolitan students' perception levels of environmental issues were higher than the non-metropolitan students'. There wasn't a significant difference in the perception levels of two scale environmental issues and characteristics for sex (p>.05). Third, the result of analyzing on the effects between characteristics was that the factors like 'environmental interest' and 'impact on personal life' had a strong influence on the 'behavior will' to solve the global environmental issues, and 'environmental interest' and 'personal knowledge' had a strong influence on the 'behavior will' to solve the local environmental issues. Fourth, the result of analyzing on the characteristics according to the types of the environmental issues showed that 'personal knowledge', 'environmental interest' and 'behavior will' were high in the global environmental issues (p<.01) and 'virtual contamination', 'human responsibility' and 'impact on personal life' were high in the local environmental issues (p<.05).

  • PDF

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

A Review on Ceramic Based Membranes for Textile Wastewater Treatment (염색폐수의 처리를 위한 세라믹 분리막에 대한 고찰)

  • Kwak, Yeonsoo;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.100-108
    • /
    • 2022
  • Among various industries, the textile industry uses the largest amount of water for coloring textiles which leads to a large amount of wastewater containing various kinds of dye. There are various methods for the removal of dye such as flocculation, ozone treatment, adsorption, etc. But these processes are not much successful due to the issue of recycling which enhances the cost. Alternatively, the membrane separation process for the treatment of dye in wastewater is already documented as the best available technique. Polymeric membrane and ceramic membrane are two separate groups of separation membranes. Advantages of ceramic membranes include the ease of cleaning, long lifetime, good chemical and thermal resistance, and mechanical stability. Ceramic membranes can be prepared from various sources and natural materials like clay, zeolite, and fly ash are very cheap and easily available. In this review separation of wastewater is classified into mainly three groups: ultrafiltration (UF), microfiltration (MF), and nanofiltration (NF) process.

Adhesive Properties of Epoxy Composite According to the Surface Treatment of Cu Substrate and Adhesion Promoter Content (구리기판의 표면처리 및 접착증진제 함량에 따른 에폭시 컴포지트의 접착특성)

  • Eun-jin Kim;Jung Soo Kim;Young-Wook Chang;Dong Hyun Kim
    • Journal of Adhesion and Interface
    • /
    • v.23 no.4
    • /
    • pp.108-115
    • /
    • 2022
  • In this study, we synthesized poly(itaconic acid-co-acrylamide) (IAcAAM) used as a novel polymer adhesion promoter to improve the adhesion strength of surface-treated Cu lead frames and epoxy composites. IAcAAM comprising itaconic acid, acrylamide was prepared through radical aqueous polymerization. The chemical structure and properties of IAcAAM was analyzed by FT-IR, 1H-NMR, GPC, and DSC. The surface of the copper lead frame was treated with high temperature, alkali, and UV ozone to reduce the water contact angle and increase the surface energy. The adhesive strength of Cu lead frame and epoxy composite increased with the decrease of contact angle. The adhesive strength of Cu lead frame/epoxy composite increased with the addition of IAcAAM in epoxy composite. As silica content increased, the adhesive strength of Cu lead frame and epoxy composite tended to slightly decrease.