• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.542 seconds

전력 및 담수생산을 위한 해양온도차발전에 대한 연구 (Study on OTEC for the Production of Electric Power and Desalinated Water)

  • 박성식;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.124-130
    • /
    • 2010
  • Ocean Thermal Energy Conversion(OTEC) power plants have been examined as a viable option for supplying clean energy. This paper evaluated the thermodynamic performance of the OTEC Power system for the production of electric power and desalinated water. The results show that newly developed fluids such as R32, R125, R143a, and R410A that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. Overall cycle efficiency of open cycle is the lowest value of 3.01% because about 10% of the gross power is used for pumping out non-condensable gas. Also, the hybrid cycle is an attempt to combine the best features and avoid the worst features of the open and closed cycles. The overall cycle efficiency of hybrid cycle is 3.44% and the amount of desalinated water is 0.0619 kg/s.

Radical Mist Generator Using a Water Plasma Jet and Its Sterilization Effect

  • Huh, Jin Young;Ma, Suk Hwal;Kim, Kangil;Choi, Eun Ha;Hong, Yong Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.175.1-175.1
    • /
    • 2016
  • In recent, tract infections such as atopic dermatitis, allergic rhinitis and a respiratory disease are increasing, giving rise to the atmospheric pollution, inflow of micro-size dust and side effect of humidifier disinfectant. In this context, the environment-friendly technology is required to eliminate airborne pathogens. We propose solution of the previous problems, making use of Radical Mist Generator (RMG). Existing technologies of air purification using a gas discharge produce harmful substances such as ozone, NOx, etc. However, the RMG uses a pure water as a plasma forming material. The RMG sprays the water mist, which contains reactive radicals to sterilize microorganisms. RMG is comprised of a power supply, plasma electrodes and a nozzle. In order to analyze the electrical characteristic and concentrations of reactive radicals, we employ an oscilloscope and a titration method. To test the sterilization effect of RMG, we used E.coli. We confirmed that E.coli was killed over 90%. Eventually, we expect that RMG can be promising tool for a purified system.

  • PDF

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

Production of high dissolved O2/O3 with rotating wheel entraining gas method for environmental application

  • Li, Haitao;Xie, Bo;Hui, Mizhou
    • Advances in environmental research
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 2013
  • There is a significant demand to make various dissolved gases in water. However, the conventional aeration method shows low gas mass transfer rate and gas utilization efficiency. In this study, a novel rotating wheel entraining gas method was developed for making high dissolved $O_2$ and $O_3$ in water. It produced higher concentration and higher transfer rate of dissolved $O_2$ and $O_3$ than conventional bubble aeration method, especially almost 100% of gas transfer efficiency was achieved for $O_3$ in enclosed reactor. For application of rotating wheel entraining gas method, aerobic bio-reactor and membrane bio-reactor (MBR) were successfully used for treatment of domestic and pharmaceutical wastewater, respectively; and vacuum ultraviolet $(VUV)/UV+O_3/O_2$ reactors were well used for sterilization in air/water, removal of dust particles and toxic gases in air, and degradation of pesticide residue and sterilization on fruits and vegetables.

감마선 처리를 이용한 고무공장 폐수의 생물독성 저감 (Toxicity Reduction of Wastewater from a Rubber Products Manufacturing Factory by Gamma-ray Treatment)

  • 박은주;조훈제;조기종;김정규;정진호
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.913-918
    • /
    • 2006
  • Both raw wastewater and effluent from a rubber products manufacturing factory were found to be toxic to Daphnia magna though the effluent satisfied current water quality standards. Thus, in order to reduce toxicity, advanced oxidation processes (AOPs) such as gamma-ray (${\gamma}-ray$) treatment and ozonation ($O_3$) were applied. A combined ${\gamma}-rays/O_3$ treatment at 20 kGy after coagulation significantly reduced toxicity of raw wastewater, changing 48-h toxic unit (TU) value from 201.21 to 23.92. However, toxicity of treated water was higher than that of effluent (TU = 12.15). This shows limitation of gamma-ray treatment to remove toxicity of raw wastewater. In case of effluent, the combined ${\gamma}-rays/O_3$ treatment at 20 kGy efficiently decomposed toxic compounds down to non toxic level. This work strongly supports the necessity of toxicity reduction evaluation as well as toxicity-based effluent management.

상수고도정수처리의 효율적 이용을 위한 경제성 검토 (Economic Feasibility Study on the Efficient Use of Advanced Water Treatment for Water Supply)

  • 이상일
    • 물과 미래
    • /
    • 제29권1호
    • /
    • pp.191-202
    • /
    • 1996
  • 기존의 정수처리기법으로는 처리되지 않는 여러 가지 유기물질의 처리를 위해 상수고도처리가 도입되고 있다. 국내실정에 적합한 고도정수처리 시스템의 개발과 아울러, 이를 실생활에 도입할 경우의 소요비용과 사회적 영향에 대한 연구도 필요하다. 본 연구에서는 고도정수처리시스템의 설비비와 유지보수비를 산정하는 방법을 오존과 활성탄, 그리고 막분리 시스템을 중심으로 제시하고 이를 정부예산과 비교하여 타당성을 검증하였다. 또한 이를 바탕으로 투자비와 시설용랑에 관한 일반적인 관계식도 유도하였다. 한편, 정수된 상질의 물을 수요자에게 공급하는 방안을 네 가지로 검토하고 이를 부산지역에 적용하였다. 생산량과 수송체계에 따른 각각의 대안을 경제적/사회적 측면에서 비교한 결과, 음용수만을 고도정수처리하여 관로를 통하지 않고 병물로 공급하는 방안이 수질을 떨어뜨리지 않으면서 가장 경제성이 있는 방법인것으로 나타났다.

  • PDF

염소의 상수원 내 조류 이취미 Masking 효과 (Masking Effect of Chlorine on Algae-related Taste and Odor in Drinking Water Supplies)

  • 김영일;이유정;신흥섭;배병욱
    • 상하수도학회지
    • /
    • 제22권2호
    • /
    • pp.227-232
    • /
    • 2008
  • The masking effect of chlorine on algae-related taste and odor(T&O) compounds has long been an important issue for water suppliers. In this study, masking experiments with chlorine were performed on two kinds of treated water and one of raw water. After adding chlorine(0 to 0.8 mg/L) to water samples, odor intensity was evaluated by a newly developed sensory method(2-out-of-5 odor test) for three days along with the measurement of residual chlorine concentration. Even though the relationship between the residual chlorine concentration and odor reported by the sensory analysts was not always coincident, it was proved that residual chlorine more than a certain concentration could completely mask both added geosmin and naturally occurring T&O compounds. For the sand-filtered water spiked with 10 ng/L of geosmin, 0.12-0.18 mg/L of residual chlorine was necessary to achieve complete masking. In the case of GAC-filtered water, 10 ng/L of spiked geosmin was completely masked by 0.15-0.1 mg/L of residual chlorine. Combined ozone and GAC was not enough to treat raw water spiked with 300 ng/L of geosmin. In this experiment, sensory analysts were able to detect earthy or musty odors from the treated water. From a masking experiment with raw water taken from the Daechung Reservoir, it was found that fishy odor was more difficult to mask with chlorine than earthy odor. As the chlorine residual declined, the analysts began to notice the original odor and the fishy odor was noticed earlier than the earthy odor.

세라믹막(MF) 고도정수처리에서 NOM 제거 특성 (Removal characteristics of NOM in advanced water treatment using ceramic MF membrane)

  • 유상준;박성한;임재림;서정민;장성호;홍성철;이병인
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.367-376
    • /
    • 2014
  • This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and $UV_{254}$ in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.

Simultaneous water and energy saving of wet cooling towers, modeling for a sample building

  • Ataei, Abtin;Choi, Jun-Ki;Hamidzadeh, Zeinab;Bagheri, Navid
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.173-181
    • /
    • 2015
  • This article outlines a case study of water and energy savings in a typical building through a modelling process and analysis of simultaneous water-energy saving measures. Wet cooling towers are one of the most important equipments in buildings with a considerable amount of water and energy consumption. A variety of methods are provided to reduce water and energy consumption in these facilities. In this paper, thorough the modeling of a typical building, water and energy consumption are measured. Then, After application of modern methods known to be effective in saving water and energy, including the ozone treatment for cooling towers and shade installation for windows, i.e. fins and overhangs, the amount of water and energy saving are compared with the base case using the Simergy model. The annual water consumption of the building, by more than 50% reduction, has been reached to 500 cubic meters from 1024 cubic meters. The annual electric energy consumption has been decreased from 405,178 kWh to 340,944 kWh, which is about 16%. After modeling, monthly peak of electrical energy consumption of 49,428 has dropped to 40,562 kWh. The reduction of 18% in the monthly peak can largely reduce the expenses of electricity consumption at peak.

정수처리 과정에서의 미량오염물질의 거동 및 제거 특성 (Fates and Removals of Micropollutants in Drinking Water Treatment)

  • 남승우;조경덕
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.391-407
    • /
    • 2013
  • Micropollutants emerge in surface water through untreated discharge from sewage and wastewater treatment plants (STPs and WWTPs). Most micropollutants resist the conventional systems in place at water treatment plants (WTPs) and survive the production of tap water. In particular, pharmaceuticals and endocrine disruptors (ECDs) are micropollutants frequently detected in drinking water. In this review, we summarized the distribution of micropollutants at WTPs and also scrutinized the effectiveness and mechanisms for their removal at each stage of drinking water production. Micropollutants demonstrated clear concentrations in the final effluents of WTPs. Although chronic exposure to micropollutants in drinking water has unclear adverse effects on humans, peer reviews have argued that continuous accumulation in water environments and inappropriate removal at WTPs has the potential to eventually affect human health. Among the available removal mechanisms for micropollutants at WTPs, coagulation alone is unlikely to eliminate the pollutants, but ionized compounds can be adsorbed to natural particles (e.g. clay and colloidal particles) and metal salts in coagulants. Hydrophobicities of micropollutants are a critical factor in adsorption removal using activated carbon. Disinfection can reduce contaminants through oxidation by disinfectants (e.g. ozone, chlorine and ultraviolet light), but unidentified toxic byproducts may result from such treatments. Overall, the persistence of micropollutants in a treatment system is based on the physico-chemical properties of chemicals and the operating conditions of the processes involved. Therefore, monitoring of WTPs and effective elimination process studies for pharmaceuticals and ECDs are required to control micropollutant contamination of drinking water.