• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.043 seconds

A Review on the Photochemical Oxidant Modeling as Applied to Air Quality Studies in Complex Terrain

  • Hwa-Woon Lee;Yoo
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.19-33
    • /
    • 1992
  • The high oxidants, which occur the daily maximum concentrations in the afternoon, are transported into the other region via long range transport mechanisms or trapped within the shallow mixing boundary layer and then removed physically (deposition, transport by mountain wind, etc.) and chemically (reaction with local sources). Therefore, modeling formation of photochemical oxidants requires a complex description of both chemical and meteorolog ital processecs . In this study, as a part of air quality studies, we reviewed various aspects of photochemical modeling on the basis of currently available literature. The result of the review shows that the model is based on a set of coupled continuity equations describing advection, diffusion, transport, deposition, chemistry, emission. Also photochemical oxidant models require a large amount of input data concerned with all aspects of the ozone life cycle. First, emission inventories of hydrocarbon and nitrogen oxides, with appropriate spatial and temporal resolution. Second, chemical and photochemical data allowing the quantitative description of the formation of ozone and other photochemically-generated secondary pollutants. Third, dry deposition mechanisms particularly for ozone, PAN and hydrogen peroxide to account for their removal by absorption on the ground, crops, natural vegetation, man-made and water surfaces. Finally, meteorological data describing the transport of primary pollutants away from their sources and of secondary pollutants towards the sensitive receptors where environmental damage may occur. In order to improve our present study, shortcomings and limitation of existing models are pointed out and verification Process through observation is emphasized.

  • PDF

Sterilization of Seawater for the Ballast Water Management System (선박평형수 관리시스템을 위한 해수 살균법)

  • YUN, YONGSUP;CHOI, JONGBEOM;KANG, JUN;LEE, MYEONGHOON
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.172-172
    • /
    • 2016
  • The International Maritime Organization(IMO) adopted the International Convention for the Control and Management of Ships' Ballast Water and Sediments in 2004 to prevent the transfer of aquatic organisms via ballast water. Forty ballast water treatment systems were granted final approval. A variety of techniques have been developed for ballast water treatment including UV treatment, indirect or direct electrolysis, ozone treatment, chemical compounds and plasma-arc method. In particular, using plasma and ozone nano-bubble treatments have been attracted in the fields. However, these treatment systems have a problem such as remained toxic substance, demand for high power source, low efficiency, ets. In this paper, we present our strilization results obtained from membrane type electrolytic-reduction treatment system The core of an electrolysis unit is an electrochemical cell, which is filled with pure water and has two electrodes connected with an external power supply. At a certain voltage, which is called critical voltage, between both electrodes, the electrodes start to produce hydrogen gas at the negatively biased electrode and oxygen gas at the positively biased electrode. The amount of gases produced per unit time is directly related to the current that passes through the electrochemical cell. From the results, we could confirm the sterilization effect of bacteria such as S. aureus, E. Coli and demonstrate the mechanism of sterilization phenomena by electrolytic-reduction treatment system.

  • PDF

The Effect of Ozonized Water Irrigation in the Circuits of Professional Ultrasonic Scalers for Causal Therapy of Stage I Periodontitis: A Randomized Clinical Study

  • Simone Marconcini;Enrica Giammarinaro;Giacomo Oldoini;Annamaria Genovesi
    • Journal of dental hygiene science
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2023
  • Background: Periodontitis is a chronic inflammatory condition associated with dysbiosis of the oral microbiota. The aim of the present clinical study was to explore the adjunctive effect of ozonized water irrigation in the circuits of ultrasonic scalers for the full-mouth decontamination of patients with periodontitis Stage I or II. Methods: The study was a randomized, single-blinded, parallel-group clinical trial. The test group (n=25) was treated with ultrasonic scalers irrigated with ozonized water, whereas the control group (n=25) received normal tap water irrigation within the ultrasonic scalers used during the professional mechanical debridement. Full mouth plaque score, bleeding score, probing pocket depth, and the gingival index were evaluated at baseline, two, and 4 weeks after treatment. The pain perceived and dental anxiety were also assessed after treatment by means of the visual analog scale (VAS). Results: All periodontal parameters resulted in significant improvement for both study groups. The effect of the treatment group on the gingival index was significant, in particular, patients in the test group experienced a greater reduction in this score. No significant differences could be observed with regards to the average probing depth, full mouth plaque index and bleeding score. Patients treated with ozonized water running in the circuits of ultrasonic scalers displayed also lower scores for pain and dental anxiety. Conclusion: The present study showed a significant clinical effect on gingival inflammation attributable to adjunctive ozone irrigation during nonsurgical periodontal therapy. Further studies, including patients with severe periodontitis and greater sample sizes, are recommended to test the clinical effect of ozonized water in the circuits of ultrasonic scalers.

Reduction of Microflora in the Manufacture of Saengshik by Hygienic Processing

  • Bang, Woo-Seok;Eom, Young-Rhan;Oh, Deog-Hwan
    • Preventive Nutrition and Food Science
    • /
    • v.12 no.3
    • /
    • pp.167-172
    • /
    • 2007
  • This study was conducted to determine the effect of hygienic processing (HP) on the reduction of microorganisms during manufacturing of saengshik with two vegetables (carrots and cabbage) and two grains (barely and glutinous rice) compared to general processing (GP). For GP, distilled water was used for washing raw materials and equipment. For HP, aqueous ozone (3 ppm) in combination with 1% citric acid and 70% alcohol were used for washing raw materials and the equipment, respectively. In carrots, after cutting, total aerobic bacteria (TAB), yeast and mold (YM) and coliforms were significantly increased to 5.19, 8.04 and 2.08 ($log_{10}$ CFU/g), respectively (p<0.05). Washing effectively reduced the increased microorganisms from cross contamination during cutting, but cross contamination increased with subsequent GP drying and milling procedures to 8.56, 8.27 and 3.71 ($log_{10}$ CFU/g) for TAB, YM and coliforms, respectively (p<0.05). On the other hand, HP washing of carrots with 3 ppm ozone in combination with 1% citric acid showed higher antimicrobial effect than GP washing, significantly decreasing the number of microorganisms (p<0.05). Further cross contamination did not occur through drying and milling due to cleaning the equipments with 70% alcohol prior to processing. After milling, the number of TAB, YM and coliforms were significantly decreased to 3.89, 4.47 and not detectable level ($log_{10}$ CFU/g), respectively (p<0.05). Similar results were observed in cabbage and grains. During storage for two months at different temperatures (22 or $4^{\circ}C$), there were no changes in numbers of spoilage microorganisms in the packaged saengsik after either processing. This suggests the importance of HP for the reduction of microorganisms during saengsik production, and demonstrates the effectiveness of disinfection at each processing stage in minimizing contamination levels to enhance microbial safety of saengshik products.

A Study on Substrate Pre-treatment for Mathane Production Performance (메탄생성 효율증진을 위한 소화원료 전처리 연구)

  • Jeong, K.H.;Ryu, S.H.;NamGung, K.C.;Kim, J.H.;Kwag, J.H.;Ann, H.K.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.197-204
    • /
    • 2011
  • During the process of anaerobic digestion, hydrolysis of substrate is the key factor determining methane production efficiency. The hydrolysis efficiency are directly affected by biodegradability of substrate. In this study, three types of pre-treatment methods were tested to enhance biodegradability effectiveness. By the application of blender and the Cavitation treatment, the SCODcr increased from 24,723 mg/l to 24.726~29,175 mg/l and to 25,589~26,456 mg/l, respectively. In case of ozone treatment, the SCODcr decreased from 24,723 mg/l to 22.540~23,988 mg/l. In batch experiment, there was a little improvement of the biochemical methane potential (BMP) by the blender and the cavitation treatment. In contrast, the BMP somewhat decreased by ozone treatment. This result shows that higher anaerobic digestion efficiency of livestock manure could be obtained through pre-treatment of substrate.

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

Treatment of surface water using cold plasma for domestic water supply

  • Nguyen, Dung Van;Ho, Phong Quoc;Pham, Toan Van;Nguyen, Tuyen Van;Kim, Lavane
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.412-417
    • /
    • 2019
  • This paper presents the results of using cold plasma to treat surface water for domestic use purpose. Experimental results showed that cold plasma was an effective method for destroying bacteria in water. After treatment with cold plasma, concentration of coliform and Escherichia coli dramatically reduced. Besides, cold plasma significantly removed water odor, increased dissolved oxygen and decreased the concentration of chemical oxygen demand. However, cold plasma significantly raised the concentration of nitrite and nitrate. Other disadvantages of treating with cold plasma were conductivity increase and pH reduction. Pretreatment steps of coagulation, flocculation, sedimentation and sand filtration followed by disinfection with cold plasma exhibited a high efficiency in surface water treatment. All parameters of surface water after treatment by using the prototype satisfied with the allowance standard of domestic water quality.