• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.03 seconds

Peroxone ($O_3/H_2O_2$) Process in Drinking Water Treatment (정수처리에서의 Peroxone ($O_3/H_2O_2$) 공정)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Bin, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.296-308
    • /
    • 2010
  • The peroxone process overcomes many of the limitations associated with conventional and advanced water treatment systems using chlorine disinfection and ozone oxidation processes. Ozone and hydrogen peroxide generate highly reactive hydroxyl free radical which oxidize various organic compounds and has highly removal efficiency. The key issue to operate peroxone process is developing the method to achieve high process effectiveness when scavengers that inhibit generation of OH radicals or consume OH radicals are co-existing in the process. Also many studies, to minimize inorganic oxidative by-products such as bromate and to reduce disinfection by-products after chlorination behind peroxone process, are needed. And we should consider the excess residual hydrogen peroxide in the water. On-line instruments and control strategies need to be developed to ensure effective and robust operation under conditions of varying load. If problems above mentioned are solved, peroxone process will be applied diversely for water treatment.

Changes in Properties of Tropical Kapok Fibers by the Pretreatments (열대산 케이폭 섬유의 전처리에 따른 특성 변화)

  • Shin, Soo-Jeong;Jung, Woong-Ki;Sung, Yong Joo;Lee, Joon-Woo;Kim, Se-Bin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • The effets of the pretreatments of tropical kapok fibers were evaluated in this study in terms of water sorption capacity and oil sorption capacity. The alkali treatments with NaOH resulted in the reduction of lignin, oil and hemicellulose, which were detected with FT-IR spectrum. The reduction of the lyphophilic components such as fat on kapok fiber by the ozone treatments were also measured with FT-IR spectrum. The oil sorption capacity of kapok fiber was decreased by the alkali treatments and the ozone treatments, while the water sorption capacity was increased. The liquid sorption capacity were greatly affected by the mechanical cutting of kapok fiber which exposed the big lumen of kapok fiber. The hydrophilic property of kapok fiber could be controlled by the pretreatments, which would increase the applicability of kapok fiber for preparation of various functional paper products.

A Study on the Degradation of PAH in Organic and Aqueous Phases by Ozone (다환방향족탄화수소에 대한 오존처리의 방법에 관한 연구)

  • Choi, Young Ik;Son, Hee-Jong;Jung, Chul-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1123-1129
    • /
    • 2006
  • Pyrene of natural and anthropogenic sources is one of the toxic, mutagenic polycyclic aromatic hydrocarbons (PAHs) listed as priority pollutants. The objectives of this research are to break down pyrene by using ozonation, identify the intermediates and byproducts of pyrene, and test the biodegradability of intermediates and byproducts of pyrene in the aqueous phase. Since pyrene is non-polar, hexane was chosen as a solvent to effectively dissolve pyrene. Pyrene solutions were treated with ozone, as it has high oxidation capacity and electrophilic characteristic. After different ozonation pretreatment times (2, 3, and 10 minutes), intermediates of pyrene in the form of yellowish solid were collected from the hexane solution using a centrifuge. They were identified by gas chromatography/mass spectrometer (GC/MS). $BOD_5$, COD, and E-coli toxicity tests have been performed to assess the ozonation products.

Improvement of Gas Dissolution Rate using Air Atomizing Nozzle (이류체 노즐을 이용한 가스의 용존율 향상)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.219-225
    • /
    • 2018
  • This study was conducted to investigate the possibility of utilizing various types of nozzles and gas-liquid mixers to increase the dissolution rate of plasma gas containing ozone generated in a dielectric barrier plasma reactor. After selecting the air atomizing nozzle with the highest gas dissolution rate among the 13 types of test equipment, we investigated the influence of the operating factors on the air atomizing nozzle to determine the optimal plasma gas dissolution method. The gas dissolution rate was measured by a simple and indirect method, specifically, the measurement of KLa instead of direct measurement of ozone concentration, which requires a longer analysis time. The results showed that the KLa value of the simple mix of air and water was $0.372min^{-1}$, Which is 1.44 times higher than that ($0.258min^{-1}$) of gas emitted from a normal diffuser. Among the nozzles of the same type, the KLa value was highest for the nozzle having the smallest orifice diameter. Among the 13 types of devices tested, the nozzle with highest KLa value was the M22M nozzle, which is a gas-liquid spray nozzle. The relationship between water circulation flow rate and KLa value in the experimental range was linear. The air supply flow rate and KLa value showed a parabolic-type correlation, while the optimum air supply flow rate for the water circulation flow rate of 1.8 L / min is 1.38 times.

Study on the Removal of Fluorescent Whitening Agent by Pretreatment Ozone Oxidation for MBR Process Application (MBR 공정 적용을 위한 전처리 오존산화에 의한 형광증백제 제거 연구)

  • Choi, Jang-Seung;Ryu, Seung-Han;Shin, Dong-Hun;Lee, Jae-Hun;Lee, Soo-Chol;Kim, Sung-Gi;Ryu, Jae-Young;Shin, Won-Sik;Lee, Seul-Ki;Park, Min-Soo
    • Textile Coloration and Finishing
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2017
  • In this study, ozone oxidation experiment was carried out for the removal of fluorescent whitening agent which is widely used in textile dyeing and paper industry. The stilbene fluorescent whitening agent has been industrialized since the earliest, and the amount of current production is the highest. Due to the characteristics of the fluorescent whitening agent that can not be removed by conventional wastewater treatment methods, the fluorescent whitening agent in wastewater treatment has difficulty in using as recycled water in the process. Pre-treatment ozone oxidation experiment was conducted prior to the introduction of Membrane Bio Reactor(MBR) treatment process by converting biodegradable materials into biodegradable materials. The removal efficiencies of fluorescent whitening agents, a diaminostilbenedisulfonic acid derivative by ozone oxidation were evaluated by $UV_{254}$ Scan, $COD_{Mn}$, T-N and color using a synthetic wastewater sample ($COD_{Mn}=433.0mg/{\ell}$) and paper and paper mill wastewater ($COD_{Mn}=157.2mg/{\ell}$).

New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

Removal Characteristics of Dichloroacetic Acid at Different Catalyst Media with Advanced Oxidation Process Using Ozone/Catalyst (담지체를 달리한 오존/촉매 AOP공정에서 디클로로아세트산의 제거 특성)

  • Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.87-93
    • /
    • 2009
  • Pd/activated carbon (Pd/AC) and Pd/alumina (Pd/AO) catalysts were prepared by the impregnation of palladium into activated carbon and alumina. The catalytic characteristics according to the kinds of support materials were compared. The decomposition efficiencies of ozone according to kinds of support materials are about the same when these were compared by adding 10 g of catalysts into the water saturated with ozone. The decomposition efficiencies and the oxidation characteristics (TOC, $COD_{Cr}$) of dichloroacetic acid were compared with the ozone only process and the catalytic ozonations using Pd/activated carbon and Pd/alumina catalysts. The decomposition efficiencies of dichloroacetic acid by catalytic ozonations were better than the one by ozone only process, but there was slight difference of the one between Pd/activated carbon and Pd/alumina catalyst. The decomposition efficiency of dichloroacetic acid was increased with increasing ozone dose at a constant concentration of dichloroacetic acid, but the one was little increased with increasing ozone dose at more than 1.0 L/min of ozone dose. It was seemed that the bicarbonate and the chloric ion formed throughout the decomposition of dichloroacetic acid acted as the scavenger of hydroxyl radical.

A Study on the Distribution Characteristics of Bromide and Bromate in Drinking Water in Northern Gyeonggi Area (경기북부지역 먹는 물 중 브롬이온 및 브롬산염의 분포특성에 관한 연구)

  • Jung, Jong-Pil;Choi, Si-Rim;Ryu, Hyeung-Rial;Park, Gyoung-Su;Song, Hee-Il;Lee, Hyun-Jin;Jo, Mi-Hyun;Oh, Jo-Gyo;Yoon, Mi-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.244-249
    • /
    • 2018
  • Objectives: The purpose of this study was the investigation of bromide and bromate in drinking water of water supply plants, mineral springs and small water supply system located in northern area of Gyeonggi province. Methods: Analytical method was based on EPA 326.0 to use Postcolumn reaction (PCR). The instrument was 887 professional UV/VIS detector IC manufactured in Metrohm. Results: Bromate was detected at $0.5{\sim}2.4{\mu}g/L$ in tap water from 5 water supply plants. These plants were used as disinfection method for sodium hypochlorite and on-site chlorine that causes generate bromate as a by products even if not used ozone. Conclusions: The bromate was detected up to $2.5{\mu}g/Lin$ drinking water in northern Gyeonggi area that showed within $10{\mu}g/L$ for standard of tap water. However, the continuous monitoring of bromate is necessary in drinking water.

Disinfection effect of corona discharged plasma water on fish pathogens (코로나 방전 플라즈마 처리수에 의한 어류 병원체 소독 효과)

  • You, Jin Ho;Lee, Ji Hyun;Mun, Seong Hee;Kwon, Se Ryun;Park, Tae Sup;Kwon, Joon Yeong
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.63-69
    • /
    • 2020
  • Fish culture is constantly threatened by various infectious diseases which are largely transmitted by water. Plasma technology is being used to sterilize polluted water in many industries. In this study, two bacterial pathogens Aeromonas salmonicida and Streptococcus iniae, and a virus (viral hemorrhagic septicemia virus, VHSV) were subjected to plasma water that was produced by a corona discharge system. Growth of A. salmonicida was greatly inhibited from 105.61 CFU/ml in positive control to 103.51 CFU/ml in treated group by only 60 sec contact with plasma water. Similarly, S. iniae was inhibited from 105.85 CFU/ml to 103.40 CFU/ml. VHSV titer also decreased from 104.1 TCID50/ml to 101.45 TCID50/ml by the same treatment. Activation of water by the plasma was confirmed by the existence of ozone in the plasma water. These results suggest that plasma water could efficiently disinfect fish pathogens, possibly by the action of reactive oxygen species contained in the plasma water.

Effect of Ozonation and Coagulation on NOM Molecular Distribution and Activated Carbon Adsorption Capacity (응집과 오존처리가 NOM 분자량 분포특성과 활성탄 흡착능에 미치는 영향)

  • Kim, Sung Jin;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.480-486
    • /
    • 2005
  • The main goals of this work are to investigate the effect of molecular weight distribution(MWD) and activated carbon adsorption capacity after conventional coagulation and enhanced coagulation. The ozonation was very effective to decompose the NOM to smaller size and to remove molecular smaller than 1,000. The concentration of DOC was reduced 0.25mg/L and 0.56mg/L by the conventional coagulation and the enhanced coagulation, respectively The conventional coagulation was not effective to remove NOM. However, the enhanced coagulation was effective to remove MW bigger than 10,000. The higher MW was shifted to smaller weight by ozonation in the raw water and the after conventional coagulation. After enhanced coagulation the MW had not changed significantly by ozonation. Also, it was observed that the ozone dosage did not have significant impact on MW shifting to smaller size. The adsorption capacity simulated by IAST comparing K values showed that the adsorption capacity was not impacted by ozone doses. There was very strong correlation between MW smaller than 10,000 and the mid- and strongly adsorbable fractions.