• Title/Summary/Keyword: ozone monitoring

Search Result 174, Processing Time 0.025 seconds

Ozone Simulation and Sensitive Test under Varying Emission Condition (오존농도 시뮬레이션과 배출량 변화에 따른 민감도 분석)

  • Han, Jin-Seok;Kim, Byung-Gon;Kim, Shin-Do
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.69-77
    • /
    • 1996
  • The variations of ozone concentration and the sensitivity test for VOC emission intensities was investigated by means of a PBM(Photochemical Box Model). Compared to monitoring data, the typical variations of $NO_2$, CO, $O_3$ for days were successfully reproduced. Model results revealed that maximum ozone concentration got increased with the increase of VOC emission, that is, VOC played the important role in producing the photochemical smog.

  • PDF

Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas (중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교)

  • Lee, Yong-Ki;Kim, Woong-Soo;Hong, Soon-Mo;Shin, Eun-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.

On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002 (지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징)

  • Kim C.-H;Park I.-S;Lee S.-J;Kim J.-S;Jin H.-A;Sung H.-G
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

Automation of Dobson Spectrophotometer(No.124) for Ozone Measurements (돕슨 분광광도계(No.124)의 오존 자동관측시스템화)

  • Kim, Jhoon;Park, Sang-Seo;Moon, Kyung-Jung;Koo, Ja-Ho;Lee, Yun-Gon;Miyagawa, Koji;Cho, Hi-Ku
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.339-348
    • /
    • 2007
  • Global Environment Laboratory at Yonsei University in Seoul ($37.57^{\circ}N$, $126.95^{\circ}E$) has carried out the ozone layer monitoring program in the framework of the Global Ozone Observing System of the World Meteorlogical Organization (WMO/GAW/GO3OS Station No. 252) since May of 1984. The daily measurements of total ozone and the vertical distribution of ozone amount have been made with the Dobson Spectrophotometer (No.124) on the roof of the Science Building on Yonsei campus. From 2004 through 2006, major parts of the manual operations are automated in measuring total ozone amount and vertical ozone profile through Umkehr method, and calibrating instrument by standard lamp tests with new hardware and software including step motor, rotary encoder, controller, and visual display. This system takes full advantage of Windows interface and information technology to realize adaptability to the latest Windows PC and flexible data processing system. This automatic system also utilizes card slot of desktop personal computer to control various types of boards in the driving unit for operating Dobson spectrophotometer and testing devices. Thus, by automating most of the manual work both in instrument operation and in data processing, subjective human errors and individual differences are eliminated. It is therefore found that the ozone data quality has been distinctly upgraded after automation of the Dobson instrument.

Prediction of Ozone Concentration by Multiple Regression Analysis in Daegu area (다중회귀분석을 통한 대구지역 오존농도 예측)

  • 최성우;최상기;도상현
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.687-696
    • /
    • 2002
  • Air quality monitoring data and meteorology data which had collected from 1995. 1. to 1999. 2. in six areas of Daegu, Manchondong, Bokhyundong, Deamyungdong, Samdukdong, Leehyundong and Nowondong, were investigated to determine the distribution and characteristic of ozone. A equation of multiple regression was suggested after time series analysis of contribution factor and meteorology factor were investigated during the day which had high concentration of ozone. The results show the following; First, 63.6% of high ozone concentration days, more than 60 ppb of ozone concentration, were in May, June and September. The percentage of each area showed that; Manchondong 14.4%, Bokhyundong 15.4%, Deamyungdong 15.6%, Samdukdong 15.6%, Leehyundong 17.3% and Nowondong 21.6%. Second, correlation coefficients of ozone, $SO_2$, TSP, $NO_2$ and CO showed negative relationship; the results were respectively -0.229, -0.074, -0.387, -0.190(p<0.01), and humidity were -0.677. but temperature, amount of radiation and wind speed had positive relationship; the results were respectively 0.515, 0.509, 0.400(p<0.01). Third, $R^2$ of equation of multiple regression at each area showed that; Nowondong 45.4%, Lee hyundong 77.9%, Samdukdong 69.9%, Daemyungdong 78.8%, Manchondong 88.6%, Bokhyundong 77.6%. Including 1 hour prior ozone concentration, $R^2$ of each area was significantly increased; Nowondong 75.2%, Leehyundong 89.3%, Samdukdong 86.4%, Daemyungdong 88.6%, Manchondong 88.6%, Bokhyundong 88.0%. Using equation of multiple regression, There were some different $R^2$ between predicted value and observed value; Nowondong 48%, Leehyundong 77.5%, Samdukdong 58%, Daemyungdong 73.4%, Manchondong 77.7%, Bokhyundong 75.1%. $R^2$ of model including 1 hour prior ozone concentration was higher than equation of current day; Nowondong 82.5%, Leehyundong 88.3%, Samdukdong 80.7%, Daemyungdong 82.4%, Manchondong 87.6%, Bokhyundong 88.5%.

Evaluation of the Total Column Ozone in the Reanalysis Datasets over East Asia (동아시아 지역 오존 전량 재분석 자료의 검증)

  • Han, Bo-Reum;Oh, Jiyoung;Park, Sunmin;Son, Seok-Woo
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.659-669
    • /
    • 2019
  • This study assesses the quality of the total column ozone (TCO) data from five reanalysis datasets against nine independent observation in East Asia. The assessed datasets are the ECMWF Interim reanalysis (ERAI), Monitoring Atmosphere Composition and Climate reanalysis (MACC), Copernicus Atmosphere Monitoring Service reanalysis (CAMS), the NASA Modern-Era Retrospective analysis for Research and Applications, Version2 (MERRA2), and NCEP Climate Forecast System Reanalysis (CFSR). All datasets reasonably well capture the spatial distribution, annual cycle and interannual variability of TCO in East Asia. In particular, characteristics of TCO according to the latitude difference were similar at all points with a maximum bias of less than about 4%. Among them, CAMS and CFSR show the smallest mean bias and root-mean square error across all nine ground-based observations. This result indicates that while TCO data in modern reanalyses are reasonably good, CAMS and CFSR TCO data are the best for analysing the spatio-temporal variability and change of TCO in East Asia.

Monitoring of the Atmospheric Aerosol using TOMS Aerosol Index Data (TOMS(Total Ozone Mapping Spectrometer) Aerosol Index자료를 이용한 대기 에어로졸 모니터링)

  • 이권호;김영준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.441-442
    • /
    • 2001
  • TOMS (Total Ozone Mapping Spectrometer)는 Nimbus-7과 Meteor-3에 탑재되어 자외선 영역에서 오존의 양을 측정하는 임무를 가지고 1978년부터 1994년 12월까지 일별 오존자료를 제공하였다. 1996년 8월 17일에 발사된 일본의 ADEOS에 탑재된 TOMS는 1997년 6월 29일까지 자료를 생산했으며 1996년7월 2일 발사된 Earth Probe의 TOMS는 현재까지 실시간 자료를 보내오고 있다. TOMS는 지구의 대기에 의해 반사된 태양 광선중의 자외선 자료를 통해 오존의 양을 간접적으로 측정하는 것이 원리이다. (중략)

  • PDF

Characteristics and Prediction of Total Ozone and UV-B Irradiance in East Asia Including the Korean Peninsula (한반도를 포함한 동아시아 영역에서 오존전량과 유해자외선의 특성과 예측)

  • Moon, Yun-Seob;Seok, Min-Woo;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.701-718
    • /
    • 2006
  • The average ratio of the daily UV-B to total solar (75) irradiance at Busan (35.23$^{\circ}$N, 129.07$^{\circ}$E) in Korea is found as 0.11%. There is also a high exponential relationship between hourly UV-B and total solar irradiance: UV-B=exp (a$\times$(75-b))(R$^2$=0.93). The daily variation of total ozone is compared with the UV-B irradiance at Pohang (36.03$^{\circ}$N, 129.40$^{\circ}$E) in Korea using the Total Ozone Mapping Spectrometer (TOMS) data during the period of May to July in 2005. The total ozone (TO) has been maintained to a decreasing trend since 1979, which leading to a negative correlation with the ground-level UV-B irradiance doting the given period of cloudless day: UV-B=239.23-0.056 TO (R$^2$=0.52). The statistical predictions of daily total ozone are analyzed by using the data of the Brewer spectrophotometer and TOMS in East Asia including the Korean peninsula. The long-term monthly averages of total ozone using the multiplicative seasonal AutoRegressive Integrated Moving Average (ARIMA) model are used to predict the hourly mean UV-B irradiance by interpolating the daily mean total ozone far the predicting period. We also can predict the next day's total ozone by using regression models based on the present day's total ozone by TOMS and the next day's predicted maximum air temperature by the Meteorological Mesoscale Model 5 (MM5). These predicted and observed total ozone amounts are used to input data of the parameterization model (PM) of hourly UV-B irradiance. The PM of UV-B irradiance is based on the main parameters such as cloudiness, solar zenith angle, total ozone, opacity of aerosols, altitude, and surface albedo. The input data for the model requires daily total ozone, hourly amount and type of cloud, visibility and air pressure. To simplify cloud effects in the model, the constant cloud transmittance are used. For example, the correlation coefficient of the PM using these cloud transmissivities is shown high in more than 0.91 for cloudy days in Busan, and the relative mean bias error (RMBE) and the relative root mean square error (RRMSE) are less than 21% and 27%, respectively. In this study, the daily variations of calculated and predicted UV-B irradiance are presented in high correlation coefficients of more than 0.86 at each monitoring site of the Korean peninsula as well as East Asia. The RMBE is within 10% of the mean measured hourly irradiance, and the RRMSE is within 15% for hourly irradiance, respectively. Although errors are present in cloud amounts and total ozone, the results are still acceptable.