• 제목/요약/키워드: ozone episode

검색결과 57건 처리시간 0.019초

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

OZIPR을 이용한 부산지역 고농도 오존 사례 모사 (A Numerical Simulation of High Ozone Episode Using OZIPR in Busan)

  • 도우곤;이화운;정우식
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.985-994
    • /
    • 2007
  • To investigate the effect of NOx and VOCs(volatile organic compounds) on the generation of high ozone episode, examined the hourly variations of ozone, NOx and VOCs concentrations, and calculated the ozone isopleth about maximum ozone concentrations using OZIPR which was presented by U. S. EPA at three sites in Busan. There was some difference by the sites, but decreasing VOCs concentration was effective for reduction of ozone at 22 July, the episode day of 2005. In the year 2006, the episode day was 8 August and the variations of NOx and VOCs concentration was little than variation of ozone. So it was estimated that the photochemical production of ozone was low than transportation of ozone. And the result of the OZIPR modeling was that decreasing VOCs concentration was effective for reduction of ozone.

대구시 고농도 오존 사례일인 경우 대기 오염물질 농도의 일변화 특성 (Characteristics of Diurnal Variation of the Atmospheric Pollutants Concentration in High-Ozone Episode day in Daegu)

  • 손임영;윤일희;김희종
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1253-1259
    • /
    • 2002
  • This study analyzes the surface ozone, NO and $NO_2$ concentration data from 1997 to 1999 in Daegu. It investigates effect on precursor during high-ozone episode days. The high-ozone episode is defined when a daily maximum ozone concentration is higher than 100 ppb(ambient air quality standard of Korea) in at least one station among six air quality monitoring stations. The frequency of episodes is 13 days(33 hours). The frequency is the highest in May and September, and the area with the highest frequency is Nowondong and Manchondong. The average value of daily maximum ozone concentration with high ozone episode is 81.6 ppb, and that of 8-hour average ozone concentration is 58.6 ppb. It means that ozone pollution is continuous and wide-ranging in Daegu. The daily variation of NO, $NO_2$ and $O_3$ in high-ozone episodes are inversely proportional one another. Nowondong an industrial area, is affected by pollutants that are emitted from the primary sources, while Manchondong a residential area, is affected by the advection of $O_3$ or by the primary pollutants like VOCs.

부산 지역의 오존 농도 특징과 기상 인자에 관한 연구 (On Characteristics of Surface Ozone Concentration and Important Meteorological Parameters in Pusan, Korea)

  • 전병일;김유근;이화운
    • 한국대기환경학회지
    • /
    • 제11권1호
    • /
    • pp.45-56
    • /
    • 1995
  • We considered that characteristics of surface ozone continuous and important meteorological parameters from the data measured 7 air quality continuous monitoring stations during 2 years (1990, 1993) in pusan. The diurnal ozone variation showed a primary peak near 1500LST and a secondary peak of the DP(double peaked) pattern. The episode day was defined when an ozone peak higher than 60 ppb was observed at least one station. The frequency of episode day was 100 (298 hours, 69 days). The frequency of the episode day was higher at Meongryundong and Daeyeondong than other sites and highest in August under control of pacific subtropical high. The high temporatant meteorological parameters accompanying the high episode days. The favorable synoptic environment accompanying ozone episode was distributed to 7 different pattern. These pattern can be taken as a nesessary but not an absolute indicator for predicting the occerrence of an episode.

  • PDF

CMAQ을 이용한 수도권 풍하지역의 고농도 오존 현상 모사 (A Simulation of High Ozone Episode in Downwind Area of Seoul Metropolitan Using CMAQ Model)

  • 이종범;송은영
    • 환경영향평가
    • /
    • 제15권3호
    • /
    • pp.193-206
    • /
    • 2006
  • Recently, high ozone episode occurred frequently in Korea. Moreover ozone episode occurred not only in the city but also in background area where local anthropogenic sources are not important. It analyzed frequency exceeding 100ppb ozone at air quality monitoring stations in Seoul and rural area during 1995-2004. This paper reports on the use of the Community Multiscale Air Quality (CMAQ) modelling system to predict hourly ozone levels. Domain resolutions of 30km, 10km, 3.333km (innermost) have been employed for this study. Summer periods in June 2004 have been simulated and the predicted results have been compared to data for metropolitan and rural air quality monitoring stations. The model performance has been evaluated with measured data through a range of statistical measures. Although, the CMAQ model reproduces the ozone temporal spatial trends it was not able to simulate the peak magnitudes consistently.

HDDM과 BFM을 이용한 NOx와 VOC 배출량에 대한 오존민감도계수 산정 및 결과 비교: 2007년 6월 수도권 사례 (Estimating Ozone Sensitivity Coefficients to NOx and VOC Emissions Using BFM and HDDM for A 2007 June Episode)

  • 김순태
    • 한국환경과학회지
    • /
    • 제20권11호
    • /
    • pp.1465-1481
    • /
    • 2011
  • The accuracy of ozone sensitivity coefficients estimated with HDDM (High-order Decoupled Direct Method) can vary depending on the $NO_x$ (Nitrogen Oxides) and VOC (Volatile Organic Compound) conditions. In order to evaluate the applicability of HDDM over the Seoul Metropolitan Area (SMA) during a high ozone episode in 2007 June, we compare BFM (Brute Force Method) and HDDM in terms of the $1^{st}$-order ozone sensitivity coefficient to explain ozone change in response to changes in NOx and VOC emissions, and the $2^{nd}$-order ozone sensitivity coefficient to represent nonlinear response of ozone to the emission changes. BFM and HDDM estimate comparable ozone sensitivity coefficients, exhibiting similar spatial and temporal variations over the SMAduring the episode. NME (Normalized Mean Error) between BFM and HDDM for the episode average $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients to NOx and VOC emissions are less than 3% and 9%, respectively. For the daily comparison, NME for the $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients are less than 4% ($R^2$ > 0.96) and 15% ($R^2$ > 0.90), respectively. Under the emission conditions used in this study, two methods show negative episode average $1^{st}$-order ozone sensitivity coefficient to $NO_x$ emissions over the core SMA. The $2^{nd}$-order ozone sensitivity coefficient to $NO_x$ emissions leads ozone to respond muchnonlinear to the reduction in $NO_x$ emissions over Seoul. Nonlinear ozone response to reduction in VOC emissions is mitigated due to the $2^{nd}$-order ozone sensitivity coefficient which is much smaller than the $1^{st}$-order ozone sensitivity coefficient to the emissions in the magnitude.

서울.수도권 지역 고농도 오존 사례의 지상 및 종관 기상 특성 (Characteristics of Surface and Synoptic Meteorology During High-Ozone Episodes in the Greater Seoul Area)

  • 오현선;김영성
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.441-455
    • /
    • 1999
  • Meteorological characteristics of three high-ozone episodes in the Greater Seoul Area, selected on the basis of morning-average wind direction and speed for the 1990~1997 period, were investigated. Three high-ozone episodes thus selected were seven days of July 3~9, 1992, nine days of July 21~29, 1994, and three days of August 22~24, 1994. Along with surface meteorological data from the Seoul Weather Station, surface and 850-hPa wind fields over the Northest Asia around the Korean Peninsula were used for the analysis. In the July 1992 episode, westerly winds were most frequent as a result of the influence of a high-pressure system in the west behind the trough. In contrast, in the July 1994 episode, easterly winds were most frequent due to the effect of a typhoon moving north from the south of Japan. Despite different prevailing wind directions in the two episodes, the peak ozone concentration of each episode always occurred when a sea-land breeze developed in association with weak synoptic forcing. The August 1994 episode, selected as being representative of calm conditions, was another typical example in which peak ozone concentration rose to 322 ppb under the well-developed sea-land breeze. All three high-ozone episodes were terminated by precipitation, and subsequent rises in ozone concentrations were also suppressed by a series of precipitation afterwards. In particular, two heavy rainfalls were the main reason why the August 1994 episode, with the highest and second-highest ozone concentrations during the 1990~1997 period, lasted for only a few days.

  • PDF

부산지역 여름철 고농도 오존 발생의 사례 연구 (Case Study for High Ozone Episode day during Summertime in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제12권4호
    • /
    • pp.303-313
    • /
    • 2003
  • This study was carried out to survey the high ozone episode of summertime in Busan. The selected day was July 18, 1999 and August 24, 2001 which recorded exceed to 12ppb/hr at 3 station in Busan simultaneously. In case July 18, 1999, thick cloud and variable wind made weak ozone concentration during morning hour. And increase of ozone concentration by revolution of mixed layer for morning hour did not occur in this case study day. Photochemical reaction by strong radiation after 1100LST made sharp increase rate of ozone concentration(50ppb/hr). In case August 24, 2001, the meteorological condition of this day was not general wind with gradient force, very clear day with less cloud amount, high insolation and sunshine. Dongsamdong, Beomcheondong, Daeyeondong, and Sinpyeongdong had double peak which twice maximum concentration in the early afternoon and late afternoon. Ozone concentration of this day was in inverse proportion to Nitrogen oxide strongly. Ozone concentration exceed to 60ppb/hr occurred at 1400LST, continued to 2300LST.

부산 연안역의 오존 농도에 미치는 해풍의 영향 (The Influences of 5ea Breeze on Surface Ozone Concentration in Pusan Coastal Area, Korea)

  • 김유근;이화운
    • 한국환경과학회지
    • /
    • 제5권3호
    • /
    • pp.265-275
    • /
    • 1996
  • Air pollution characteristics and the influence of sea breeze on surface ozone concentration were studied using the data measured at 7 air quality continuous monitoring stations from June to September using 3 years (1990, 1993, 1994) in Pusan coastal area. Among the 246 sea breeze days for research Period, there were approximately 89 sea breeze days (36%) from lune to September, And there were 120 the episode days (68%) of ozone greater than or equal to 60 ppb in summer season. In 89 sea breeze days, the episode day was highly marked as 56 days (63%). So, we knew that the sea breeze greatly affects the occurence of ozone episode day. the ozone concentration under the condition of the sea breeze increase about 40% in the daytime. Frequencies distribution of $O_3$ concentration for sea breeze moved toward high concentration class. The characteristics of ozone concentration in relation to meteorological conditions of sea breeze is significant because we can discover major weather factors for eastablishing an air pollution- weather forecast system. For further. study about meterological approach method for photochemical air pollution, it is necessary to explain the characteristics of atmosphere below 1, 000 m, especially concerning the formation mechanism of inversion layers. And finally, we will study the relationships to synoptic weather conditions and vertical structure and diurnal variation of local wind systems including sea breeze, and the vertical movements of atmosphere in the city.

  • PDF

봄철 서울지역 야간 오존농도 상승에 미치는 장거리 수송의 영향 (The Influence of Long-range Transport on Springtime Nocturnal Ozone Enhancement in Seoul)

  • 오인보;김유근
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.503-514
    • /
    • 2004
  • In Seoul metropolitan area, nocturnal variation of surface ozone concentrations observed at 27 monitoring sites from 1998 to 2002 showed that high ozone levels occurred frequently during the spring. Frequency distributions for nighttime ozone indicated that elevated concentrations in spring were influenced by advection of different air mass compared to other seasons. Surface wind analysis during the spring revealed that relatively strong southwesterly winds were associated with nocturnal ozone enhancement, which can be attributed to the regional transport of ozone. In order to identify the origin of nocturnal ozone enhancement in spring, 3-day backward trajectories were calculated by HYSPLIT 4 for the episode days and then classified. The results showed that NW, W, and SW flows, indicating influence of polluted air masses from the China continent, have 51% in a]1 the episode days, which suggest that the nocturnal ozone enhancement can occur under the effect of long-range transport of ozone-laden air mass on a regional scale. Case study of nocturnal ozone maxima associated with long-range transport was discussed in more detail in the light of meteorological conditions. Southwesterly synoptic flow along the outer edge of moving high-pressure system was found to be the important cause of nocturnal ozone maxima in Seoul. This flow could lead to be long-range transport of ozone that had effectively accumulated in the stagnating portion of the system located eastern coast of China. Low atmosphere soundings, backward trajectories, and elevated ozone and CO levels at the back-ground tiles gave evidence for regional effects on nocturnal ozone enhancement In Seoul.