• 제목/요약/키워드: ozone control strategy

검색결과 14건 처리시간 0.022초

서울시에서의 최적 오존 저감 대책: OZIPR을 이용한 사례 연구 (On the Optimum Ozone Control Strategy in Seoul: Case Studies Using OZIPR)

  • 박주연;김용표
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.427-433
    • /
    • 2002
  • In this discussion, an optimum ozone control strategy for the city of Seoul is discussed based on the OZIPR simulation results for three cases. It is claimed that, for the periods we have simulated, it is best to decrease VOCs emissions and increase NO$_{x}$ emissions to reduce the ambient maximum ozone concentration.n.

A Study on the Ozone Control Strategy using the OZIPR in the Seoul Metropolitan Area

  • Jin, Lan;Lee, Sun-Hwa;Shin, Hye-Jung;Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.111-117
    • /
    • 2012
  • To establish area specific control strategy for ambient ozone in the Seoul Metropolitan Area (SMA), the maximum ozone concentration in each local government district in the SMA were estimated by using the OZone Isopleth Plotting Package for Research (OZIPR) model. The modeling period was June 2000 and the emission inventory data used were from National Institute of Environmental Research (NIER). Except the islands of Incheon, whole Seoul and Incheon areas were volatile organic compounds (VOCs) limited, i.e., decreasing the oxides of nitrogen ($NO_X$) emission alone may increase the maximum ozone concentration upto certain point. In Gyeonggi, 12 areas were VOCs limited while 12 areas were in between VOCs limited and $NO_X$ limited, i.e., decreasing both $NO_X$ and VOCs emission may decrease the maximum ozone concentration. Majority of the estimated ozone values were lower than the measured values. The reason could be inaccuracy in emission inventories and/or transport from other areas. The same calculation was carried out for June 2004 and it was found that Seoul was still in the VOCs limited condition.

Assessing Factors Linked with Ozone Exceedances in Seoul, Korea through a Decision Tree Algorithm

  • Park, Sun-Kyoung
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.191-216
    • /
    • 2016
  • Since prolonged exposure to elevated ozone ($O_3$) concentrations is known to be harmful to human health, appropriate control strategies for ozone are needed for the non-attainment area such as Seoul, Korea. The goal of this research is to assess factors linked with the 1-hour ozone exceedance through a decision tree model. Since ozone is a secondary pollutant, lag times between ozone and explanatory variables for ozone formation are taken into account in the model to improve the accuracy of the simulation. Results show that while ozone concentrations of the previous day and $NO_2$ concentrations in the morning are major drivers for ozone exceedances in the early afternoon, meteorology plays more important role for ozone exceedances in the late afternoon. Results also show that a selection of lag times between ozone and explanatory variables affect the accuracy of predicting 1-hour ozone exceedances. The result analyzed in this study can be used for developing control strategies of ozone in Seoul, Korea.

구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터 (The Invert for ozone generator by mixed square_wave and PWM)

  • 박노식;박성준;원태헌;안진우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

2009년 봄, 여름철 광양만 지역 오존의 광화학적 특성 분석 (Photochemical Analysis of Ozone Levels in the Gulf of Gwangyang in the Spring and Summer of 2009)

  • 손장호;송상근;이강웅
    • 한국대기환경학회지
    • /
    • 제26권2호
    • /
    • pp.161-176
    • /
    • 2010
  • We examined high ozone episodes observed during the intensive measurement periods (11 May~21 June and 30 July~11 August 2009) in the Gulf of Gwangyang. During that period, there were a few events (or days) in which 1 hr averaged ozone concentrations were greater than 100 ppbv. The analysis of ozone budget and photochemical characteristics related to the ozone production was carried out using a photochemical box model. Ozone sensitivity to $NO_x$ and VOCs was also examined in the study area during the measurement period. Diurnal variation of ozone during the episodes was similar to that of odd hydrogen radicals ($HO_2,CH_3O_2$, and $RO_2$), suggesting significant correlation with photochemical production of ozone during the episodes. In general, ozone concentration in the study area during the measurement period was sensitive to VOCs, whereas ozone was sensitive to $NO_x$ under certain conditions. Ozone sensitivity assessment using a radical budget analysis and $NO_x$/VOCs-control strategy was consistent with that using indicator species ($H_2O_2/HNO_3$ ratio).

The Effects of NOx Emission Reductions from Power Plants over the Eastern United States

  • Ghim, Young-Sung;Chang, Young-Soo;David G. Streets
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제15권E호
    • /
    • pp.45-54
    • /
    • 1999
  • The effectiveness of NOx emission reductions from power plants to alleviate persistent ozone nonattainment in the esterm Unites States was investigated with a focus on the Northeast Corridor, centered on New York City. The 1995 ozone episode along with the 2007 base case emission scenario was used with the Variable-Grid Urban Airshed Model(UAM-V) to determine ozone concentrations. Several scenarios based on EPA's proposal issued on October 10, 1997 were examined. Although it is widely recognized that the eastern United States includes a large Nox-sensitive region(e.g., Sillman, 1999), the study revealed that reducing NOx emissions from power plants beyond 500 miles (800km) was not effective for reducing ozone exceedances in the region. It was also found that NOx emissions from power plants play an important role in local ozone exceedances.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.

2007년 6월 수도권 오존모사 V - 배출량 변화에 따른 오존농도 예측 시 민감도기법 적용 (Ozone Simulations over the Seoul Metropolitan Area for a 2007 June Episode, Part V: Application of CMAQ-HDDM to Predict Ozone Response to Emission Change)

  • 김순태
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.772-790
    • /
    • 2011
  • In this paper, we use the HDDM (High-order Decoupled Direct Method)-driven ozone sensitivity to predict change in ozone concentrations in response to domain-wide $NO_x$(Oxides of Nitrogen) and VOC (Volatile Organic Compound) emission controls over the Seoul Metropolitan Area during June 11~19, 2007. In order to validate the applicability of HDDM to $NO_x$ and VOC control scenarios, the HDDM results are compared to Brute Force Method (BFM). For VOC controls, NME (Normalized Mean Error) between BFM and HDDM remains less than 2% until the domain-wide VOC emissions are reduced by 80%. The NME for a 40% reduction in the domain-wide $NO_x$ emissions is less than 5% but increases abruptly after further reductions in the $NO_x$ emissions (i.e., 80% reduction). The results indicates that it may be inaccurate to use ozone sensitivity coefficients estimated at a given base emission condition in predicting ozone after $NO_x$ reductions larger than ~50% of the domain total in the SMA. Therefore, HDDM application on piecewise emissions is desirable to predict ozone response to emission controls with accuracy (i.e., truck emissions rather than the domain total). For computational efficiency, HDDM shows approximately 30% faster than the BFM sensitivity approach.