• Title/Summary/Keyword: ozone consumption

Search Result 70, Processing Time 0.036 seconds

Acute Toxicity of Ozone on Survival and Physiological Conditions of Olive Flounder, Paralichthys Olivaceus (넙치(Paralichthys olivaceus)의 생존과 생리상태에 미치는 오존의 급성 독성)

  • Kim, Heung-Yun;Oh, Myung-Joo;Jung, Sung-Ju
    • Journal of fish pathology
    • /
    • v.12 no.1
    • /
    • pp.32-41
    • /
    • 1999
  • Ozonization for rearing seawater in land-based culture system has recently been utilized for disinfection of pathogenic microorganisms and improvement of water quality. This study was conducted to examine the effects of total residual oxidants (TRO) in ozone-treated seawater on survival, blood parameters, osmolality and oxygen consumption, and gill tissue of the flounder. Paralichthys olivaceus. Experiments were carried out with the starved flounder of 12~19 cm in total length at $20^{\circ}C$. The 48-hr and 96-hr $LC_{50}$ for the flounder amounts to 26.4 ppb and 22.3 ppb, respectively. With increase of TRO concentration from 24 to 39 ppb, the values of hematocrit, hemoglobin concentration, red blood cell count and osmolality of the flounder with respect to exposure time were significantly elevated, however, the oxygen consumption rates decreased. In the case of the fish exposed to 13 ppb for 96 hrs, blood glucose increased with an elapse of exposure time, while survival rate was 100%. Death apparently resulted by massive destruction of gill lamellar epithelium, severe osmotic imbalance and the lack of oxygen uptake. The results of this experiment indicated that to protect aquaculture organisms, the ozone-treated seawater should not contain any residual oxidants, and that relatively long-term exposure to TRO of low concentration can impact on survival and physiological conditions of the flounder.

  • PDF

New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

Formation of Oxidants and Removal of Dye Rhodamine B using PbO2 Electrode (PbO2 전극을 이용한 산화제 생성과 염료 Rhodaime B 제거)

  • Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.194-199
    • /
    • 2011
  • This study has been carried out to evaluate the performance of $PbO_2$ electrode for the purpose of degradation of N,N-Dimethyl-4-nitrosoaniline (RNO, indicator of OH radical), generation of ozone and decolorization of Rhodamine B (RhB) in water. The effect of the applied current (0.2~1.2 A), electrolyte type (NaCl, KCl and $Na_2SO_4$), electrolyte concentration (0.0~2.5 g/L) and solution pH (3~11) were evaluated. Experimental results showed that RhB and RNO removal were increased with the increase of current, NaCl dosage and decrease of pH. Ozone generation tendencies appeared with the almost similar to the RhB and RNO degradation, except of solution pH (Ozone generation was increased with increase of pH). Optimum current for RhB degradation and consumption of electric power was 1.0 A. The RhB degradation with Cl type electrolyte were higher than that with the sulfate type. Optimum NaCl dosage for RhB degradation was 1.0 g/L.

Pilot Study Analysis of Three Different Processes in Drinking Water Treatment

  • Kim, Dae-Ho;Lee, Byoung-Ho
    • Environmental Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, three pilot-scale plants with the capacity 30 $m^3$/day were designed and set up to treat reservoir water for the production of drinking water. Three treatment processes were compared in the pilot testing: process 1 (coagulation- flocculation- sedimentationsand filtration- ozone- BAC); process 2 (coagulation- flocculation- sedimentation- microfiltration-ozone- BAC); and process 3 (coagulation- flocculation- sedimentation- sand filtration- GAC). The quality of water has been evaluated on the basis of selected parameters such as turbidity, color, consumption of $KMnO_4$, dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), geosmin and 2-MIB. A detailed assessment of performance was carried out during a five months operation. Process 2 was found to have better removal efficiency of DOC, THMFP, geosmin and 2-MIB than process 1 and process 3 under identical conditions, although the removal rate of color was found to be the same in the three cases.

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

Economy Analysis to Retrofit Ballast Water Treatment System for an Existing Vessel (선박 평형수 처리장치 선정을 위한 경제성 분석)

  • JEE, Jae-Hoon;PARK, Sang-Kyun;OH, Cheol
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1319-1328
    • /
    • 2016
  • Since Ballast Water Management Convention has been effected, BWTS, applied to new-building vessels and existing vessels, have been developed from many countries with various treatment methods. However, BWTS is mainly typed Electrolysis, Ozone and UV type. Approximately 70 products have been type approved by the Flag Administrations. For the new-building vessels, the vessels' design and construction have been considered for arrangements and installations for BWTS. However, existing vessels which already construction had finished have problem with selection of BWTS type for installation and arrangement. The selection of the most economized BWTS system is important though, CAPEX has not been made any significant differences. However, OPEX is more important factor. Consequently, detail analysis of OPEX is the key to the selection of the most economized BWTS system and also it can be the purpose of this study. The feasibility study on the main three type of BWTS (Electrolysis, Ozone and UV type) for 175K Bulk Carrier and 57K Cargo ship has been conducted for this study. Because, these three type of BWTS have been the most frequently installed and used and the two type of object vessels are consist of the 40% of the world merchant ship market. For this study, interest rate, project duration (operation time after installation), maintenance cost and fuel oil price are considered as major factor of feasibility study. In addition, expecting Interest rates to sensitivity analysis conducted for more accurate feasibility study. For 175K Bulk carrier, ozone treatment system is more economical than other types. For 57K cargo ship, UV type is considered more economical than other types. However, it is concluded that electrolysis type is more suitable compare to installation space, total weight and electrical power consumption.

A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor - (이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 -)

  • ;Mizuki Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

Study on mold sterilization using High Electric field generation system

  • Kee-Yeon Joe
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.535-538
    • /
    • 2000
  • There are several electricity applied sterilizers such as sterilizer with high frequency sterilizer with ozone sterilizer with high voltage and so on Those sterilizers feature "because there is no chemical process there is no secondly environmental pollution" At the power conversion part ZVS and ZCS methods have been used that it results in reduced switching loss miniaturized size and lightened weight, Besides the current in the device is smaller than that of existing method. Thus it is expected that the cost of sterilization process when quality of the device is measured by power consumption will be reduced.e reduced.

  • PDF

Power Converter System for Sterilization processing Device (살균처리 장치용 전력변환장치)

  • 강욱중;고강훈;서기영;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.237-240
    • /
    • 2001
  • There are several electricity applied sterilizers such as sterilizer with high frequency, sterilizer with ozone, sterilizer with high voltage, and so on. Those sterilizers feature “because there is no chemical process, there is no secondly environmental pollution” At the power conversion part, AVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced.

  • PDF

Study on the Removal of Pharmaceuticals and Personal Care Products and Microorganism Inactivation by Ozonation (오존처리에 의한 의약품류의 제거와 미생물의 불활성화에 대한 연구 및 고찰)

  • Kim, Il-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1134-1140
    • /
    • 2010
  • Ozonation is a promising process that can effectively reduce the occurrence of micropollutants and pathogen in water. This study investigated the performance of ozonation for the removal of pharmaceuticals and personal care products (PPCPs) in secondary effluent from wastewater treatment plant. Moreover, the disinfection potential of ozonation applied for PPCPs removal was discussed. Secondary effluent filtered by sand filter was used for tested water, and ozonation was performed under 2, 4 and 6 mg/L of ozone doses. As a result, 6 mg/L of ozone dose (ozone consumption : 4.4 mg/L) was essential for the effective removal of 37 PPCPs in tested water. Several previous studies showed that the operation condition could achieve approximately 3 log inactivation of total coliform and enteroviruses. On the other hand, dissolved ozone concentration in tested water increased by 1.8 mg/L under 6 mg/L of ozone dose, probably resulting in the increase of bromate formation potential. This result implies that as alternatives to suppress the bromate formation potential during the oxidation of PPCPs by ozone, investigations on advanced oxidation processes are required.