• Title/Summary/Keyword: oxygen gas sensor

Search Result 97, Processing Time 0.024 seconds

CO sensing Properties of $SnO_{2}$ fine particles ($SnO_{2}$ 초미세 입자의 CO 감지 특성)

  • Park, Jin-Seoung;Park, Bo-Seok;Noh, Whyo-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.55-61
    • /
    • 2002
  • Ultra-fine particles of $SnO_{2}$ was synthersized by the sol-gel powder processing using tin(II) chloride dihydrate$(SnCl_{2}{\cdot}2H_{2}O)$ and ethanol$(C_{2}H_{5}OH)$ as raw materials. Gel powders can be obtained by drying of sol at $120^{\circ}C$ after aging 72hrs and 168hrs. The amount of $SnO_{2}$ phase was increased with temperature because of the evaporation of volatile components, and the creation of $SnO_{2}$ phase was almost done by the heat treatment at $700^{\circ}C/30min$ The grain sizes after firing are about 20-30nm, and it showed the narrow distribution of grain size. The specimens to measure electrical properties were fabricated by the thick film screen printing technique on the alumina substrates. The conductance of $SnO_{2}$ was increased with temperature up to $380^{\circ}C$ by the typical conduction mechanism of semiconducting ceramics. There was a region of constant conductance between about $200^{\circ}C$ and $380^{\circ}C$ due to the increment of electron concentration with temperature and the annihilation of conduction carriers by the absorption and electron trapped-ionization of oxygen on the surface of $SnO_{2}$, It was finally showed the intrinsic behaviors above $450^{\circ}C$. The sensing properties of response time, recovery, and sensitivity of CO were improved with aging time.

  • PDF

A Study on Workers' Risk-Aware Smart Bands System in Explosive Areas (폭발위험지역 근로자 위험 인지형 스마트밴드시스템에 대한 연구)

  • Lee, Byong-Kwon
    • Journal of Internet of Things and Convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2019
  • Research is underway on services and systems that provide real-time alerts for suffocating gases and potentially explosive materials, but currently smart bend type services are lacking. This study supports real-time identification of explosion hazards due to static electricity in the workplace and immediate elimination of accident occurrence factors, real-time monitoring of worker status and workplace hazards (oxygen, hazardous chemical concentration), and immediate warning and data in case of danger. We propose a method of establishing an accident prevention system through analysis. In this way, various accidents that may occur in industrial sites are monitored using IoT-based intelligent sensor nodes, wireless network technology, data processing middleware, and integrated control system, and real-time risk information at the industrial sites is prevented and accidents are prevented. By supporting a safe working environment, the company can significantly reduce costs compared to post-procurement costs.

A Comparative Study of Immersive 360-degree Virtual Cycling System and Head-mounted Virtual Cycling System for Young adults

  • Wonjae Choi;Gyugeong Hwang;Seungwon Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.187-195
    • /
    • 2024
  • Objective: Physical activity can promote physical and mental well-being. University students are more sedentary recently due to the increased use of computers and other technology. The aim of this study was to investigate differences between immersive 360-degree virtual cycling (IVC) and virtual cycling with head-mounted display (VCHMD) on aerobic capacity and usability in young adults. Design: A crossover study. Methods: Twenty-five university students (13 male, 12 female) participated in this study and completed 2 separate 30 min cycling sessions, such as IVC and VCHMD. In the IVC, participants rode on a stationary cycle while watching curved TV where recorded video was played. To enhance the sense of realism, auditory stimulation was given to the headset, and the gyroscope sensor was used to track the screen as the head moved. In the VCHMD, participants rode on the stationary cycle with head-mounted display, and other conditions were the same as IVC. Participants were assessed the aerobic capacity which included gas analyzer and portable near-infrared spectroscopy, and usability which included simulator sickness questionnaire and system usability scale. Results: Aerobic capacity was significantly difference in the IVC compared with the VCHMD except for the total hemoglobin of right and left rectus femoris and muslce oxygen saturation of left rectus femoris (p<0.05). Cybersickness was less in the IVC than VCHMD and usability was high in the IVC than VCHMD (p<0.05). Conclusions: The findings suggested that IVC might be beneficial exericse to improve aerobic capacity and has lower cybersickness and higher usability than VCHMD.

Effectiveness of Real-time Oxygen Control in Fresh Produce Container Equipped with Gas-diffusion Tube (기체확산 튜브 부착 신선 농산물 용기에서의 실시간 산소농도 제어의 효과)

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.3
    • /
    • pp.119-123
    • /
    • 2013
  • Simplified control logic was devised to fabricate and operate the modified atmosphere (MA) container of fresh produce equipped with gas-diffusion tube whose opening/closing was controlled in response to real time $O_2$ concentration. This is a simplified ramification of the previously developed control logic using both $O_2$ and $CO_2$ concentrations ([$O_2$] & [$CO_2$]). The developed logic was applied to and tested by a container system filled with spinach at $10^{\circ}C$ having optimum MA window of [$O_2$] of 7~10% and [$CO_2$] of 5~10%. It was shown that setting the proper on-off limit (11%) for $O_2$ control based on the assumed relationship $[O_2]+[CO_2]$=21% could attain the desired $CO_2$ concentration just below the upper tolerance limit ($[CO_2]_H$, 10%). The $O_2$ control point can be the lower tolerance limit or adjusted one (21-$[CO_2]_H$) depending on the commodity's MA requirement. The developed logic using single $O_2$ sensor could attain the equilibrated [$O_2$] of 11% with [$CO_2$] of 8~9% which was desired and similar to that of its predecessor ([$O_2$] of 9~10% with [$CO_2$] of 10%) using both $O_2$ and $CO_2$ sensors. Both MA containers (one only with single $O_2$ sensor control and one with $O_2$ and $CO_2$ sensors) could also keep the spinach quality without significant difference between them, but significantly better than perforated control package of air.

  • PDF

Effect of Residual Chloride Ion on Thermal Decomposition Behaviour os Stannic Acid and Physical Properties of $SnO_2$ Powder Fabricated for Gas Sensor (가스센서용 $SnO_2$분말 제조시 잔류 염소이온이 Sn수화물의 열분해거동 및 분말물성에 미치는 영향)

  • Song, Guk-Hyeon;Choe, Byeong-U;Park, Jae-Hwan;Park, Sun-Ja
    • Korean Journal of Materials Research
    • /
    • v.4 no.8
    • /
    • pp.934-944
    • /
    • 1994
  • Effects of residual chloride on thermal decomposition behaviour of a-stannic acid and physical properties of $SnO_{2}$ powder were observed. The powder was fabricated by hydroxide method; $\alpha$-stannic acid was precipitated by mixing acqueous solutions of $SnCl_{4}$ and $NH_{4}$OH . The precipitate was washed with $NH_{4}NO_{3}$ solution while washing was controlled to be of three grades to modify its residual chloride content. The precipitate was dried at $1100^{\circ}C$ ~ 24h and calcined in air at $500^{\circ}C$ ~ $1100^{\circ}C$ for one hour. Thermal decomposition behaviour of $\alpha$-stannic acid was examined by a DT-TGA and a FTIR. Chemical composition and physical properties of $SnO_{2}$ powder were observed by an AES, a BET and a TEM, respectively. With a reduction in chloride content, the relative crystallite size of $SnO_{2}$ powder slightly increased by a low-temperature-calcining. However, at a high calcining temperature(T), the reverse relation occured. It was suggested that chloride ion replaces part of lattice oxygen site of a-stannic acid. Also, chloride ion on the site was suggested to retard de-hydration as well as crystalization at a low T while to promote crystal growth of $SnO_{2}$ by forming oxygen vacancy at a high T.

  • PDF

Enhancement of PLED lifetime using thin film passivation with amorphous Mg-Zn-F

  • Kang, Byoung-Ho;Kim, Do-Eok;Kim, Jae-Hyun;Seo, Jun-Seon;Kim, Hak-Rin;Lee, Hyeong-Rag;Kwon, Dae-Hyuk;Kang, Shin-Won
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.8-11
    • /
    • 2010
  • In this study, a new thin films passivation technique using Zn with high electronegativity and $MgF_2$, a fluorine material with better optical transmittance than the sealing film materials that have thus far been reported was proposed. Targets with various ratios of $MgF_2$ to Zn (5:5, 4:6 and 3:7) were fabricated to control the amount of Zn in the passivation films. The Mg-Zn-F films were deposited onto the substrates and Zn was located in the gap between the lattices of $MgF_2$ without chemical metathesis in the Mg-Zn-F films. The thickness and optical transmittance of the deposited passivation films were approximately 200 nm and 80%, respectively. It was confirmed via electron dispersive spectroscopy (EDS) analysis that the Zn content of the film that was sputtered using a 4:6 ratio target was 9.84 wt%. The Zn contents of the films made from the 5:5 and 3:7 ratio targets were 2.07 and 5.01 wt%, respectively. The water vapor transmission rate (WVTR) was determined to be $38^{\circ}C$, RH 90-100%. The WVTR of the Mg-Zn-F film that was deposited with a 4:6 ratio target nearly reached the limit of the equipment, $1\times10^{-3}\;gm^2{\cdot}day$. As the Zn portion increased, the packing density also increased, and it was found that the passivation films effectively prevented the permeation by either oxygen or water vapor. To measure the characteristics of gas barrier, the film was applied to the emitting device to evaluate their lifetime. The lifetime of the applied device with passivation was increased to 25 times that of the PLED device, which was non-passivated.

The Application of Octa-Substituted Metallophthalocyanine Langmuir-Blodgett films for $NO_2$ Measurement (수정진동자를 이용한 프탈로시아닌 LB박막의 $NO_2$ 감지 특성)

  • Kwon, H.J.;Lee, Y.J.;Chang, Y.K.;Kim, J.D.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.254-262
    • /
    • 1998
  • Multilayer Langmuir-Blodgett (LB) films coated on quartz crystal microbalance (QCM) of octa-substituted metallophhtalocyanines ($MPc(OEH)_8$, M = Cu, Co, and Sn) and dihydrogen phthalocyanines ($H_2Pc(OEH)_8$) were used to quantify $NO_2$ concentrations. They were exposed to various concentrations of $NO_2$ in dry $N_2$. Among the four phthalocyanines we tested, the metal-free $H_2Pc(OEH)_8$ was observed to be most sensitive to $NO_2$. However, its LB film showed a partially irreversible behavior, that is part of the frequency change due to $NO_2$ adsorption could not be recovered even after purging with pure $N_2$ gas for an extended period. Examining the spectra of NMR and FTIR revealed fact that the irreversible portion of frequency change was due to ether groups in the linkage between side chains and the Pc unit. In order to remove the effect of such initial deactivation, on $NO_2$ quantification experiment, a freshly fabricated LB film was treated at a high concentration of $NO_2$ so that the ether sites were saturated. A pretreated LB film showed a reproducible performance for repeated uses. The $CuPc(OEH)_8$ LB film showed a satisfactory sensing performance down to as low as 4 ppm. For the $H_2Pc(OEH)_8$ LB film, the lower detection limit was found to be 35ppb of $NO_2$. In order to make the experimental condition more realistic, the carrier gas, dry nitrogen, was replaced by air. It was observed that the presence of oxygen, a weak electron acceptor, reduced the sensitivity and thus increased the sensing limit to hundreds of ppb. Results of experiments with moisture added showed that the interference of moisture was quite severe.

  • PDF