• Title/Summary/Keyword: over-current

Search Result 5,987, Processing Time 0.032 seconds

Steady-State Characteristics of Resonant Switched Capacitor Converters

  • Shoyama Masahito;Deriha Fumitoshi;Ninomiya Tamotsu
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.206-211
    • /
    • 2005
  • Conventional switched capacitor converters have an inherent drawback that their efficiency decreases as the output current increases. This inherent drawback is due to a periodical forced charging and discharging operation in the internal switched capacitors accompanied by a large capacitor current. Their efficiency can not be increased by decreasing its internal resistance. As a result, conventional switched capacitor converters have been limited to uses with a very small output current. To solve this problem we presented a novel switched capacitor converter topology that uses a resonant operation instead of the forced charging and discharging operation. Its advantage over a conventional switched capacitor converter is higher efficiency even in a high output current region. In this paper, the operation analysis and steady-state characteristics are described in detail for a half buck type switched capacitor converter, and they are confirmed by experimentation.

A study on the high-power Sepic converter for high-power-factor, low current harmonics using PWM control (PWM 제어를 이용한 고역율, 저교조파형 고출력 Sepic 컨버터에 관한 연구)

  • Joo, Hyong-Jong;Kwon, Myung-Ill;Jang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1211-1213
    • /
    • 2003
  • A pulse width modulation(PWM) method for single-phase Sepic-type rectifier is introduced in this paper. The characteristics of the proposed PWM system are high performance high power factor with low input current harmonic distortion. The proposed control method is based on the average-current-mode using the dedicated integrated circuit UC3854 this technique it is possible to implement a very simple control circuit for unitary power-factor in CCM operation and also to provide over-current protection.

  • PDF

Design of convection current circulation system in reservoir using CFD simulation (CFD모사를 이용한 저수지 물순환장치 유동 설계)

  • Lee, Yosang
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.133-142
    • /
    • 2012
  • Convection Current Circulation System(CCCS) in stratified reservoir controls development of anaerobic condition and algal bloom during summer. In order to increase the CCCS effectiveness, we analyze diverse design parameters to make optimize the flow pattern in reservoir. In this study, we interpret the internal flow with installation and operation condition of CCCS based on CFD in reservoir. Design variables of CCCS is reservoir depth, stratification strength, distance of between CCCS and so on. Since reservoir depth and stratification strength in variables is depending on natural phenomenon, we evaluated current circulation effect by distance of CCCS and proposed the optimal design condition using CFD simulation. Flow and diffusion changes in water body was assessed by temperature and dye test. Changes in water floor temperature at 40m intervals was slowly descending over 37 hours. Dye diffusion simulation at 60m intervals, the radius of the spread between two devices were overlapped after 12 hours.

Efficiency Optimization Control for Energy Saving of Synchronous Reluctance Motor (동기 리럭턴스 전동기의 에너지 절감을 위한 효율 최적화 제어)

  • Lee Jung-Chul;Lee Hong-Gun;Chung Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.159-162
    • /
    • 2001
  • This paper is proposed an efficiency optimization operation algorithm for synchronous reluctance motor (SynRM) using current phase angle control technique. The SynRM has to controlled with the optimal current phase angles with load and operation speed variation, to obtain high efficiency over the wide speed ranges. An efficiency optimization condition in SynRM which minimizes the copper and iron losses is derived based on the equivalent circuit model of the machine. The objective of the efficiency optimization control algorithm compensating the optimum current angle, is to seek a combination of d and q-axis current components which provides minimum losses at a certain operating point in steady state. The usefulness of the proposed efficiency optimization control is verified through vector-controlled inverter system with the SynRM.

  • PDF

A Driving Torque Prediction of Brushless DC Motor by Using the Measured Current Data (전류측정 데이터를 이용한 브러쉬 없는 직류전동기의 구동토크 예측)

  • 변영철;전혁수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.242-250
    • /
    • 1999
  • This paper presents an estimation scheme of the external torque applied on the motor by using measured motor input current when the IPM(Interior Permanent Magnet) rotor type BLDC motor operates with constant speed. In general, the BLDC motor is controlled by vector control method. If it could be operated at over critical speed, the control scheme must be modified to flux-weakening control method. The external torque applied on the motor using flux-weakening control method could not be calculated by conventional torque equation because the demagnetizing current Id exists in the motor input current. In this paper, the commonly used flux-weakening control method is studied and the modified torque estimation scheme is suggested. The estimation scheme has been verified by the simulations and experimental results.

  • PDF

A Novel Hybrid Fault Location Sensor Employable to the Power Transmission Systems (가공 송전선의 사고 및 낙뢰 검출을 위한 새로운 하이브리드 센서)

  • Chang, Yong-Moo;Kang, Moo-Sung;Hwang, Ryul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.583-584
    • /
    • 2005
  • In this work, a novel hybrid FL sensor consisting of two Rogowski coils has been designed for the installation on the ground wire of the transmission tower. The operation range of these coils is as follows: 30kA for the fault current comingfrom the ground fault or short-circuit and for the lightning current up to 150kA over 500kHz. Thus, two important functions could be provided: one is to detect the fault current and the other one is to find the fault location between towers or the location of induced lightning stroke. The on-site investigation at 800kV test yard has been under progress for its on-site application.

  • PDF

Design Method and Analysis for Current Limit Charger of Battery System for Regulating CDE Power of Satellite

  • Kim, Kyudong
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.74-78
    • /
    • 2020
  • The cooler driver electronics (CDE) for maintaining a low temperature of a satellite payload IR sensor has a compressor with a pulsation current load when in operation. This pulsation current creates a large voltage fluctuation and may negatively affect both the load and regulated bus stability. Thus, a CDE power conditioning system has a battery for use as a buffer that is connected in front of the CDE load line. In this system, a battery charger limiter circuit is required to protect from an over-charge of the battery and power to the load. In this study, an optimal design and parameter selection were developed and simulated.

Current concept of the surgery-first orthognathic approach

  • Choi, Jong-Woo;Lee, Jang-Yeol
    • Archives of Plastic Surgery
    • /
    • v.48 no.2
    • /
    • pp.199-207
    • /
    • 2021
  • Traditional orthognathic surgery has long been performed after presurgical orthodontic treatment. Despite some concerns, the surgery-first orthognathic approach (SFOA) or surgery-first approach (SFA) without presurgical orthodontic treatment has gradually gained popularity. In recent years, several articles dealing with the concepts of the SFA have been published worldwide. However, the SFA has not yet been standardized, and many surgeons use slightly different protocols and concepts. This review article discusses the beginning and evolution of the SFA and its current concepts, including some opinions based on the authors' clinical experiences over the last 15 years. According to recent investigations, the SFA could be applied effectively in several situations including class III malocclusion, class II malocclusion, and facial asymmetry. However, debate on the SFA continues and many issues remain to be resolved. This review article addresses the current issues regarding the SFOA, including its advantages and disadvantages, as well as its indications and contraindications. The authors summarize various aspects of the SFA and expect that this review article will help surgeons and orthodontists better understand the current status of the SFA.

Tool Breakage Detection using Pattern Characteristics of Feed Motor Current in Milling Operations (이송모터 전류신호의 패턴특성을 이용한 밀링공구의 파손검출)

  • KIM, Sun-ho;Ahn, Jung-hwan;Park, Hwa-young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.2
    • /
    • pp.23-34
    • /
    • 1995
  • This paper is concerned with effective and reliable tool breakage detection method using pattern characteristics of feed motor current in milling operations. Correlation coefficient is derived from the feature vector of signal for two consecutive which are extracted feed motor current over three spindle revolutions. The changing pattern of correlation coefficient is continuously compared to detect tool breakage and monitor cutting conditions. This proposed monitoring scheme is not affected by different tools, friction of motion, and varying cutting conditions and material shapes. Experimental results are presented to support the proposed monitoring scheme.

  • PDF

A Design of Novel Class-A bipolar $CCII{\pm}$ and Its Application to output Current Controllable CCII+ (새로운 A급 바이폴라 $CCII{\pm}$와 이를 이용한 출력 전류 제어 가능한 CCII+ 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.11
    • /
    • pp.48-56
    • /
    • 2011
  • Novel class-A bipolar current conveyor($CCII{\pm}$) with differential current output and its application to output current controllable CCII+ for electronic tuning systems are designed. The $CCII{\pm}$ is consists of conventional CCII+ and complementary cross current sources. The CCII+ with controllable the output current consists of the $CCII{\pm}$ and a current gain amplifier with single-ended current output. The simulation result shows that the $CCII{\pm}$ has current input impedance of $1.9{\Omega}$ and a good linearity for voltage and current follower. The proposed CCII+ has 3-dB cutoff frequency of 10MHz for the range over bias control current $100{\mu}A$ to 10mA. The range of output current control is four decade. The power dissipation of the CCII+ is 4.5mW at supply voltage of ${\pm}2.5V$.