• Title/Summary/Keyword: over-current

Search Result 5,933, Processing Time 0.039 seconds

Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water (전기분해수 살균효과 및 소독부산물 생성 특성 평가)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

A Numerical Study of Rip Current Generation Modulated with Tidal Elevations at the Daecheon Beach (큰 조차에 따라 변화하는 지형의 대천 해수욕장 이안류 발생 특성 수치모의 연구)

  • Junwoo, Choi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.6
    • /
    • pp.247-257
    • /
    • 2022
  • In order to investigate the generations of rip currents modulated with the tidal elevations at a mega-tidal beach at the West Sea coast, numerical simulations of rip currents over the topography of the Daecheon beach were performed by using a Boussinesq-type wave and current model, FUNWAVE. The mega-tidal coast includes rocky outcrops (i.e., reefs) lying over or under the water surface according to the tidal elevations in the offshore and nearshore bathymetry. The offshore topographically-controlled rip currents were well reproduced due to the alongshore non-uniformities transformed by the tide-modulated topography. This study addressed the generation types of rip currents to occur at the mega-tidal coast with the tide-modulated outcrops and reefs.

Mathematical Model for Mean Transfer Delay of Web Object in Initial Slow Start Phase (초기 슬로우 스타트 구간에서 웹 객체의 평균 전송 시간 추정을 위한 수학적 모델)

  • Lee, Yong-Jin
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.248-258
    • /
    • 2008
  • Current Internet uses HTTP (Hyper Text Transfer Protocol) as an application layer protocol and TCP (Transmission Control Protocol) as a transport layer protocol to provide web service. SCTP (Stream Control Transmission Protocol) is a recently proposed transport protocol with very similar congestion control mechanisms as TCP, except the initial congestion window during the slow start phase. In this paper, we present a mathematical model of object transfer latency during the slow start phase for HTTP over SCTP and compare with the latency of HTTP over TCP. Validation of the model using experimental result shows that the mean object transfer latency for HTTP over SCTP during the slow start phase is less than that for HTTP over TCP by 11%.

Evaluation of Low Power and High Speed CMOS Current Comparators

  • Rahman, Labonnah Farzana;Reaz, Mamun Bin Ibne;Marufuzzaman, Mohammad;Mashur, Mujahidun Bin;Badal, Md. Torikul Islam
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.317-328
    • /
    • 2016
  • Over the past few decades, CMOS current comparators have been used in a wide range of applications, including analogue circuits, MVL (multiple-valued logic) circuits, and various electronic products. A current comparator is generally used in an ADC (analog-to-digital) converter of sensors and similar devices, and several techniques and approaches have been implemented to design the current comparator to improve performance. To this end, this paper presents a bibliographical survey of recently-published research on different current comparator topologies for low-power and high-speed applications. Moreover, several aspects of the CMOS current comparator are discussed regarding the design implementation, parameters, and performance comparison in terms of the power dissipation and operational speed. This review will serve as a comparative study and reference for researchers working on CMOS current comparators in low-power and high-speed applications.

Current Differential Relaying Algorithm for Power Transformer Protection Operating in Conjunction with a CT Compensating Algorithm (보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식)

  • Kang, Yang-Cheol;Park, Jong-Min;Lee, Mi-Sun;Jang, Sung-Il;Kim, Yong-Gyun;So, Soon-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1873-1878
    • /
    • 2007
  • Current differential relays may maloperate during magnetic inrush and over-excitation because a significant differential current is produced. To prevent maloperation, the relays adopt some harmonic components included in the differential current. The harmonic restraints may increase the security of a relay but cause the operating time delay of a relay when an internal fault occurs. Moreover, the operating time delay is more increased if a current transformer (CT) is saturated. This paper describes a current differential relaying algorithm for power transformer protection with a compensating algorithm for the secondary current of a CT. The comparative study was conducted with and without the compensating algorithm. The performance of the proposed algorithm was investigated when the measurement CT (C400) and the protection CT (C400) are used. The proposed algorithm can compensate the distorted current of a CT and thus reduce the operating time delay of the relay significantly for an internal fault with CT saturation.

Design of a Wind Tunnel for Plug Seedlings Production under Artificial Light and Aerodynamic Characteristics above Plug Stand (인공광하의 공정육묘용 풍동 설계 및 공정묘 개체군상의 공기역학적 특성)

  • 김용현;고재풍수
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.429-435
    • /
    • 1996
  • A wind tunnel consisting of two air flow conditioners with polycarbonate pipes, a plant growth room, a suction fan and fan controller, and fluorescent lamps, was designed to investigate the interactions between the growth of plug seedlings under artificial light and their Physical environments. Light transmissivities in the plant growth room based on the photosynthetic photon flux density and photosynthetically active radiation was appeared to be 96.3% and 96.8%, respectively. Measurement showed a uniformity in the vertical profiles of air current speed at the middle and rear regions of plug trays in wind tunnel. This result indicated that the development of a wind tunnel based on the design criteria of the American Society of Mechanical Engineers was adequate. Air current speed inside the plug stand was significantly decreased due to the resistance by the leaves of plug seedlings and boundary layer developed over and below the plug stand. Driving force to facilitate the diffusion of gas inside the plug stand might be regarded as extremely low. Aerodynamic characteristics above the plug stand under artificial light were investigated. As the air current speed increased, zero plane displacement decreased but roughness length and frictional velocity increased. Zero plane displacement linearly increased with the average height of plug seedlings. The wind tunnel developed in this study would be useful to investigate the effects of air current speed on the microclimate over and inside the plug stand and to collect basic data for a large-scale plug production under artificial light in a semi-closed ecosystem.

  • PDF

Design on Algorithm of Power Control Unit for Charging Satellite Battery (위성 배터리 충전을 위한 전력제어유닛의 알고리즘 설계)

  • Park, JeongEon;Lee, Byoung-Hee
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.95-99
    • /
    • 2017
  • The lifetime of a battery that supplies all the power required by a satellite in the eclipse is directly related to the lifetime of the satellite. Because the lifetime of the battery is influenced by the charging method of the battery, the power control unit that controls the charging of the battery should be designed in consideration of battery life. The battery charging is performed by controlling the charge current in the power control unit generated from the solar cell in the daytime. In order to prevent overcharge of the battery and for considering frequency of eclipse in each season, parameters related battery charging should be designed differently according to the season and to prevent over-current charging and over-voltage charging during charging, charge current is controlled by monitoring battery charge / discharge status, charge current amount, battery voltage, battery capacity, battery temperature and battery cell voltage. In satellite, tapering method is used to control charge current by reflecting each condition. In this paper, design battery charging algorithm of satellite power control unit using tapering charging method. convert the designed algorithm into a code that can be uploaded to satellites and verify the operation through testing in the established satellite environment.

The Impact of Corporate's Attributes on Corporate Pension Insurance Products & Type Preference (한국 기업 속성에 따른 기업연금보험 상품 및 제도유형 선호도 분석)

  • Joo, Heon
    • The Journal of Industrial Distribution & Business
    • /
    • v.8 no.2
    • /
    • pp.21-31
    • /
    • 2017
  • Purpose - The total amount of advanced Corporate Pension Insurance products exceed 148 trillion Korean Won at the end of 2016. For a firm with over 300 employees, when a bill on compulsion of introduction of Corporate Pension Insurance products, currently pending in court, is passed, Corporate Pension shall be an essential. The findings of the paper will provide a guideline for understanding on firm's attributes and its effects towards introduction of Corporate Pension Insurance products. Research design, data, and methodology - The data were collected using statistics of employer panel survey from Korea Labour Institute in 2013. The study analyses a sample survey on 1,775 outstanding enterprises and their HR department among whole corporations in Korea. For analysis of data, empirical testing by Logistic Regression was utilized. Results - As an outcome of empirical testing, variables on share of regular employees and the aged employees in over 50's generates a significant statistical meaning. It eventually gives a great impact on purchase of Corporate Pension scheme. Moreover, variables on corporate financial statement, current sales, current net income, total amount of the debts, labor cost per person also has a vital influence on introduction of Corporate Pension Insurance products. Lastly, variables on firm's labor relationship have no effect except for the execution or non-execution of HR consulting. Meanwhile, Variables affecting a choice on pension schemes types among firm's attributes are a share of regular employees, current net income, execution or non-execution of HR consulting etc. These variables represents a statistical implication. According to their each features, they prefer DB or DC plan. Conclusions - Introduction of corporate pension scheme is apposite to contemporary Korea's situation entering a hyper-aging society and firms with a high share of regular employees, the weight of aging, current sales, current net income and labor cost per person are exceedingly active in purchasing Corporate Pension Insurance products. However, after the introduction of corporate pension scheme, firms which has an implementation of consultation on human resource management, flexible benefits plan, job security and welfare system prefer DC plan whereas from financial perspective firms with high net income prefer DB plan.

Spectrum Measurement Study of Arc Plasma on Triggered Vacuum Switch (TVS) (TVS에서 아크 플라즈마의 분광 측정 연구)

  • Nam, S.H.;Han, Y.J.;Lee, B.J.;Kim, S.H.;Park, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1732-1734
    • /
    • 2001
  • The purpose of this experiment was to develope Triggered Vacuum Switch(TVS) and to improve understanding of the high current vacuum arc phenomena in the TVS. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. Breakdown of the TVS produced high current vacuum arc plasma. A spectroscopic measurement was performed over 20 kA peak current in the center of electrodes, in the vicinity of cathode, and outside electrodes. The electrode material tested was Fe. Measured Fe spectrum range was from 200 nm to 900 nm. Measurement result showed that over 90 percent of the charge states were FeII and the others were FeI and FeIII. The electron temperature was determined from the relative line intensity ratio methode of FeII system by assuming the local thermal equilibrium(LTE). The electron temperature at the center of electrodes was measured as 1.5 eV at 26 kA peak current. The electron temperature varied with its peak current. Intensity of spectrums is the highest in the vicinity of the cathode. Further we will also present study result of the diode phenomena in the TVS.

  • PDF