• 제목/요약/키워드: over-current

검색결과 5,914건 처리시간 0.039초

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.

Estimation of Delta Winding Current and Its Application to a Compensated-Current-Differential Relay for a Y-Δ Transformer

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, En-Shu
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.255-263
    • /
    • 2010
  • The compensated-current-differential relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Delta winding current is necessary to obtain the modified differential current for a $Y-\Delta$ transformer. This paper describes an estimation algorithm of the delta winding current and its application to a compensated-current-differential relay for a $Y-\Delta$ transformer. Prior to saturation, the core-loss current is calculated and used to modify the differential current. When the core first enters saturation, the initial value of the core flux is obtained by inserting the modified differential current into the magnetization curve. This flux value is used to derive the magnetizing current and consequently the modified differential current. The operating performance of the proposed relay was compared against a conventional current differential relay with harmonic blocking. Test results indicate that the proposed relay remained stable during severe magnetic inrush and over-excitation, and its operating time is significantly faster than a conventional relay. The relay is unaffected by the level of remanent flux and does not require an additional restraining or blocking signal to maintain stability. This paper concludes by implementing the proposed algorithm into a prototype relay based on a digital signal processor.

플라즈마중합 PPMMA의 전기전도 기구에 관한 연구 (The study on electrical conduction mechanism of plasma-polymerized methyl methacrylate (PPMMA))

  • 박재윤;박광현;한상욱;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.283-285
    • /
    • 1987
  • Transient conduction current (I - t characteristics) were measured in thin PPMMA (plasma-polymerized methyl methacrylate) films over the temperature range $60^{\circ}C-140^{\circ}C$ and the applied voltage range 3V - 30V. The current, which increased with temperature rise at constant applied voltage, showed less absorption current (current decay with time) at higher temperature region compared with those at lower temperature region. And the current, which increased with applied voltage rise at the constant temperature, showed less absorption current at higher voltage compared with those at lower voltage. The electric field current density characteristic curves were abtained from the conduction current values were after applying voltage for 30 minutes. And transient conduction currents were analyzed with high field conduction theories.

  • PDF

직류고속도차단기의 소전류 차단 특성연구 (The Characteristic Study for Small Current Breaking of High Speed DC Circuit Breaker)

  • 민병훈;장우진;고인석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권8호
    • /
    • pp.396-402
    • /
    • 2006
  • Even the case DC circuit Breaker have good quality for interruption of high current like heavy load current, short-circuit current, the verification for small current breaking capability of circuit breaker should be performed. It comes from the reason DC small current breaking failure can be lead to break out second heavy fault condition and in the long run substation shutdown. In this paper, we can find the characteristics of DC small current and international test standard discription about small current breaking and one of the proper solution to get over it.

Flexible Rogowski 코일을 이용한 클램프형 전류 센서의 개발 (Development of Clamp Current Meter using a Flexible Rogowski Coil)

  • 장용무;김성일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.472-475
    • /
    • 2002
  • A Rogowski coil can measure alternating currents from a few amps to over 1 million amps in a frequency range from less than 0.1 Hz to about lMhz. A Rogowski coil provides an induced output voltage which is proportional to the rate of change of the primary current enclosed by the flexible or the rigid coil-loop. Therefore, it is necessary to integrate the output voltage in order to produce a voltage proportional to the current. Also. it can reproduce the current waveform on an oscilloscope or any type of data acquisition device. This paper describes the practical design of the combination of a Rogowski coil and an integrator which provides a versatile current measuring system to accommodate a wide range of frequencies, current levels and conductor sizes.

  • PDF

차전류 차분 블로킹 변압기 보호용 전류차동 계전기 (A Current Differential Relay for Transformer Protection with a Blocking Method Using the Difference-Function of a Differential Current)

  • 강용철;원성호;김대성;양성채
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.691-697
    • /
    • 2003
  • This paper proposes a current differential relay for transformer protection that operates in accordance with a blocking method based on the difference-function of a differential current. For magnetic inrush and over-excitation, discontinuities in the first-difference function of the differential current arise at the points of inflection, which correspond to the start and end of each saturation period of the core. These discontinuities are converted into the pulses in the second- and third-difference functions of the differential current. The magnitudes of the pulses are large enough to detect saturation of the core. A blocking signal is issued if the magnitude of the third-difference function exceeds the threshold and is maintained for three quarters of a cycle. The performance of the relay is assessed under various conditions with magnetic inrush, internal faults and external faults. The proposed blocking method can improve significantly the operating time of a relay and achieve high sensitivity of a relay.

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF

넓은 온도 범위에서 고정 구동전류로 동작하는 1.25 Gbps 850 nm 산화형 VCSEL 송신기의 특성 (Characteristics of an 1.25 Gbps 850 nm Oxide VCSEL Transmitter Operating at Fixed Current over a Wide Temperature Range)

  • 김태기;김태용;김상배;김성한
    • 대한전자공학회논문지SD
    • /
    • 제44권12호
    • /
    • pp.43-53
    • /
    • 2007
  • 넓은 온도 범위에서 고정된 구동 전류로 동작하는 VCSEL(Vertical-Cavity Surface-Emitting Laser) 송신기의 저전류 동작 특성을 살펴보았다. 사용된 VCSEL은 산화형 850 nm 레이서로, $d^2I_{th}/dT^2$값이 약 $1.346\times10^{-4}mA/^{\circ}C^2$으로 문턱전류의 온도의 존성이 비교적 낮은 것이었으며, 데이터 속도는 1.25 Gbps였다. 칩 상태에서의 광출력-전류-전압을 측정하여 $20^{\circ}C$에서의 광출력이 1 mW가 되는 전류를 on 전류로 설정한 후 $-20^{\circ}C$에서 $80^{\circ}C$의 온도 범위에서 $20^{\circ}C$ 간격으로 온도를 바꾸어가며 off 전류의 변화에 따른 turn-on 특성, turn-off 특성 그리고 eye-diagram을 관찰하였고 온도와 off 전류에 따라 eye-diagram에서 rise time, fall time, extinction ratio, timing jitter가 어떻게 변화하는지를 살펴보았다. 그 결과 최소 문턱전류보다 약 $0.1\sim0.2mA$ 정도 낮게 off 전류를 설정하면 $-20^{\circ}C$에서 $80^{\circ}C$의 온도 범위에서 off 전류와 on 전류를 변화시키지 않고 1.25 Gbps에서 송신기로 동작 시킬 수 있음을 확인하였다.