• Title/Summary/Keyword: over current

Search Result 5,952, Processing Time 0.036 seconds

A Study on The Diagnosis of Broken Rotor Bars in Three Phase Squirrel-Case Induction Motor (3상 농형 유도전동기 회전자 바의 고장진단에 관한 연구)

  • Kim, K.W.;Kwon, J.L.;Lee, K.J.;Kim, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.635-637
    • /
    • 2001
  • The faults of the squirrel cage induction motor is grew increasingly complex as the faults resulting in the shorting of a stator winding and the broken rotor bar or cracked rotor end ring, bearing faults, and so on. The users of electrical machines initially relied on simple protections such as over-current, over-voltage, earth-fault, etc. to ensure safe and reliable operation. but this method cause heavy financial losses and the threat of safety therefore it has now become very important to diagnose faults at there very inception. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF

Distributed generation protection technique to minimize the outage section (정전구간 최소화를 위한 분산전원 보호)

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, Enshu;Hwang, Tae-Keun;Lee, Ji-Hoon;Cha, Sun-Hee;Park, Jong-Min;Zheng, Tai-Ying
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.450-452
    • /
    • 2005
  • Distributed generation (DG) plays an important role in the power system nowadays. Over-current relay, widely used in the DG protection, causes a wide outage section and long time delay. This paper proposes a DG protection technique to minimize the outage section. The proposed method uses three directional over-current relays with time delay, which are connected to the point of common coupling. The method can minimize the outage section.

  • PDF

Time Delay Limit of Over Current Relay for Maintaining Stability in Industrial Power Systems (산업용 전력계통의 안정도 유지를 위한 과전류계전기의 시간지연 한계)

  • Kim, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.190-192
    • /
    • 2002
  • The industrial power distribution system is a radial system and therefore usually protected with time delayed over current relays (OCR's). Proper time dial settings are provided at the OCR's. Meanwhile, the systems, where synchronous generator, or synchronous motors, or large induction motors are operating, can not be protected with only OCR's with time grading. This paper presents a technical limit and a suitable range of time delay in applying OCR's to clearing faults in the industrial power systems for maintaining stability. Dynamic simulations are made to show them employing a real power systems of a large petro-chemical complex.

  • PDF

A Study on DC Circuit Breaker using SCR Chung Hoo Park (SCR 에 의한 직류회로차단기의 과부하차단특성개선)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF

Design of Fast and Overshoot Free Digital Current Controller (오버슈트 없는 고속 디지털 전류제어기 설계)

  • 이진우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.163-169
    • /
    • 2000
  • From the viewpoint of the cost effective design of power conversion systems, it is very important to fully u utilize the CillTent capacity of power devices over all circumstances. Therefore this paper deals with the l practical design of digital CillTent controller to meet the requirements of fast and overshoot free control r response over the varying control voltage bOlmds, the accompanied computational delay, and the system U W1certainties. The proposed controller consists of high gain PI control schemes using both the conditional i integrator and the modified delay compensator. The simulation and experimental results show the validity of t the proposed controller.

  • PDF

A Study on communication method between OverCurrent Relay Agents using DNP 3.0 (DNP3.0을 이용한 과전류 계전기 에이전트의 통신 방안 연구)

  • Lee, H.W.;Jung, K.H.;Lim, S.I.;Hyun, S.H.;Choi, M.S.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.265-267
    • /
    • 2002
  • In this paper, the communication between Over-Current Relay agents is realized using DNP(Distributed Network Protocol), which is the standard communication protocol of distribution automation system in KEPKO. The key words in OCR agent communication are defined and represented by use of DNP application function code. And the DNP index for OCR agent is defined. The proposed communication scheme is tested by use of Communication Test Harness, a test tool for DNP protocol to show its soundness.

  • PDF

Current status on pesticide residues in commercial agricultural commodities in Seoul area (서울시내 유통 농산물에서의 농약잔류 실태)

  • 한선희
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.49-53
    • /
    • 2003
  • Through the five years analysis of monitoring data on pesticide residues from 1998 to 2002, current status on pesticide residues on commercial agricultural products in Seoul area was evaluated. The rate of over maximum residue limits(MRLs) has been decreased into 5.8% in 1998, 2.5% in 1999, 1.6% in 2000, 1.4% in 2001, and 1.5% in 2002 gradually, where as total sample numbers analyzed increased 1,300 in 1998, 4,200 in 1999, 5740 in 2000, 6,160 in 2001, and 5,440 in 2002 annually, The pesticide which frequently detected in samples were endosulfan, procymidone, chlorotalonil, vinclozolin, and chlorpyriphos and pesticide found over MRLs were procymidone, vinclozolin, endosulfan and etc.

  • PDF

Analysis of Transient State in the Superconducting distribution Cable Systems (초전도 배전 케이블 계통에서의 과도상태 해석)

  • Kim, Nam-Yoel;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.555-557
    • /
    • 2003
  • As electric power transmission systems grow to supply the increasing electric power demand, transmission capacity is larger. but that's really difficult to secure the location for power transmission and distribution to user. The high temperature superconducting(HTS) cable is a method to solve this problem. But for applying to real systems, it needs to investigate the effect of HTS cable. The most important things is the investigation of fault condition. the fault on HTS cable include the quench state. When a fault occur in a circuit, three critical parameters(temperature, current density, magnetic field) exist. when one of these parameters exceeds the critical value, the superconducting becomes normal-conducting. f the cooling power is insufficient to recover the superconducting state, the normal-conducting zone expands. In order to solve these problem, this paper present simulate the quench state considering the over-current and over-voltage in the informal circuit and analyze the quench state.

  • PDF

Fault Detection of Power Systems Using Fuzzy Pattern Classification (퍼지 패턴분류를 이용한 전력개통에서의 고장검출)

  • Kim, Hee-Soo;Ko, Jae-Ho;Bang, Sung-Yun;Yim, Hwa-Yeoung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1203-1205
    • /
    • 1998
  • Fault Detection of power system must be rapid and precise over input signal without relation to any disturbance. But, it is difficult to detect current unbalance, over voltage, and underfrequency for digital relay comparison of fault perfectly. In this paper, we measure each phase current and infer type of fault using fuzzy pattern classification.

  • PDF

Research about performance improvement intelligence of over current protection relay (과전류보호계전기의 지능화 성능개선에 관한 연구)

  • Park, Chan-Won;Jeon, Chan-Min;Chun, Sam-Sug;Kim, Dong-Ju;Kim, Jeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2319-2321
    • /
    • 2003
  • 본 연구에서는 전력계통에서 배전반 자동화 장치중 하나인 ACB(air circuit breaker) controller로 사용되는 OCR(Over Current Protection Relay)의 지능화와 성능개선을 모색하고자 한다. 개발된 이 장치는 전력계통에서 전류의 흐름을 지능화 알고리즘으로 감시하여 최적으로 사고를 방지할 수 있으며, 대화형의 다양한 기능과 통신기능을 내장하고 있어 원격제어 및 관리가 가능하는 특징을 포함한다.

  • PDF