• 제목/요약/키워드: outside wall

검색결과 353건 처리시간 0.023초

Mock-up Model of the Environment Assessment Study on Red-clay and Cement (Mock-up모델을 이용한 황토 및 시멘트의 환경요소 평가 연구)

  • Choi, Yool;Song, Hyeun-Guen
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study is to measure the environmental effects of different alternative building materials. The following building materials were tested: clay bricks, cement wall, and red-clay plaster. Four mock-up models were constructed using clay bricks, cement wall, red-clay plaster and the last model as the control model. The effects of the above four building materials on temperature, humidity, the emissions of formaldehyde, and V.O.C were measured. This experiment was conducted during September. The conclusions are as follows. Clay bricks were able to control temperature, humidity and filter formaldehyde by itself. The environment within the cement wall was not affected by the humidity changes outside. Red-clay plaster walls had little impact on the environment because it is very thin.!

Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks (석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구)

  • Kim, Hong;Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

Structural Health Monitoring of Nuclear Containment Building Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 원자력발전소 격납건물의 구조 건전성 계측)

  • Lee, Seung-Hwan;Lee, Nam-Kwon;Lee, Geum-Seok;Lee, Hong-Pyo;Yu, Yun-Sik
    • Journal of Sensor Science and Technology
    • /
    • 제22권1호
    • /
    • pp.71-75
    • /
    • 2013
  • Nuclear containment building is used as second blockage to protect us from a radiation leakage caused by the natural disaster or any accidents, so it's safety is important and must be kept with continuous surveillance. In this study, we measured the strain of a nuclear containment building's wall by using FBG sensor and investigated the structural safety of a nuclear containment building. 50 FBG strain sensors and 18 FBG strain sensors were attached on the side wall and upper dome of a nuclear containment building, respectively. We measured the strains of the outside concrete wall during the Structural Integrity Test (SIT) of a nuclear containment building. The strain of an upper dome was larger than that of a side wall, about $200{\mu}{\varepsilon}$. And the very small strain was measured at vertical direction of a side wall. These experimental results were used to evaluate the structural health of nuclear containment building.

A study on the application of BIPV to the Apartment Building (BIPV의 아파트 건물 적용 가능성에 대한 연구)

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.25-32
    • /
    • 2006
  • Regarding to the Domestic housing politics to improve residing environment and effective use of country land, apartment buildings have been constructed since early of 1970s. Now apartment is taking over 50% out of entire housing in Korea. In the view point of PV application to the apartment, PV has amny advantages because of the wideness of out-walls and high floors building in APT. Therefore, if APT could use the electricity produced by BIPV, we can solve more easily environment and energy problems caused by housing. The research conclusion by analysing conditions and application method to introduce BIPV application to APT in near future is as below. -The out look of APT has been developed periodically and recently gable roof or canopy is popular which PV installation is more favorable. -For Balcony part with double skin facade sassy window, It has a preferable condition to install on the wall depending on the window direction. -In case of shorter distance between buildings due to high ratio of outside measurement, it is more desirable to install PV on the roof than on the wall of Apartment by considering low solar altitude. -Also depending on the direction of APT building, it is more effective and productive in electricity in the broad surface of side wall of APT. -In case of superhigh floor APT where facade system is mostly double skin facade of curtain wall system, PV module can replace the traditional curtain wall and will reduce architectural materials and obtain various out look design thereof.

Eco-Moving Wall for a Preventing Floods using Glass Fiber Reinforced Composite (유리섬유복합소재를 이용한 지중매설형 승하강식 홍수방지 벽체구조물)

  • Yun, Youngman
    • Journal of the Society of Disaster Information
    • /
    • 제9권4호
    • /
    • pp.462-468
    • /
    • 2013
  • Walls for preventing floods using overturning or buoyancy method have been developed as replacement construction for preventing floods in and outside country. However, as they have some problems with pre-inspection and maintenance control, Eco-moving wall structure for preventing floods was studied and first developed using Glass Fiber Reinforced Composite which has not only light weight but outstanding strength. The developed wall structure for preventing floods offering structural stability and field applicability through numerical analysis was confirmed to reduce construction expenses by around 87~95% and secure waterproof property with the inside of the wall installed rubber water stopper.

Numerical Investigation on Seepage Discharge Inside a Cylindrical Cut-off Wall (수치해석을 이용한 대형원형강재 가물막이의 침투유량 분석)

  • Ssenyondo, Vicent;Tran, Van An;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • 제34권10호
    • /
    • pp.51-60
    • /
    • 2018
  • Recently, a cylindrical cut-off wall was proposed as a new technology for temporary offshore works. The cut-off wall has a cylindrical shape, so seepage analyses are necessary to analyze the effect of wall shape. In this study, a numerical analysis was performed to investigate the seepage discharge inside cut-off walls. The numerical modeling was verified by comparing with the theoretical solution for the cofferdam with double sheet piles. Two different flow conditions were compared between 2-dimensional flow and axisymmetric flow. The results showed that the discharge of the axisymmetric flow was about 1.55 times larger than that of 2-dimensional plain flow. A parametric study was carried out by varying wall radius, penetration depth of the wall, and total head difference between in and outside of the wall. The discharge decreased with the increase of the penetration depth and the wall radius. Finally, the design equations were suggested to determine the discharge for the preliminary design of the cylindrical cut-off wall.

The Effects of Geographical Features and Configuration on the Height of Castle Wall - The Case of Hwasong in Suwon City (지형, 지세가 성곽축성 높이에 미친 영향 -수원화성을 중심으로-)

  • 박춘균;이재근
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2000
  • The main purpose of this research is to show the consideration of the geographical effects related with its features and configuration on the height of the wall in Hwasong. The method of this research is based on old documentary records and actual measuring. The result of this research is to take advantage of nature geographical features and configuration. First the castle of wall construction is based on outside defensive protection, mainly it was made of stones or bricks. And took advantage of its natural environment. According to circumstance, there were two kinds of general method to build the wall., Second It was considered, They had so many difficulty to move stones to build wall, especially to rugged hilly steep mountain. Third There were three kinds of stones to build wall, Bottom stones were piled with Big stones, because of its stability. Third There were three kinds of stones to build wall, Bottom stones were piled with Big stones, because of its stability. On top of the wall was built with small stones it shows good harmony with small, middle, big size stones. It is considered not only stability but also beauty of appearance. Fourth Placing ChiSung was able to adjust height of wall low at the same time it was also taken advantage of a active defensive power. The suggestion of this research is to take advantage f nature geographical features and at the same time it was a perfect way to save the cost of construction. The further research of this should be continued to deepen because, it is the early stage, so it is maningful of eoffering a guidance for the furder research. in this research has a number of important question remain unsolved.

  • PDF

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제17권3호
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

Automatic Insulation System in Greenhouses (온실의 자동단열시스템에 관한 연구)

  • 이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제29권4호
    • /
    • pp.117-123
    • /
    • 1987
  • This study was conducted to develop an automatic insulation system to reduce the heat loss through the wall of greenhouses during the nighttime in winter. A double covered model vinyl house was constructed, and blowers were used to fill or remove styrene pellets automatically the inside of the double-wall of the double covered vinyl house. The effects of insulation of the double covered vinyl house insulated with the styrene pellets were analyzed by comparing with the single covered vinyl house. The results obtained from this study can be summarized as follows : 1. The optimum thickness of the double-wall of the double covered vinyl house was found to be 5 to 10 cm. 2.When the outside temperature varied in the range of -8.3 to -1.5$^{\circ}C$ during the nighttime, the inside temperature of the double covered vinyl house insulated with the styrene pellets showed 7.7 to 11.7$^{\circ}C$ and the inside temperature of the single covered vinyl house showed -5.8 to 2.3$^{\circ}C$. Therefore, the effects of insulation of the double covered vinyl house insulated with the styrene pellets were confirmed to be excellent. 3. Also, the excessive increase of the inside temperature in the vinyl house was prevented by the shading effect of the double covered vinyl house insulated with the styrene pellets during the daytime. 4. When the outside temperature varied in the range of 17.7 to 30.0$^{\circ}C$ during the daytime, it was possible to keep the inside temperature at 30${\pm}$4$^{\circ}C$ in the double covered vinyl house by operating the insulation system. 5. The transmissivity of the double covered vinyl house with the styrene pellets removed was 52.4 % on the average.

  • PDF

A Study of Solar heat removal Impact with Air-Vent Wall (통기벽체적용 건물에서의 일사열 제거효과 검토)

  • Kim, Sang-Jin;Kum, Jong-Soo;Choi, Kwang-Hwan;Shin, Byong-Hwan;Chung, Yong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • 제24권2호
    • /
    • pp.25-31
    • /
    • 2004
  • Ventilation through air vent system in a building envelope is expected to be an effective measure to release solar radiation. An external surface of a wall absorbs solar radiation and transfers it to the air in the cavity. The warmed air gets buoyant force. So when openings are provided at the top and bottom of the cavity, the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. This reduces the further heat transmission into the built environment. This natural ventilation effect seems to be steady and strong. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable.