The purpose of this study is to analyze the general patterns of the floor plans and space of Usonian house which designed by Frank Lloyd Wright. this thesis can be summarized as follows : 1) F.L.Wright's houses mostly used simple geometric shapes as the basis for most of his architectural designs. In his early works, his typical floor plans were square or rectangular shapes, which gradually were transformed into various kinds of shape to make the adjustment of location of the site and shape. 2) The general patterns of floor plans of his U-houses were L-shaped or straight shaped using a $4{\times}4$ grid system. Most of U-houses consisted of 3 space: living room, workspace(Kitchen) & dining, and bedroom. Among them, a workspace worked as core role in each house. 3) Even though solid wall is the opposite concept of the transparent glass but most U-houses were designed to have solid walls on one side to provide a gallery space(to secure habitability of resident) and transparent glass walls used on the other side to connect between interior space and natural space of exterior. 4) The cantilever have not been used before Usonian house but F.L.Wright used it which take charge of functions as transfer space between inside space and outside space. 5) F.L.Wright saw the nature as a truth, so he thought the interior space would be natural and all houses must be able to adjust to the natural environment.
The Tongdo temple have been transformed continuously since its first establishment about 1300 years ago. Nevertheless three critical elements specified by 'Jajangyulsa', founder of the temple have not varied over the times but rather strengthened and strongly combined. All elements and doctrines of the religion coexist and form a harmony within the whole of the temple. This researcher examined what changes, or combinations, in spatial formation were sought for such unique structures of the Tongue temple by focusing mainly on the Sangrojun area of the temple to obtain the following findings. First. unlike a work by a Japanese researcher 'Sekino Tadashi', the east yard of the main building was found located on the section line which corresponded to the separation line of Yungkuncheokdo(營建尺度=measure running) from the edge of the Keumkangkyedan(金剛戒壇 =Buddhist platform) embankment to the corner column of the Kamrodang. This was confirmed as a result of the review of photos shown in [Chosun Kojukdobo]. Second, the number of stairs used for the Keumkangkyedan was thought to become three when the temple was firstly restored in 1379 as a result that this researcher reviewed Chinese literature 'DoSun' and [Kyedandokyung(戒壇圖經)], records by 'Lee saek' and 'Jung Shihan', studies of Yungkun measure and actual changes in the temple. Then the temple was forth restored in 1705 when the second of the stairs was changed in area and height and at the same time grounded hard for a space for a Buddhist service. Third, the roof of the main building was probably changed in shape during the Koryo period when the plane structure, furnish arrangement, emphasized front, stone lanterns of the building and political factors of that time were all considered. Fourth, the main building was Initially designed to provide a Buddhist sermon service which was assumedly followed by a similar service at a Keumkangkyedan. Thus the main building had a small window on the northern side which might be opened up to look out or otherwise go outside like a door. However, the window was probably locked up like a surrounding wall since the main building was entirely repaired after the end of Japanese invasion of Korea in 1592.
This study has main purpose to understand the traditional house, not by outside researcher's but by inside dweller's view. The house in Geochang, is descendent house of Jeong-On who was faithful scholar at Chosen Dynasty. In order to understand, I restore firstly the house form and space at traditional era, 60 years ago, and every dwellers not only family members but also servants and guests, by interviewing old matriarch. One of the main rules of the house disposition is Ancester worshipping life. Worshipping floor of Anchae, main building, is located unusually in front of Shrine for Jeong-On, in order to connect all activities directly. Sarangchae, men's building, opened to the funeral mourners, is separated by a wall because women have to serve foods and wail at the backside. Space for everyday life is separated by man/woman, insider/outsider, master/subordinate. Agricultural production is also key factor of the space allocation: big storage buildings for rice crop needed to tenant farming. Both activities of ancestor worship ceremony and guest greeting need large kitchen annex area for food preparation and serving space of rear veranda floor. A number of guests visit the house: guest-greeting activity is taken place from the family pavilion, Neungheo-Jeong and Saranchae by the social position. This study show that architectural space and form of the house reflects exactly dwellers life.
Electrical apparatuses for use in the presence of flammable gas atmospheres have to be specially designed to prevent them from igniting the explosive gas. Flameproof design implies that electrical components producing electrical sparks are contained in enclosures and withstand the maximum pressure of internal gas or vapours. In addition, any gaps in the enclosure wall have to designed in such a way that they will not transmit a gas explosion inside the enclosure to an explosive gas or vapours atmosphere outside it. In this study, we explained some of the most important physical mechanism of MESG(Maximum Experimental Safe Gap) that the jet of combustion products ejected through the flame gap to the external surroundings do not have an energy and temperature large enough to initiate an ignition of external gas or vapours. We measured the MESG and maximum explosion pressure of ternary gas mixtures(propane-acetylene-air) by the test method and procedure of IEC 60079-20-1:2010. As a result, the composition of propane gas that has lower explosive power than acetylene gas in the ternary gas mixtures makes greater effects on MESG and explosion pressure.
Due to a lack of reproducibility and visibility of the conventional equipment for westerly wave simulation, it is difficult to have indoor experiments at high school that show the stream of Hadley cell. A modified improvement of the old one improves the problem. The side wall and bottom of the new equipment is made by copper and acrylic resin, respectively, in order to clarify the difference between the water temperature inside and outside of the water tank. The equipment also has a high quality digital record for generating exact analysis of the results. And we also carried out several experiments that relate theoretical and experimental aspection of westerly wave. Temperature Detected Sheet (TDS) in flow visualization unit provides not only visual information of liquid flow, but also clear understanding of the relation between upper and lower wind flow structure. And the liquid stream simulated in indoor experiment using proposed equipment is commensurate with westerly wave in real atmosphere. The efficiency of educational properties of the proposed equipment is verified indirectly by Likert Scales survey of high school teachers.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.23
no.9
/
pp.17-23
/
2009
Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. In this paper, it describe the how to design optimal ultraviolet disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.
This study is on the general characteristics of 'Monolithic' architecture. The intentions of monolithic architecture can be assumed as an attempt to replace the formal looseness or difficulties of understanding formal complexity of modern architecture, or a trial to react against contemporary avant-garde architectural tendency typically characterized as unstableness, uncertainty, fluidity, and articulation to reestablish autonomy of architecture. Buildings in this category coincide in their extreme economy and simplicity of overall form and consistency of external appearance while showing great expressional capacity with very limited formal means. Even though monolithic architecture still seems a little unstable and ambiguous in historical aspects, it can be considered as strikingly shaped objects or autonomous forms with identities, logics, and representation that promote recognition. Using architectural techniques of scale, colors, materials and finishes, monolithic architecture shows strategically invested surfaces that mediate between the inside and the outside, and shows unexpected and mysterious autonomy. This kind of monolithic approach is also found in interior space as a separate objects that contain functional space inside, or as formal elements that overflow the boundaries of conventional architecture by eliminating the distinction between floor, wall, and ceiling.
Kim, Jong-Hun;Kim, Chung-Dong;Kim, Taik-Nam;Kim, Tae-Woo
Journal of architectural history
/
v.14
no.2
s.42
/
pp.89-101
/
2005
The bricks in Myung Dong Cathedral Church are now deteriorated by the weather such as temperature, humidity, and winds. Thus it is necessary to replace the old bricks to the restored bricks for the load bearing capacity as well as to prevent the penetrations of rains from outside. However the mortar composition is not well defined at this moment and there are literary about the mortar completions. Thus it is necessary to verify the mortar compactions between old bricks and results to bring the restoring the mortar for the replace of new bricks. The particles of mortar was collected from Myung Dong Cathedral Church and particle size was analyzed by the mortar and pestle and mechanicle floater. The X-ray diffraction and XRF of each particles are analyzed. The quartz and feldspar such as albite, kaolinite are observed in large particles(>1mm). However, the clicite was observed at lower than $43{\mu}m$ particles. In XRF analysis, the $SiO_2\;and\;K_2O$ are observed at large particles$(1mm-208{\mu}m)\;and\;CaCO_3$ is observed at small particles$(208-43{\mu}m)\;and\;CaCO_3$ is observed at small particles($208-43{\mu}m$). This is well coincide with XRD results. The optimum volume ratio of lime mortar would be 1: 2 ($CaO: SiO_2$).
The abscopal effect is a term that has been used to describe the phenomenon in which localized radiation therapy treatment of a tumor lesion triggers a spontaneous regression of metastatic lesion(s) at a non-irradiated distant site(s). Radiation therapy induced abscopal effects are believed to be mediated by activation and stimulation of the immune system. However, due to the brain's distinctive immune microenvironment, extracranial abscopal responses following cranial radiation therapy have rarely been reported. In this report, we describe the case of 42-year-old female patient with metastatic melanoma who experienced an abscopal response following her cranial radiation therapy for her brain metastasis. The patient initially presented with a stage III melanoma of the right upper skin of her back. Approximately 5 years after her diagnosis, the patient developed a large metastatic lesion in her upper right pectoral region of her chest wall and axilla. Since the patient's tumor was positive for BRAF and MEK, targeted therapy with dabrafenib and trametinib was initiated. However, the patient experienced central nervous system (CNS) symptoms of headache and disequilibrium and developed brain metastases prior to the start of targeted therapy. The patient received radiation therapy to a dose of 30 Gy delivered in 15 fractions to her brain lesions while the patient was on dabrafenib and trametinib therapy. The patient's CNS metastases improved significantly within weeks of her therapy. The patient's non-irradiated large extracranial chest mass and axilla mass also shrank substantially demonstrating the abscopal effect during her CNS radiation therapy. Following radiation therapy of her residual chest lesions, the patient was disease free clinically and her CNS lesions had regressed. However, when the radiation therapy ended and the patient continued her targeted therapy alone, recurrence outside of her previously treated fields was noted. The disease recurrence could be due to the possibility of developing BRAF resistance clones to the BRAF targeted therapy. The patient died eventually due to wide spread systemic disease recurrence despite targeted therapy.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.29
no.1
/
pp.1-9
/
2018
In this paper, we propose a film-type dual-band frequency selective structure for improving the wireless communication environment in a building. The proposed frequency-selective structure is a miniaturized structure that can control the resonant frequencies of 2.4 GHz and 5 GHz dual band through simple design parameters. We fabricated the frequency-selective surface by screen printing using conductive ink on a thin transparent film and confirmed its performance by measurement. We analyzed the attenuation performance of the unnecessary signal from the outside when the frequency-selective structure designed using the software to analyze the propagation environment performance is applied to the building. To verify the analytical results, the signal strength of the indoor environment was measured by applying the frequency-selective film fabricated on the inner wall of the actual building. The measurement results show that the dual-band frequency-selective film has 29.4 dB and 15.94 dB attenuation performance in the 2.4 GHz and 5 GHz, respectively.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.