• Title/Summary/Keyword: outside experiment

Search Result 351, Processing Time 0.028 seconds

The Correlation between Ammonia Emissions and Bedding Materials in a Cow House

  • Phan, Nhu-Thuc;Sa, Jae-Hwan;Jeon, Eui-Chan;Lee, Sang-Rak
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2010
  • Because ammonia from livestock production may substantially contribute to environmental pollution, emissions from all possible sources (housing systems, manure storage, manure application, outside grazing) should be reduced. The purpose of this study was to investigate the effect of different bedding materials on ammonia emissions in a cow house. By applying a combination of four treatment types: treatment $1-T_1$ (sawdust (50%)+sawdust pellets (50%)), treatment $2-T_2$ (sawdust (50%)+corn stalk pellets (50%)), treatment $3-T_3$ (sawdust (100%)), and treatment $4-T_4$ (sawdust (50%)+palm kernel meal pellets(50%)) as bedding materials in a cow house, the effects of such treatments on ammonia flux were assessed in approximately one month. The magnitude of ammonia emissions (mg $m^{-2}\;min^{-1}$) varied in the following order: $T_1$(2.226), $T_4$(2.052), $T_2$(1.845), and $T_3$(1.712). The patterns of pH had a decreasing trend for all bedding treatments during the experiment, and there was no significant relationship with ammonia flux. The results reveal that the most important factor influencing ammonia emissions is the physical structure of the bedding types.

Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch (가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정)

  • Kil, Gyung-Suk;Park, Dae-Won;Choi, Su-Yeon;Kim, Il-Kwon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

A Study of Spraying Curing Compound for Concrete Pavement Considering Environmental Condition in Tunnel (터널내 환경을 고려한 콘크리트 포장의 양생제 살포기준 연구)

  • Ryu, SungWoo;Kwon, OhSun;Song, GeoRuemSoo;Lee, MinKyung;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : This study is to suggest tunnel length to spray curing compound, based on the field tests. METHODS : At first field test, length from the entrance of tunnel to wet wall was checked by visual survey. The second and third test, various sensors were installed in concrete or in tunnel, such as RH sensor, temperature sensor, portable weather station and etc.. And also, test for bleeding and retaining water of concrete were conducted to evaluate environmental effect on concrete pavement. RESULTS : The result of the field experiment for tunnel length to spray curing compound indicates that length changes depending on tunnel length, season, and location. Environmental condition of a short tunnel was not much different between location near entrance and at center of tunnel. However, in case of a medium and long tunnel, effect of outside environmental condition decreased, when location moved into tunnel center of it. CONCLUSIONS : From the testing results, it can be proposed that optimum tunnel length to spray curing compound is 60m for a medium and long tunnel, and whole length for a short tunnel.

A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside (보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구)

  • Lee, Young-Lim;Park, Sang-Jun;Hwang, Il-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

The method using dynamic load and static load figures out gust factor of the membrane structure (동적하중과 정적하중을 이용한 막구조의 거스트 계수 산출 방법)

  • Wang, Ben-Gang;Jeong, Jae-Yong;You, Ki-Pyo;Kim, Young-Moon
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.19-24
    • /
    • 2008
  • The thesis is for gust factor needing when calculate the wind resistance design. For the gust factor, to the membrane structural model, carry through the wind tunnel test and the static load test. Therefore, at first through the tensile test of the fabric material, designate the material of the membrane structural model. Then, to saddle, wave, arch and point four kinds of basic shape membrane structural models, carry on the wind tunnel test, determine their dynamic load and distortion on lateral direction. Finally, according to distort situation of the membrane structure in the wind tunnel test, carry on the static load experiment outside of the wind tunnel, calculate static load which corresponding with distort. According to dynamic load and the static load, figure out gust factor of these kinds of basic membrane structure.

  • PDF

A Study on the Flow Characteristics in Computer Case by Crossflow Fan. (Crossflow fan에 의한 컴퓨터 케이스 내부의 유동특성에 관한 연구)

  • Lee, Haeng-Nam;Park, Gil-Moon;Jung, Hann-Byul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.730-736
    • /
    • 2008
  • The purpose of this study is to find out a flow characteristics when a crossflow-fan is installed inside the computer case and to provide information about the preliminary data of cooling efficiency of CPU and a flow inside and outside of a computer case. Under the condition of operating the fan inside the experimental duct we changed the position of a installation of the slot, and the experiment measured with PIV and the results are as follows. Under the influence of the crossflow-fan installed to the air discharging side, mean velocity between 35 to 45 on the point 80 of the Slot 0.2.3 of the case increased and it influences discharging the air inside of the computer case. On the left-upper end. which isn't directly influenced by the suction-discharging fan installed inside the PC, a flow occurs caused by vortex due to the Sirocco-Fan and Slot installed on the center of the right side. We can see that a flow distribution increases when the Sirocco-Fan operates and a whirl appears stronger between the slot and the suction fan. It is thought that this phenomenon is influenced by a flow while it is on the way of entering from the suction-fan and going out to the discharging-fan.

Phenomenological References : Arguments for Mentalistic Natural Language Semantics

  • Jun, Jong-Sup
    • Language and Information
    • /
    • v.8 no.2
    • /
    • pp.113-130
    • /
    • 2004
  • In a prevailing view of meaning and reference (cf. Frege 1892), words pick out entities in the physical world by virtue of meaning. Linguists and philosophers have argued whether the meaning of a word is inside or out-side language users' mind; but, in general, they have taken it for granted that words refer to entities in the physical world. Hilary Putnam (1975), based on his famous twin-earth thought experiment, argued that the meaning of a word could not be inside language users' head. In this paper, I point out that Putnam's argument makes sense only if words refer to entities in the physical world. That is, Putnam did not provide any argument against mentalistic semantics, since he erroneously assumed that meaning, but not reference, was inside our mind in mentalistic semantics. Mentalistic semanticist, however, assume that words pick out their references inside our head (instead of a possible outside world). A number of arguments for the mentalistic position come from psychology: studies on emotion and visual perception provide numerous cases where words cannot pick out entities from the physical world, but inside our head. The mentalistic theory has desirable consequences for the philosophy of language in that some classical puzzles of language (e.g. Russell's (1919) well-known puzzle of excluded middle) are explained well in the proposed theory.

  • PDF

Measurement of a Mirror Surface Topography Using 2-frame Phase-shifting Digital Interferometry

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.245-250
    • /
    • 2009
  • We propose a digital holographic interference analysis method based on a 2-frame phase-shifting technique for measuring an optical mirror surface. The technique using 2-frame phase-shifting digital interferometry is more efficient than multi-frame phase-shifting techniques because the 2-frame method has the advantage of a reduced number of interferograms, and then takes less time to acquire the wanted topography information from interferograms. In this measurement system, 2-frame phase-shifting digital interferograms are acquired by moving the reference flat mirror surface, which is attached to a piezoelectric transducer, with phase step of 0 or $\pi$/2 in the reference beam path. The measurements are recorded on a CCD detector. The optical interferometry is designed on the basis of polarization characteristics of a polarizing beam splitter. Therefore the noise from outside turbulence can be decreased. The proposed 2-frame algorithm uses the relative phase difference of the neighbor pixels. The experiment has been carried out on an optical mirror which flatness is less than $\lambda$/4. The measurement of the optical mirror surface topography using 2-frame phase-shifting interferometry shows that the peak-to-peak value is calculated to be about $0.1779{\mu}m$, the root-mean-square value is about $0.034{\mu}m$. Thus, the proposed method is expected to be used in nondestructive testing of optical components.

Visualization Experiment for Nucleate Boiling Bubble Motion on a Horizontal Tube Heater Fabricated with Flexible Circuit Board (연성회로기판 기반 수평전열관 표면의 비등기포거동 가시화 실험 연구)

  • Kim, Jae Soon;Kim, Yu-Na;Park, Goon-Cherl;Cho, Hyoung Kyu
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.52-60
    • /
    • 2016
  • The Passive Auxiliary Feedwater System(PAFS) is one of the advanced safety concepts adopted in the Advanced Power Reactor Plus(APR+). To validate the operational performance of the PAFS, detailed understanding of a boiling heat transfer on horizontal tube outside is of great importance. Especially, in the mechanistic boiling heat transfer model, it is important to visualize the phenomena but there are some limitations with conventional experimental approaches. In the present study, we devised a heater based on the Flexible Printed Circuit Board (FPCB) for a more comprehensive visualization and subsequently, a digital image processing technique for the bubble motion measurement was established. Using the measurement technique, important parameters of the nucleate boiling are analyzed.

Effect of Plant Growth Regulators on Calls Initiation and Organogenesis from Tissue Culture of Arabidopsis thaliana Stem (애기장대 줄기 조직배양에 있어서 식물생장조절제가 캘러스 형성과 기관분화에 미치는 영향)

  • Park, Jung-An;Park, Jong-Bum
    • Journal of Plant Biotechnology
    • /
    • v.30 no.3
    • /
    • pp.257-261
    • /
    • 2003
  • This experiment was carried out to investigate the effects of plant growth regulators on the organogenesis from the tissue culture of Arabidopsis thaliana stem, and the origin of the callus development. When the stem segments were cultured on medium with 2mg/L IAA or NAA, adventitious roots and trichomes were differentiated after 11 days of culture. Callus vigorously formed on medium with 2/L2,4 after 7 days of culture, but adventitious roots and trichomes were not differentiated from callus after 10 days of culture. This results suggesting that picloram is very effective auxin for the callus formation and organogenesis. Callus weakly formed on 0.05mg/L kinetin, and formed on combination of auxins(2mg/L) with 0.05mg/L kinetin. But the effect of combination of auxins and kinetin the callus formation was less than 2,4-D or picloram alone. A histological examination of callus formed on picloram showed that phloram showed that phloem parenchyma cells were divided and enlarged after 2 days of culture. Cortex parenchyma cells were divided and meristematic nodules were developed from these cells after 4 days of culture. Finally, callus formed on outside of cortex and epidermis by division of meristematic nodules after 7 days of culture.