• 제목/요약/키워드: output pattern

검색결과 744건 처리시간 0.024초

Implementation of DSP Embedded Number-Braille Conversion Algorithm based on Image Processing (DSP 임베디드 숫자-점자 변환 영상처리 알고리즘의 구현)

  • Chae, Jin-Young;Darshana, Panamulle Arachchige Udara;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • 제11권2호
    • /
    • pp.14-17
    • /
    • 2016
  • This paper describes the implementation of automatic number-braille converter based on image processing for the blind people. The algorithm is consists of four main steps. First step is binary image conversion of the input image obtained by the camera. the second step is segmentation operation by means of dilation and labelling of the character. Next step is calculation of cross-correlation between segmented text image and pre-defined text-pattern image. The final step is generation of brail output which is relevant to input image. The computer simulation result was showing 91.8% correct conversion rate for arabian numbers which is printed in A4-sheet and practical possibility was also confirmed by using implemented automatic number-braille converter based on DSP image processing board.

Complications amd Mortality After Coronary Artery Bypass Graft Surgery; Collective Review of 61 Cases (관상동맥우회수술후 합병증과 사망율에 대한 임상적 고찰;61례 보고)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.526-531
    • /
    • 1993
  • Sixty-one consecutive patients with coronary artery bypass graft for myocardial revascularization were retrospectively reviewed to analyze various pattern of postoperative complication and death during hospital stay from Nov. 1988 to Oct. 1992. Fortytwo of the patients were male and nineteen female. The mean age was 56 and 51 years in male and female. Preoperative diagnosises were unstable angina in 14 of patients, stable angina in 28, postmyocardial infarction state in 15, and state of failed percutaneous transluminal coronary angioplasty in 4. 141 stenosed coronary arteries were bypassed with use of 20 pedicled internal mammary artery and 124 reversed saphenous vein grafts. Postoperative complications and perioperative death were as follows: 1. Of 61 patients undergoing operation, peri and postoperative over all complication occured in 15 patients [ 25% ]; newly developed myocardial infarction in 4, intractable cardiac arrhythmia including atrial fibrillation and frequent ventricular premature contraction in 3, bleeding from gastrointestinal tract in 2, persistent vegetative state as a sequele of brain hypoxia in 1, wound necrosis in 1, left hemidiaphragmatic palsy in 3 and poor blood flow through graft in 2. 2. Operative mortality was 8%[5 patients]. 3 out of these died in operating room; 1 patient by bleeding from rupture of calcified aortic wall, 1 by air embolism through left atrial vent catheter, 1 by low cardiac output syndrome. 2 patients died during hospital stay; 1 by acute respiratory distress syndrome with multiuple organ failure, 1 by brain death after delayed diagnosis of pericardial tamponade.

  • PDF

A Destruction Pattern Analysis of a Turbo-Molecular Pump According to the Foreline Clamp Damage in an ICP Dry Etcher for 300 mm Wafers

  • Jeong, Jinyong;Lee, Intaek;Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제24권2호
    • /
    • pp.27-32
    • /
    • 2015
  • We analyzed the destruction patterns of a turbo-molecular pump (TMP) resulting from its sudden exposure of a foreline to the atmospheric pressure due to a destruction of the foreline connecting clamp of an ICP dry etcher for 300 mm wafers during high-vacuum operation ($5{\times}10^{-6}$ Torr). Unlike in the case of view port's breakage, the TMP's rotor module was crashed inside the chamber. The primary damage resulted from the collision of the blades and stators, and the secondary damage resulted from the breaking of the rotor - driving shaft assembly. The fixing screws of the rotor and axial shaft were bent and broken when the TMP controller output the maximum current even after the crash event. Electrical power consumption analysis of the TMP power controller confirmed it. The stress distributions were analyzed by a finite element method using CFD-ACE+ multi physics software. Rotating inertia of each parts and kinetic energies were calculated as well. 68% of the rotational kinetic energy is deposited by the rotor - shaft module.

Direct writing of multi-layer diffraction grating inside fused silica glass by using a femtosecond laser (펨토초 레이저를 이용한 실리카 내부의 다층 회절격자 가공 기술)

  • Choi, Hun-Kook;Kim, Jin-Tae;Sohn, Ik-Bu;Noh, Young-Chul
    • Laser Solutions
    • /
    • 제14권3호
    • /
    • pp.17-20
    • /
    • 2011
  • We fabricated a multi-layer diffraction grating inside fused silica glass by using a femtosecond laser direct writing method. The femtosecond laser with a wavelength of 515 nm, a pulse width of 250 fs, a repetition rate of 100 kHz, and an average output power of 6 W was used. Two layer diffraction grating with a grating period of $6{\mu}m$ was successfully fabricated with the layer gap of 0.5, 1, 2, 3, and $5{\mu}m$, respectively. Also, we investigated the diffraction pattern by illuminating a He-Ne laser beam. Finally, we demonstrated the diffraction grating with a grating period of $3{\mu}m$ by adjusting the gap of each layer with a grating period of $6{\mu}m$. Femtosecond laser direct writing technology of multi-layer has a potential to fabricate the diffraction grating with a grating period of below $1.5{\mu}m$.

  • PDF

A Ten-year Bibliometric Analysis of Research Trends in Three Leading Ecology Journals during 2003-2012

  • Saravanan, G.;Dominic, J.
    • Journal of Information Science Theory and Practice
    • /
    • 제2권3호
    • /
    • pp.40-54
    • /
    • 2014
  • This paper attempts to highlight quantitatively the growth and development of literature in the field of ecology in terms of publication output using the resource Web of Science$^{(R)}$. The focus of this analysis was to study the literature on ecology published in three journals, viz., Ecology Letters, Trends in Ecology & Evolution, and Annual Review of Ecology Evolution and Systematics. 2946 records were retrieved for 10 years (2003-2012). The study revealed that multiple authorship in the field with collaborations of two (30.31%) and three authors (19.89%) was dominant. The Degree of collaboration, Collaborative coefficient, and Collaborative index were calculated and the applicability of Lotka's law was tested. The study identified five-year patterns in research trends, using the three studied journals, to see if the subjects of focus changed within a decade. The most productive institution was University Calif. Davis, USA, followed by University Calif. Santa Barbara, USA, and University Queensland, Australia, and the most productive countries were the USA followed by UK and Canada.

Symmetric Microwave Lens with Uniform Insertion Loss for Broad-band and Wide Beam Steering Coverage (균일한 삽입손실을 갖는 광대역 빔 조향용 대칭형 초고주파 렌즈)

  • 김인선;이광일;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제13권3호
    • /
    • pp.279-287
    • /
    • 2002
  • In this paper, a symmetric microwave lens to steer wide angle and to operate at broad band frequency range for a linear phased array transmitter was designed. To get accurate beam steering performance far a linear phased array transmitter, uniform amplitude transmission characteristics of microwave lens was focused. The measured result for the insertion loss deviation between Input and output ports of microstrip lens with 8 beam ports and 8 array ports was $\pm$3.1 ㏈ over 6~18 ㎓ band, which was very uniform characteristics. Using 8 elements linear array antenna, it was confirmed the radiation beam could be steered over $\pm$60$^{\circ}$ in azimuth. And the measured lens performance data and multi-beam steering pattern were presented.

Improve the Efficiency of Hybrid Solar LED Street Lamp Controller (하이브리드 태양광 LED 가로등 컨트롤러의 효율 개선)

  • Yun, Jung-Hyun;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제28권2호
    • /
    • pp.131-136
    • /
    • 2015
  • We develop the 60 W class hybrid solar LED street lamp controller. The controller is providing power via an inverter in the day with the least solar cell and battery and charging the battery for the ESS, acts as a power failure, the built-in battery. Rated output of the fabricated LED street lamp is 300 W or greater battery capacity 300 Wh, discharge time 10 hr, LED street lamp efficiency showed a very high level of light efficiency by about 127 lm/W. In addition, as a result of light distribution pattern according to the distance and the light intensity measurement will be able to ensure a very high quality, show the constant brightness in the distance from the road lights 6 m is about 35~40 lux in uniformity ratio. The proposed hybrid solar LED street lamp system showed a high energy capacity of approximately 1.5 to 152.7% power generation efficiency than typical conventional solar street lamp.

Anisotropic Whispering Gallery Modes Formed in Various Transformation Cavities (다양한 변환 공진기에 형성되는 비등방성 속삭임의 회랑 모드)

  • Kim, Inbo;Choi, Muhan
    • Korean Journal of Optics and Photonics
    • /
    • 제29권3호
    • /
    • pp.104-109
    • /
    • 2018
  • We explain the basic principle of transformation optics, and introduce several design techniques for transformation cavities that can maintain the characteristics of whispering gallery modes (WGMs) even if the cavity is strongly deformed from a circular shape. As a method of obtaining various transformation cavities under a specific conformal mapping, we suggest a method of parallel movement of the initial cavity domain, and a method of rotating the ellipse as a cavity domain. The internal wave pattern and the far-field output characteristics of several designed resonant modes are numerically calculated. From these results, it is confirmed that a variety of GRIN resonators are possible for a given conformal coordinate transformation.

KOMPSAT-2 Payload Downlink System Verification (아리랑 위성 2호 탑재체 하향링크 시스템 검증)

  • Lee, Jin-Ho;Kim, Hui-Seop;Cheon, Yong-Sik
    • Aerospace Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.108-113
    • /
    • 2006
  • This paper includes the test results of KOMPSAT-2 payload downlink system which were measured for the purpose of performance verification. The antenna beam patterns which indicates the status of the interface & antenna itself, were measured as well as the antenna VSWR. The checkout of the transponder & its spectrum was followed and this made sure that there was no spurious output distinguished. Finally a test for BER verification was conducted between satellite and receiving system for their compatibility through the antenna-to-antenna connection using an antenna hat. Verification tests for an RF system should be performed after relocation, integration and test for environments in order to make sure that no degradation happens.

  • PDF

Operation Performance of a Polymer Electrolyte Fuel Cell Cogeneration System for Residential Application (가정용 고분자연료전지 시스템의 운전 방법에 따른 성능 비교)

  • Lee, W.Y.;Jeong, K.S.;Yu, S.P.;Um, S.K.;Kim, C.S.
    • Journal of Hydrogen and New Energy
    • /
    • 제16권4호
    • /
    • pp.364-371
    • /
    • 2005
  • Fuel cell systems(FCS) have a financial and environmental advantage by providing electricity at a high efficiency and useful heat. For use in a residence, a polymer electrolyte fuel cell system(PEFCS) with a battery pack and a hot water storage tank has been modelled and simulated. The system is operated without connection to grid line. Its electric conversion efficiency and heat recovery performance are highly dependent on operation strategies and also on the seasonal thermal and electric load pattern. The output of the fuel cell is controlled stepwise as a function of the state of the battery and/or the storage water tank. In this study various operation strategies for cogeneration fuel cell systems are investigated. Average fuel saving rates at different seasons are calculated to find proper load management strategy. The scheme can be used to determine the optimal operating strategies of PEFCS for residential and building applications.