The Analysis of Environmental Effects on Maximum Output Power Change of Crystalline Silicon Photovoltaic Module (결정질 실리콘 태양전지모듈의 최대 출력특성 변화에 영향을 미치는 환경요인)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Ji-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.12-13
    • /
    • 2007
  • In this paper, we studied the analysis of environmental effects on maximum output power change of crystalline silicon photovoltaic module. During the test period, there was a 5% reduction of maximum output power on an average. And the degree of output power uniformity became better compared to initial value. Using climate data like rain, snow and dust, we tried to find the reasons for maximum power fluctuation. The surface of PV module was monitored using microscope and infrared camera to study temperature distribution. The further analysis is described in the following paper.

  • PDF

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.

Efficiency Improvement of Uninterruptible Power Supply Systems (무정전 전원장치 효율 향상에 대한 연구)

  • Oh, Heun-Gil;Kwon, Jong-Won;Park, Yong-Man;Odgerel, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

A Study on the Mock-up test for applying BIPV in the external curtain Wall (수직 외벽면 적용 BIPV의 Mock-up 실험연구)

  • Lee, Han-Myoung;Oh, Min-Suk;Kim, Hway-Suh
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.110-118
    • /
    • 2009
  • This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard($950\;{\times}\;980mm$) large($950\;{\times}\;1960mm$)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1 W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.

Online output power measurement of full-bridged MOS-FET RF power inverter operating at shortwave frequency

  • Suzuki, Taiju;Suyama, Tetsuji;Yamamoto, Tetsuya;Ikeda, Hiroaki;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1920-1923
    • /
    • 1991
  • An online RF power measurement is needed for the full-bridged MOS-FET RF power inverter because the output current and/or voltage waveform is other than sinusoidal. In order to satisfy the requirement, the online measurement of the output power of this type of RF power inverter by the use of the PC-98 personal computer has been presented. The current and voltage waveforms are sensed by the digital oscilloscope probes so as to obtain the instantaeous power and they are entered into the PC98 personal computer so as to average the instantaneous powers. The RF power of up to 1 kw at 1 MHz measured for the power inverter at the output transformer. This method was confirmed to be applied to evaluate the load resistance change with temperature.

  • PDF

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

Input-Series Multiple-Output Auxiliary Power Supply Scheme Based on Transformer-Integration for High-Input-Voltage Applications

  • Meng, Tao;Ben, Hongqi;Wei, Guo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.439-447
    • /
    • 2012
  • In this paper, an input-series auxiliary power supply scheme is proposed, which is suitable for high input voltage and multiple-output applications. The power supply scheme is based on a two-transistor forward topology, all of the series modules have a common duty ratio, all the switches are turned on and off simultaneously, and the whole circuit has a single power transformer. It does not require an additional controller but still achieves efficient input voltage sharing (IVS) for each series module through its inherent transformer-integration strategy. The IVS process of this power supply scheme is analyzed in detail and the design considerations for the related parameters are given. Finally, a 100W multiple-output auxiliary power supply prototype is built, and the experimental results verify the feasibility of the proposed scheme and the validity of the theoretical analysis.

Grid-friendly Characteristics Analysis and Implementation of a Single-phase Voltage-controlled Inverter

  • Zhang, Shuaitao;Zhao, Jinbin;Chen, Yang;He, Chaojie
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1278-1287
    • /
    • 2017
  • Inverters are widely used in distributed power generation and other applications. However, their lack of inertia and variable impedance may cause system instability and power transfer inaccuracy. This paper proposes a control scheme for a single phase voltage-controlled inverter with some grid-friendly characteristics. The proposed control algorithm enables the inverter to function as a voltage source with an inner output impedance in both the islanded and grid-connected modes. Virtual inertia and rotor equations are embedded in the PLL part. Thus, the frequency stability can remain. The inner output impedance can be adjusted freely, which helps to accurately decouple and transmit the output active and reactive power. The proposed inverter operates like a traditional synchronous generator. Simulations and experiments are designed and carried out to verify the proposed control strategy.

Operation Scheme for a Wind Farm to Mitigate Output Power Variation

  • Lee, Sung-Eun;Won, Dong-Jun;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.869-875
    • /
    • 2012
  • Because of the nature of wind, the output power of wind turbines fluctuates according to wind speed variation. Therefore, many countries have set up wind-turbine interconnection standards usually named as Grid-Code to regulate the output power of wind farms to improve power system reliability and power quality. This paper proposes three operation modes of wind farms such as maximum power point tracking (MPPT) mode, single wind turbine control mode and wind farm control mode to control the output power of wind turbines as well as overall wind farms. This paper also proposes an operation scheme of wind farm to alleviate power fluctuation of wind farm by choosing the appropriate control mode and coordinating multiple wind turbines in consideration of grid conditions. The performance of the proposed scheme is verified via simulation studies in PSCAD/EMTDC with doubly-fed induction generator (DFIG) based wind turbine models.