• 제목/요약/키워드: outlet structure

검색결과 168건 처리시간 0.046초

저압용 방수 콘센트의 개발 및 평가에 관한 연구 (A Study on the Development and Estimation of Waterproof Outlet for Low Voltage)

  • 최충석;김창성
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.181-185
    • /
    • 2008
  • In this paper, we investigates accident actual conditions of electric outlet for low voltage that is used into interior and clear hazardous factor. Electric outlet for general can know that melting of socket-outlet and carbonization of support occur if a contaminant becomes burnout because is flowed in. Existent outlet consists of structure that special quality is good but inflow of a contaminant is easy when is dry. But, waterproof outlet passes silicon layer and have connected structure plug. As developed outlet covers whole surface and back side, interval was shut. Safety pin of developed outlet was established to operate to vertical direction. Therefore, we estimate that contribute on prevention of electrical disaster if use developed outlet to a restaurant, a laundry, a laboratory etc.

발전소 수중방류구조 내 수평유공판 설치에 따른 거품발생 저감효과에 관한 실험적 연구 (Experimental Investigation on the Efficiency of Reducing Air Bubble Formation by Installing Horizontal Porous Plate in the Submerged Outlet Structure of Power Plant)

  • 오상호;오영민;강금석;김지영
    • 한국해안·해양공학회논문집
    • /
    • 제20권5호
    • /
    • pp.472-481
    • /
    • 2008
  • 이 연구에서는 보령화력발전소 방수로 수중방류구조에 대한 수리모형실험을 수행하여 수중방류구조 내 흐름 특성을 고찰하고, 수평 유공판 설치에 따른 거품저감 효과를 검토하였다. 수중방류구조 내 단면평균유속은 설계시 거품의 외해 유출 방지를 위해 고려한 목표값 1 m/s 이내에 분포하였다. 또한, 수중방류구조 내 2차 낙하 위치에 수평 유공판을 설치함에 따라 거품의 수중 최대관입깊이가 30~50% 감소함을 확인하였다. 특히, 2차 낙하 위치에 구멍의 크기가 20 cm 정도인 사각구멍형 유공판을 설치하고, 중앙부는 무공 구조로 제작하여 낙하 에너지를 소산시키게 될 경우, 가장 효과적으로 수중에 관입되는 거품 발생량을 저감시킬 수 있을 것으로 기대된다.

PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구 (Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV)

  • 홍지우;신수용;안병권
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

토출구의 형상에 따른 원심 송풍기의 성능특성 (Characteristics of Performance for Centrifugal Blower with Different Outlet Geometries)

  • 김재원;김진민;이국도
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.70-77
    • /
    • 2004
  • Comprehensive investigation on the outlet's geometric shapes of a centrifugal blower with higher inlet resistance than an atmospheric pressure is carried out for improvements of its performance. Most unwanted behaviors of such blower are pulsating flows because of unbalance between inflows and outflows in a scroll casing. In order to reduce this undesirable phenomenon a triump is made for both the shape of outlet duct and an accessory structure inserted in the outlet port of the blower. The modification on the shape is concerned with the contraction of cross sectional area and the attached structure is for an intentional obstruction to cause a flow resistance. The details of the modification are examined for different cases and results. The methodologies for the work are performance evaluations including noise level and velocity measurements with PIV Consequently, the performance of improved system is close to that of the system operating with atmospheric pressure at the inlet.

  • PDF

가시화기법을 이용한 룸 에어컨 내부의 유동 구조에 관한 연구 (Study on Flow Structure inside Room Air Conditioner Using Visualization Technique)

  • 이수홍;라선욱;강근;고한서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2713-2717
    • /
    • 2008
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure with various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan. From the visualization of the inner flows, the origins of the noise inside the RAC and the condensation points around the outlet parts of the cold air have been observed and the solution of the problems can be proposed in this study.

  • PDF

패션아울렛 소비자의 캐주얼 및 정장 의류제품 추구혜택과 만족도 연구 (A Study on Pursuing Benefit and Satisfaction at Casual and Official Wear of Fashion Outlet Users)

  • 박혜원;박주형
    • 한국의류학회지
    • /
    • 제29권3_4호
    • /
    • pp.523-534
    • /
    • 2005
  • This study was to examine the factor structure of pursuing benefit and satisfaction at casual and official wear, to analyze the differences of pursuing benefit, satisfaction, and clothing purchase behavior among the consumer groups segmented by store pursuing benefits, and to provide useful information for establishment of marketing strategies. The subjects were 500 female consumers experienced in purchasing clothes at fashion outlet stores. A total of 500 questionnaires were analyzed with $X^2$-test, ANOVA, factor analysis and Duncan's multiple range test. The results were as follows: 1. Pursuing benefit and satisfaction at casual wear and official wear were composed of 5 factors. 2. Pursuing benefit and satisfaction at casual and offcial wear, and clothing purchasing behavior variables such as informants, frequency of purchase, shopping time, and average monthly expenditure on clothes were significantly different among the 3 segmented groups. Product pursuing group was shown to seek higher level of esthetic feeling, suitability for self image and body, fsshion and symbolic meaning of brand than other groups in casual and official wear and to be most satisfied at symbolic meaning of brand, social recognition, and practicality in casual wear of outlet and at suitability and social recognition in official wear of outlet. Store convenience pursuing group was shown to seek higher level of suitability for self image and body, quality, and practicality than other groups in casual and official wear and to be most satisfied at quality and practicality in casual wear of outlet and at practicality and suitability in of cial wear of outlet. Price pursuing group was shown to seek and to be most satisfied at practicality in casual and official wear of outlet.

장방형 2차 침전지 유출부의 구조가 유동 및 성능에 미치는 영향에 대한 수치 해석적 연구 (Numerical Analysis of the Outlet Structure Effect on the Flow and Settling Performance of the Rectangular Clarifiers)

  • 김영철;박무종;신동진
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.557-565
    • /
    • 2006
  • Proper operation of clarifier partly depends on outlet conditions. Effluent has to be uniformly withdrawn to prevent scouring of settled sludge and carry over of settling sludge from the clarifier. In this paper, 3-D numerical model was employed to analyze the flow and settling performance of the rectangular clarifier. There were two simulation conditions of which in the same clarifier, the first one was assumed to have a 11.5 meter weir length and the second has 8.5 meters. Shape, location and placement of the weir structure were different, but both of those outlets meet weir loading design criteria. Simulation results indicate that clarifier with longer weir generally gave strong and unstable currents at the mid-stream where the weir starts while in the clarifier with short and relatively simple weir, uniform and stable flow was observed in most parts of the settling zone, and especially at the weir region. These flow conditions affected settling performance. Effulent SS concentration from clarifier equipped with the long and complicated placement of weir was 24.5 mg/L, but 7.0 mg/L from the clarfieir having short weir length. From this study, it can be concluded that as reported from other studies, weir loading does not guarantee settling performance and 3-D numerical model can be a useful tool for determining and validating outlet structure.

유체 진동기에 의해 생성된 제트의 유동가시화 (Flow Visualization of a jet generated by a sweeping jet actuator)

  • 박통일;김대겸
    • 한국가시화정보학회지
    • /
    • 제14권3호
    • /
    • pp.22-27
    • /
    • 2016
  • A sweeping jet actuator (SJA) is an instrument generating pulsing jets with no moving elements. Because of its simple design and high durability to shock and vibration, SJA has recently drawn increasing attention for the application to flow control such as aerodynamic control of a wing and thrust vectoring of a jet engine. However, experimental and numerical studies on SJA have been limited to internal flow structure of SJA. In this study, we investigated the flow structure and its variation in the outlet of SJA. We carried out the experiment to understand the flow structures using PIV (Particle Image Velocimetry). The flow structure varies with a degree of the outlet and volume flow rate. There is leaking process during half jetting cycle. The process of the main jet can occur because the jet moving time increased from one side to the other side.

Standby Mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 관한 연구 (A Study on the Flame Pattern and the Electrical Properties of Electric Outlet Fired at Standby Mode)

  • 최충석;송길목;김형래;김향곤;김동욱;김동우
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.39-44
    • /
    • 2002
  • Standby mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 대해서 분석하였다 탄화 패턴을 분석한 결과 불꽃은 약 50~70cm 정도 방사되었다. 가연물에 착화된 후 약 150sec 경과하였을 때 온도가 약 $300^{\circ}c$까지 상승했으며, 화염은 ceiling jet을 형성하며 급속도로 확산되었다. 트래킹은 극간의 최단거리를 형성하며 이루어졌으며 저항 값은 약 100~300$\Omega$을 나타냈다. 칼받이를 금속 현미경으로 분석한 결과 정상 부분은 비정질 구조를 나타냈으나, 트래킹에 의해 소손된 부분은 수지상 조직(dendrite structure)과 보이드(void)가 고르게 분포되어 있음을 알 수 있다. 용융된 칼받이를 SEM 및 EDX로 분석한 결고 ㅏ정상 부분과 용융된 부분의 구조와 조성 변화에 차이가 있다.

공기연행 수치모형을 이용한 발전소 거품저감 수중방류구조 설계 (Design of the Submerged Outlet Structure for Reducing Foam at a Power Plant using a Numerical Model Simulating Air Entrainment)

  • 김지영;강금석;오영민;오상호
    • 한국해안·해양공학회논문집
    • /
    • 제20권5호
    • /
    • pp.452-460
    • /
    • 2008
  • 발전소의 냉각수 방류과정에서 대량으로 발생하는 거품의 제거를 위하여 지금까지 소포제와 확산방지 막에 의존해왔지만 유지보수나 비용 등의 문제로 안정적인 구조물에 의한 거품발생 방지 방안 마련이 요구되어왔다. 따라서 본 연구에서는 거품저감 구조물 설계 기술을 확보하기 위하여 공기연행 해석이 가능한 난류 수치 모형을 적용해 보았다. 방류수의 낙하양상에 따라 공기연행률의 차이가 있고 차단벽의 잠김 깊이와 통과 유속에 따라 연행공기의 유출률이 달라지므로 각 Case에 대한 비교를 통해 적정 단면을 설계할 필요가 있다. 본 연구에서는 단면 형상에 따른 공기 연행률과 유출률을 비교하여 거품의 발생 및 유출이 최소가 되는 단면을 찾았으며, 설계 기준은 현장 여건 특히, 바닥 수심고와 월류양상 등에 따라 달라질 수 있으나 수중 방류구 통과 유속은 1 m/s이내가 되도록 하고 차단벽의 잠김 깊이는 최소한 수중 방류구 단면의 수직고 이상은 되어야 함을 알 수 있었다.