• 제목/요약/키워드: outer lead

검색결과 142건 처리시간 0.031초

헌종왕후 칠순 신찬 10곡도병과 신축신찬의궤에 나타난 복식연구 (A Study of Costumes lllustrated in the Ten folding screens on Queen Myong-hun's 70th Birthday Celebration(헌종왕후 칠순 진찬도병) and Described in the Prospectus of the Celebration Ceremony(신축진 찬의궤))

  • 유송옥
    • 복식
    • /
    • 제32권
    • /
    • pp.31-43
    • /
    • 1997
  • The costumes on a royal ceremony and the changes thereafter during the Korea Empire(1897-1910) have been elucidated through the review on the paintings on Queen Myong-Hun's 70th birthday celebration and the prospectus of the ceremony. Queen Myong-Hyn wore ceremonial gown in deep blue with 51 embroidered phoenix on it. The deep blue color the royal color in the Korea Empire replaced former red color. Go-jong wore violet crown and ceremonial suit in gold color. Twenty one kinds of court dance were offered during the celebration ceremony. Costumes therein appear to have an order according to the role ofdancers. most female dancers(in 17 performances not else-where specified) wore a rather common cos-tume-flower cap outer silk garent in green hand veils in 5 colors silk skirt in red) embroidered silk belt in red and shoes in green. In Sun-you-ak two female lead dancers were red hat decorated with tiger whisker deep blue outer garment wide red belt silk boots in black bow and arrows on back and a sword and a whip in hands. In Choonaang-jon a fe-male solo dancer wore a silk outer garment in yellow silk skirt in red green lorum embroidered silk belt in red wrist band of gold embroidered red silk and 5 color hand veils. In Yon-wha-dae two young girl dancers wore lotus-form crown green outer garment wide pants in red silk red silk skirt red silk belt hand veils in jade color and silk shoes in deep red. In Moo-go 4 female dancers each wore long waist coat in blue red white and warm light green in addition to the above-mentioned common costume. In Gumkee-moo 4 female dancers wore hatlike wool helmet outer garment with narrow sleeve long silk waist coat in blue combat belt in deep blue silk and dance swords in both hands. In Youk-wha-dae 6 female dancers each wore a long waist cost in red deep blue violet pale pink green and jade color. Green color of outer garment in the above-mentioned common costume of female dancers appears intersting. Although the color was shown as yellow in the screen paintings actually it was green as evidenced by the prospectus of the celeebration ceremony.

  • PDF

Development of a Novel Noncontact ECG Electrode by MEMS Fabrication Process

  • Mathias, Dakurah Naangmenkpeong;Park, Jaesoon;Kim, Eungbo;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.150-154
    • /
    • 2016
  • Contact electrodes pose threats like inflammation, metal poisoning, and allergic reaction to the user during long term ECG procedure. Therefore, we present a novel noncontact electrocardiographic electrode designed through microelectromechanical systems (MEMS) process. The proposed ECG electrode consists of small inner and large outer circular copper plates separated by thin insulator. The inner plate enables capacitive transduction of bio-potential variations on a subject’s chest into a voltage that can be processed by a signal processing board, whereas the outer plate shields the inner plate from environmental electromagnetic noise. The electrode lead wires are also coaxially designed to prevent cables from coupling to ground or electronic devices. A prototype ECG electrode has an area of about 2.324 cm2, is very flexible and does not require power to operate. The prototype ECG electrode could measure ECG at about 500 um distance from the subject’s chest.

Influence of Modeling Errors in the Boundary Element Analysis of EEG Forward Problems upon the Solution Accuracy

  • Kim, Do-Won;Jung, Young-Jin;Im, Chang-Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.10-17
    • /
    • 2009
  • Accurate electroencephalography (EEG) forward calculation is of importance for the accurate estimation of neuronal electrical sources. Conventional studies concerning the EEG forward problems have investigated various factors influencing the forward solution accuracy, e.g. tissue conductivity values in head compartments, anisotropic conductivity distribution of a head model, tessellation patterns of boundary element models, the number of elements used for boundary/finite element method (BEM/FEM), and so on. In the present paper, we investigated the influence of modeling errors in the boundary element volume conductor models upon the accuracy of the EEG forward solutions. From our simulation results, we could confirm that accurate construction of boundary element models is one of the key factors in obtaining accurate EEG forward solutions from BEM. Among three boundaries (scalp, outer skull, and inner skull boundary), the solution errors originated from the modeling error in the scalp boundary were most significant. We found that the nonuniform error distribution on the scalp surface is closely related to the electrode configuration and the error distributions on the outer and inner skull boundaries have statistically meaningful similarity to the curvature distributions of the boundary surfaces. Our simulation results also demonstrated that the accumulation of small modeling errors could lead to considerable errors in the EEG source localization. It is expected that our finding can be a useful reference in generating boundary element head models.

개의 소장에서 관찰된 뼈와 같은 형태의 나무 이물 (A Bone-like Small Intestinal Wooden Foreign Body in a Dog)

  • 정석영;김두;안소저;박인철;우흥명;박선일
    • 한국임상수의학회지
    • /
    • 제23권3호
    • /
    • pp.375-379
    • /
    • 2006
  • Detection of wooden foreign body represents a clinical challenge. Wood is typically radiolucent, so wooden foreign bodies are generally cannot be seen on survey radiography. Failure to locate and remove foreign bodies can lead the patient to the long-term secondary inflammatory reactions or infections. The dog described in the present report ingested a wooden foreign body(cotton swab stick) a year ago. The foreign body remained in the intestinal tracts which were attached to each other due to the prior abdominal operation. The wooden piece in the intestine functioned as a nidus and inorganic matters were gathered forming calculus on the outer layer of foreign body. In the radiograph, the foreign body appeared to be a chicken bone which of it's inner area was more radiolucent than the outer layer. Because the wooden foreign bodies that have remained for long time in the intestinal tract can be seen like a bone by mineralization, the diagnosis of the wooden foreign bodies should be done prudently.

소매의 동작기능성에 관한 인간공학적 연구 (An Ergonomic Study on Functional Utility of Movement in Sleeves)

  • 최해주
    • 한국의류학회지
    • /
    • 제19권5호
    • /
    • pp.826-841
    • /
    • 1995
  • This study is concerned with the functional utility of movement in sleeve from an ergonomic viewpoint. Experiments were carried out which include 43 upper extremity segments, 21 motions and 35 female subjects. The major conclusions of the study are. 1. The expansion rate of upper extremity was higher in length than in circumference mesurements. The amounts of expansion were, especially high (more than 60mm) for inner arm length, axillary arm circumference, and outer arm length. Therefore, a lot of ease is necessary for these parts. On the other hand, armhole circumference, forearm circumference, and wrist circumference had low rates of expansion. The sleeve cap length was also contracted in all motions. 2. The expansion rate and the range of expansion and contraction were higher in the upper arm than in the forearm. The main points of expansion were the axillary and elbow parts. The segment of maximum expansi (rate of 44.8%) was Iii of axillary parts. As the body surface expands mainly in some segments, it is desirable to allow ease to the main segments of expansion. 3. In a basic sleeve, necessary ease was lacking in the measurements for outer arm length and axillary arm circumference, while it was too large in armhole circumference, forearm circumference, wrist circumference, and sleeve cap length. Therefore, a basic sleeve is inadequate as a functional sleeve for hard work in point of functional utility of movement. Wider application of these findings would lead to an improvement in the comfort of workers.

  • PDF

Research of Novel Water Cooling Jacket for Explosion-proof Motor

  • Wang, Yu;He, Huiming;Bai, Baodong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.67-71
    • /
    • 2014
  • The well tightness of the coal mining water-cooling explosion-proof motor results in difficult heat dissipation, high hydraulic pressure is needed to increase the cooling effect. However, high hydraulic pressure may lead motor shell to deform, which makes it difficult to change the motor and maintain the motor unit. The method of adding keyhole caulk weld spots on the outer cooling water jacket was proposed to solve the problem. Based on the elasticity mechanics equations and the principle of finite element method the stresses and the deformations of the traditional and novel outer cooling water jacket were calculated separately. A hydraulic pressure experiment of the both cooling water jackets was constructed. Obviously, the stress and the deformation of the novel cooling water jacket are lower. The experimental result is consistent with the simulation results. It is effective to reduce the stress and the deformation of the cooling water jacket by adding the keyhole caulk weld spots.

흥미있는 이물례 (Interesting Foreign Bodies)

  • 박옥희;김기주;김호성;조중환
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1981년도 제15차 학술대회연제순서 및 초록
    • /
    • pp.5.1-5
    • /
    • 1981
  • 흥미있는 이물 5례를 치험하였기에 보고하는 바이다. 증례 1 : 7세남아에세 Tracheostomy outer cannula관이 삭아 부러져서 Rt. main bronchus례 들어있었던 예. 증례 2 : 51세 남자 trachea에 걸쳐 있었던 한의 침구용 침. 증례 3 : 10개월 여아의 식도제이협착부에, 입밖까지 실 달린채로 걸려 있었던 낚시 바늘. 증례 4 : 16세 남자의 식도제삼협착부에 끝(첨단)이 위로 향해 열려있었던 안전 pin. 증례 5 : 20세남자에서 큰 엽총총알이 Rt. mastoid process 밑을 통하여 Rt. mastoid process와 foramen magnum(skull babe) 중간점에 있는 것을 관혈적으로 제거하였다.

  • PDF

Dental Plaque Streptococci가 생산하는 세포외 다당류에 관한 연구 (STUDIES ON THE EXTRACELLULAR POLYSACCHARIDES PRODUCED BY ISOLATED DENTAL PLAQUE STREPTOCOCCI)

  • 정태영
    • 대한치과의사협회지
    • /
    • 제9권12호
    • /
    • pp.819-822
    • /
    • 1971
  • For this investigation, author isolated Streptococcus mitis strain SD-9 from the bacterial flora in the human dental plaque, which was incubated in brain-heart infusion media containing 5% sucrose at 37℃ for 24 hours. For the cytochemical demonstration of polysaccharide produced by this strain, a modified thiosemicarbazide osmium method (Critchley et al., 1967) was used. After fixation with this reagent, the harvested cells was suspended in 1% agar for the higher concentration of cells(Kellenberger et al., 1964). And they were dehydrated in the various concentration of ethanol, and embedded in Epon 812(Luft, 1961). Sectioning was done with the Sorvall MT-2 Porter Blum ultramicrotome by means of a glass knife, and the sections were stained with saturated uranyl acetate and lead citrate (Raynolds, 1963). All preparations were examined in a electron microscope, Hitachi HU-ll E-1 type. The morphological features of extracellular polysaccharide produced by Streptococcus mitis strain SD-9 were appeared in 3 structurally different forms, those are, electron dense fibrillar material linearly arranged adjacent to the outer surface of cell wall, highly electron dense globular material adjacent to the outer surface of cell wall, and strutureless fluffy meshwork of possible very fine filament.

  • PDF

PT, PZ와 PZT나노튜브의 졸-겔 형판합성과 특성 (Sol-Gel Template Synthesis and Characterization of PT, PZ and PZT Nanotubes)

  • 장기석
    • 대한화학회지
    • /
    • 제46권3호
    • /
    • pp.242-251
    • /
    • 2002
  • 졸-겔 형판 합성법을 이용하여 페로브스카이트 구조를 갖는 나노튜브를 합성하고 그 특성을 조사하였다. PbTiO3(PT), PbZrO3(PZ)와 PbZrO3-PbTiO3(PZT)고용체 나노튜부는 반응물, Ti(OPri)4, Zr(OBu)3와 Pb(OAc)2-3H2O 들의 킬레이트 졸-겔 합성법에 의해서 합성하였다. 산화 알루미늄 형판은 200nm의 직경을 갖는 훠트만 아노디스크가 사용되었다. 6.0M-NaOH 용액에서 형판을 제거한 다음, 주사현미경 분석에 의해서 50m 길이와 200nm 외곽 직경의 생성물 나노튜브를 확인할 수 있었다. 투과현미경 분석과 전자회절 분석에 의하여 나노튜브가 다결정임을 확인하였다. DSC 분석에 의하여 PT 나노튜브의 상전이 온도는 특이하게도 234.4$^{\circ}C$ 임이 확인되었으며, 이때의 입자크기는 X-선 분석의 하나인 Scherrer 식에 의해서 15.4nm 임이 계산되었다.

Seismic behavior of stiffened concrete-filled double-skin tubular columns

  • Shekastehband, B.;Mohammadbagheri, S.;Taromi, A.
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.577-598
    • /
    • 2018
  • The imperfect steel-concrete interface bonding is an important deficiency of the concrete-filled double skin tubular (CFDST) columns that led to separating concrete and steel surfaces under lateral loads and triggering buckling failure of the columns. To improve this issue, it is proposed in this study to use longitudinal and transverse steel stiffeners in CFDST columns. CFDST columns with different patterns of stiffeners embedded in the interior or exterior surfaces of the inner or outer tubes were analyzed under constant axial force and reversed cyclic loading. In the finite element modeling, the confinement effects of both inner and outer tubes on the compressive strength of concrete as well as the effect of discrete crack for concrete fracture were incorporated which give a realistic prediction of the seismic behavior of CFDST columns. Lateral strength, stiffness, ductility and energy absorption are evaluated based on the hysteresis loops. The results indicated that the stiffeners had determinant role on improving pinching behavior resulting from the outer tube's local buckling and opening/closing of the major tensile crack of concrete. The lateral strength, initial stiffness and energy absorption capacity of longitudinally stiffened columns with fixed-free end condition were increased by as much as 17%, 20% and 70%, respectively. The energy dissipation was accentuated up to 107% for fixed-guided end condition. The use of transverse stiffeners at the base of columns increased energy dissipation up to 35%. Axial load ratio, hollow ratio and concrete strength affecting the initial stiffness and lateral strength, had negligible effect of the energy dissipation of the columns. It was also found that the longitudinal stiffeners and transverse stiffeners have, respectively, negative and positive effects on ductility of CFDST columns. The conclusions, drawn from this study, can in turn, lead to the suggestion of some guidelines for the design of CFDST columns.