• Title/Summary/Keyword: outdoor air

Search Result 970, Processing Time 0.03 seconds

Microbial Metagenome of Airborne Particulate Matter: Methodology, Characteristics, and Influencing Parameters (대기입자상물질의미생물메타게놈: 분석방법, 특성및영향인자)

  • Kang, Sookyung;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.2
    • /
    • pp.165-192
    • /
    • 2022
  • The microbial metagenome characteristics of bioaerosols and particulate matter (PM) in the outdoor atmospheric environment and the effects of climate and environmental factors on the metagenome were analyzed. The concentrations of bacteria and fungi in bioaerosols and PM were determined by sampling different regions with different environmental properties. A variety of culture-independent methods were used to analyze the microbial metagenome in aerosols and PM samples. In addition, the effects of meteorological and environmental factors on the diversity and metagenomes of bacteria and fungi were investigated. The survival, growth, and dispersal of the microorganisms in the atmosphere were markedly affected by local weather conditions and the air pollutant concentration. The concentration of airborne microorganisms increased as the temperature increased, but their concentration decreased in summer, due to the effects of high temperatures and strong ultraviolet rays. Humidity and microbial concentration were positively correlated, but when the humidity was too high, the dispersion of airborne microorganisms was inhibited. These comprehensive data on the microbial metagenome in bioaerosols and PM may be used to understand the roles and functions of microorganisms in the atmosphere, and to develop strategies and abatement techniques to address the environmental and public health problems caused by these microorganisms.

Experimental Performance Validation of an Unmanned Surface Vessel System for Wide-Area Sensing and Monitoring of Hazardous and Noxious Substances (HNS 광역 탐지 및 모니터링을 위한 부유식 무인이동체 시스템의 실험적 성능 검증)

  • Jinwook Park;Jinsik Kim;Jinwhan Kim;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.11-17
    • /
    • 2022
  • In this study, we address the development of a floating platform system based on a unmanned surface vessel for wide-area sensing and monitoring of hazardous and noxious substances (HNSs). For long endurance, a movable floating platform with no mooring lines was used and modified for HNS sensing and monitoring. The floating platform was equipped with various sensors such as optical and thermal imaging cameras, marine radar, and sensors for detecting HNSs in water and air. Additionally, for experiment validation in real outdoor environments, a portable gas-exposure system (PGS) was built and installed on the monitoring system. The software for carrying out the mission was integrated with the Robot Operating System (ROS) framework. The practical feasibility of the developed system was verified through experimental tests conducted in inland water and real-sea environments.

Indoor PM2.5 Concentration Distribution and Health Risk Assessment according to the Implementation of a Seasonal Management System (미세먼지 계절관리제 시행 여부에 따른 실내 PM2.5 농도 분포 및 노출에 따른 건강위해성 평가)

  • Shin-Young Park;Dann-Ki Yoon;Hyeok Jang;Sung Won Yoon;Cheol-Min Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.4
    • /
    • pp.218-227
    • /
    • 2023
  • Background: Since 2019, the Ministry of Environment has implemented a seasonal fine dust management system from December to March, targeting high PM2.5 levels with the aim of reducing PM2.5 concentrations and protecting public health. The focus of improving the seasonal management system lies in the atmospheric PM2.5 levels. Considering the primary goal of protecting public health, it is necessary to analyze the policy effects from an exposure perspective rather than a concentration-based approach. Objectives: This study aims to quantitatively assess the improvement of indoor PM2.5 levels and the health impacts of the seasonal management system by comparing the periods before and during its implementation in residential environments. Methods: PM2.5 concentrations within residential environments in a metropolitan area were measured using an optical particle counter (IAQ-C7, K-weather, Ltd, Korea) at one-minute intervals during the pre-implementation period (November 21~25, 2022) and during the implementation period (December 19~23, 2022). Based on the measured PM2.5 concentrations, a quantitative evaluation of cancer and mortality risks was conducted according to age and gender. Results: The results of comparing indoor and outdoor PM2.5 concentrations before and during the implementation of the seasonal management system showed a decrease of approximately 56.6% and 47.9%, respectively. Health risk assessments revealed that both the safety-limit-based and safety-target-based Hazard Quotients (HQ) exceeded the threshold of 0.1 for children under 19 years of age, both before and after the implementation. The mortality risk decreased by approximately 47.9% after the implementation, with children aged 0-9 showing the highest mortality risk at 0.9%. Conclusions: The findings of this study confirmed the positive health impacts of the seasonal management system across all age groups, particularly children under 19 who are more vulnerable to fine dust exposure.

Numerical and experimental investigations on the aerodynamic and aeroacoustic performance of the blade winglet tip shape of the axial-flow fan (축류팬 날개 끝 윙렛 형상의 적용 유무에 따른 공기역학적 성능 및 유동 소음에 관한 수치적/실험적 연구)

  • Seo-Yoon Ryu;Cheolung Cheong;Jong Wook Kim;Byeong Il Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.103-111
    • /
    • 2024
  • Axial-flow fans are used to transport fluids in relatively low-pressure flow regimes, and a variety of design variables are employed. The tip geometry of an axial fan plays a dominant role in its flow and noise performance, and two of the most prominent flow phenomena are the tip vortex and the tip leakage vortex that occur at the tip of the blade. Various studies have been conducted to control these three-dimensional flow structures, and winglet geometries have been developed in the aircraft field to suppress wingtip vortices and increase efficiency. In this study, a numerical and experimental study was conducted to analyze the effect of winglet geometry applied to an axial fan blade for an air conditioner outdoor unit. The unsteady Reynolds-Averaged Navier-Stokes (RANS) equation and the FfocwsWilliams and Hawkings (FW-H) equation were numerically solved based on computational fluid dynamics techniques to analyze the three-dimensional flow structure and flow noise numerically, and the validity of the numerical method was verified by comparison with experimental results. The differences in the formation of tip vortex and tip leakage vortex depending on the winglet geometry were compared through a three-dimensional flow field, and the resulting aerodynamic performance was quantitatively compared. In addition, the effect of winglet geometry on flow noise was evaluated by numerically simulating noise based on the predicted flow field. A prototype of the target fan model was built, and flow and noise experiments were conducted to evaluate the actual performance quantitatively.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

A Study of Detainees' Perceptions of the Detention Facilities of the Police Station and their Operation (경찰서 유치장 시설 및 운영에 관한 유치인의 인식연구)

  • Jung, Woo-Yeoul;Park, Dong-Kyun;Kim, Do-Kyun
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.423-449
    • /
    • 2007
  • This research is to investigate the detention facilities of police stations and their real operations through the perceptions of detainees at police station cells and to present the policy suggestions for them. To fulfill the research, a questionnaire was made out on the basis of 'the Regulation on Detention and Escort for Suspects'. 'the Regulation on a Standard Plan for Detention Facilities' and 'the Regulation on the Lowest Standard to Treat Detainees' ; and detainees at 23 police station cells under the jurisdiction of Kyungbuk Local Police Agency were asked to answer it. Policy suggestions following from the result of the investigation of detainees' perceptions of the detention facilities of the police stations are as follows; Firstly, the structure of police station cells should be arranged in straight lines in order to take their human rights into consideration and more detention facilities are needed to be built in order to separate male, female, handicapped and juvenile inmates. Secondly, shower rooms and washrooms outside the cells should always be open to detainees whenever they need to be used. Thirdly, any detention facilities deficient in fire fighting equipment should have exit doors installed as soon as possible in case of an emergency and provide sufficient fire extinguishers considering the number of detainees and the size of the facilities. Fourthly, the detention facilities should have sufficient windows for ventilation and take necessary measures to obtain natural lighting instead of electric lighting. Fifthly, air conditioners should be equipped properly taking account of the number of detainees and the dimensions of the facilities. Policy suggestions according to the result of the investigation of detainees' perceptions of the operation of detention facilities of police stations are as follows; Firstly, the problem of operating the detention facilities must deal with worn-out facilities and measures to secure the budget should be taken as soon as possible. Secondly, considering that most detained suspects have difficulties in livelihood, daily necessaries must be issued to them. Thirdly, personal belongings deposited by inmates must be properly managed with the same documentation throughout the police station detention facilities. The number of female guards to take exclusive charge of the physical checkups and processing of female detainees should be increased. Also the facilities for handicapped detainees must be expanded, improved and managed properly. Fourthly, except for handcuffs and ropes to bind detainees in the detention facilities, helmets to prevent self-harm must be withdrawn. The budget to improve the quality of meal issued by the government must be urgently secured and the price of private food sent to detainees must be readjusted to be in line with the consumer price. Health and medical care and sanitation for detainees must be substantial, and also sunbathing and outdoor exercises should be allowed to detainees.

  • PDF

Conservation State of Mural Paintings of Royal Tombs in Neungsan-ri, Korea (능산리고분군 동하총 벽화 보존상태 진단)

  • Lee, Sang Ok;Bae, Go Woon;Namgung, Hun;Nam, Do Hyeon;Choi, Yoon Gwan;Chung, Kwang Yong
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.333-343
    • /
    • 2018
  • This study was conducted to evaluate the conservation environment by monitoring temperature and humidity for two years and mapping the remaining pigments of mural paintings to diagnose the conservation state of mural paintings of Royal Tombs in Neungsan-ri. We evaluated the characteristics of condensation in the tomb. Compared with the results of a 2008 survey, we conducted state change of mural paintings in the tomb. The temperature in the main room, which has an annual average soil temperature distribution at 5 m depth in Korea, is maintained at $13{\sim}18^{\circ}C$. The temperature range of the main room was between less than $0.1^{\circ}C$ to $0.5^{\circ}C$, and the diurnal variation of temperature between summer (June to September) and winter (December to January) is the greatest. Condensation is more concentrated in the summer because the outdoor air was typically at higher temperatures than the main room inflows in the tomb. Mapping the remaining pigment composition and particle distribution of mural paintings showed that it was in the range of 36.72~39.53% of the wall area. The pigment range was confirmed to be the same as it was in 2008, through ultraviolet fluorescence reaction and infrared ray investigation. Therefore, the underground environment that receives dew condensation in the summer has been stable since 2008. However, continuous monitoring is needed because the deterioration of mural painting proceeds considerably after excavation and only a small percentage of the pigments survive.

Relativeness between Growth and Bio-informations of Aeroponically Grown Tomato as Influenced by Spray Intervals of Nutrient Solution (양액의 분무간격에 따른 분무경재배 토마토의 생장 및 생체정보와의 관련성)

  • 정순주;소원온;지전영남;영목방부
    • Journal of Bio-Environment Control
    • /
    • v.1 no.2
    • /
    • pp.154-161
    • /
    • 1992
  • This experiment was carried oui to determine the relativeness between growth, yield characters and bio-informations as influenced by the spray and rest time intervals of nutrient solution. Tomato(Lycopersicon esculentum Mill.) were grown in aeroponic system on a misting schedule of continuously 60 sec, 30 sec and 10 sec at 10 min intervals with full strength Yamazaki's solution recommended for tomato production. The results obtained were as follows : 1. Leaf area was highest in the plot of 30 sec spray and 10 min rest while the forest one was the plot of 60 sec spray and 10 min rest. Growth characteristics in terms of dry weight of each organ, number of flower, number of flower setted and fruit dry weight were greater in the plot of 30 sec spray and 10 min rest than the other treatments. 2. The number of flower increased with decreasing dry weight but number of flower sorted was not significantly different among treatment except for the plot of 60 sec spray and 10 min rest. 3. Leaf dry weight and fruit dry weight were highly correlated so that 30 sec spray and 10 min rest plot which is the highest fruit dry weight showed the largest leaf area. Continuously sprayed plot reduced markedly the fruit dry weight compared with leaf area. Optimum spray and rest time of nutrient solution in the range of this experiment was determined as 30 sec spray and 10 min rest. 4. Solar radiation within glasshouse during daytime reduced severely compared with outdoor one and air temperature within greenhouse was higher than the leaf temperature of tomato plant. The changes of environmental factors, solar radiation, temperature were accompanied with the sensitive change of bio-informations of tomato leaf Especially differences of spray intervals of nutrient solution affected greatly to the changes of bio-informations : leaf water potential, stomatal resistance and leaf temperature etc. 5. The changing patterns of leaf growth as influenced by the spray and rest intervals of nutrient solution were closely related to the leaf water potential, stomatal resistance and leaf temperature. Feasibility was demonstrated that measurement of bio-information of tomato leaf as influenced by the change of environmental factors could be expected to the amount of growth and fruit yield.

  • PDF

Experimental Study on the Characteristics of Ground Heat Exchange in Heating Greenhouses (난방 온실의 지중열 교환 특성에 관한 실험적 연구)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • The calculation method of ground heat exchange in greenhouses has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the soil temperature distribution and the soil heat flux in three plastic greenhouses of different size and location during the heating period. And then the calculation methods of ground heat exchange in greenhouses were reviewed. The soil temperature distributions measured in the heating greenhouse were compared with the indoor air temperature, the results showed that soil temperatures were higher than room temperature in the central part of greenhouse, and soil temperatures were lower than room temperature in the side edge of greenhouse. Therefore, it is determined that the ground heat gain in the central part of greenhouse and the perimeter heat loss in the side edge of greenhouse are occurred, there is a difference depending on the size of greenhouse. Introducing the concept of heat loss through the perimeter of building and modified to reflect the size of greenhouse, the calculation method of ground heat exchange in greenhouses is considered appropriate. It was confirmed that the floor heat loss measured by using soil heat flux sensors increased linearly in proportion to the temperature difference between indoor and outdoor. We derived the reference temperature difference which change the direction of ground heat flow and the perimeter heat loss factor from the measured heat flux results. In the heating design of domestic greenhouses, reference temperature differences are proposed to apply $12.5{\sim}15^{\circ}C$ in small greenhouses and around $10^{\circ}C$ in large greenhouses. Perimeter heat loss factors are proposed to apply $2.5{\sim}5.0W{\cdot}m^{-1}{\cdot}K^{-1}$ in small greenhouses and $7.5{\sim}10W{\cdot}m^{-1}{\cdot}K^{-1}$ in large greenhouses as design standard data.

Analysis of Thermal Environment Modification Effects of Street Trees Depending on Planting Types and Street Directions in Summertime Using ENVI-Met Simulation (ENVI-Met 시뮬레이션을 통한 도로 방향별 가로수 식재 형태에 따른 여름철 열환경 개선 효과 분석)

  • Lim, Hyeonwoo;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.1-22
    • /
    • 2022
  • The modification effects of street trees on outdoor thermal comfort in summertime according to tree planting types and road direction were analyzed using a computer simulation program, ENVI-met. With trees, the air temperature and wind speed decreased, and the relative humidity increased. In the case of mean radiant temperature (Tmrt) and human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI), there was a decrease during the daytime. The greatest change among the meteorological factors by trees happened in Tmrt, and PET and UTCI showed similar patterns with Tmrt·The most effective tree planting type on thermal comfort modification was low tree height, wide tree crown, high leaf area index, and narrow planting interval (LWDN). Tmrt, PET and UTCI showed a large difference depending on shadow patterns of buildings and trees according to solar altitude and azimuth angles, and building locations. When the building shade areas increased, the thermal modification effect by trees decreased. In particular, results on the east and west sidewalks showed a large deviation over time. When applying the LWDN, the northwest, west and southwest sidewalks showed a significant reduction of 8.6-12.3℃ PET and 4.2-4.5℃ UTCI at 10:00, and the northeast, east and southeast sidewalks showed 8.1-11.8℃ PET and 4.4-5.0℃ UTCI at 16:00. On the other hand, when the least effective type (high tree height, narrow tree crown, low leaf area index, and wide planting interval) was applied, the maximum reduction was up to 1.8℃ PET and 0.9℃ UTCI on the eastern sidewalks, and up to 3.0℃ PET and 0.9℃ UTCI on the western ones. In addition, the difference in modification effects on Tmrt, PET and UTCI between the tree planting types was not significant when the tree effects were reduced by the effects of buildings. These results can be used as basic data to make the most appropriate street tree planting model for thermal comfort improvement in urban areas in summer.