• 제목/요약/키워드: out gas

검색결과 4,016건 처리시간 0.034초

Comparative studies of gasification potential of agro-waste with wood and their characterization

  • Tripathi, Amarmani;Shukla, S.K.
    • Advances in Energy Research
    • /
    • 제3권3호
    • /
    • pp.181-194
    • /
    • 2015
  • In this work, an experimental study of the gasification on wood was carried out in downdraft type fixed bed Gasifier attached with 10 kW duel fuel diesel engine. The main objective of the study was to use wood as the biomass fuel for downdraft Gasifier and to evaluate the operating parameter of gasifier unit to predict its performance in terms of gas yield and cold gas efficiency. The influence of different biomass on fuel consumption rate, gas yield and cold gas efficiency was studied. Composition of producer gas was also detected for measuring the lower heating value of producer gas to select the feed stock so that optimum performance in the existing gasifier unit can be achieved. Under the experimental conditions, Lower heating value, of producer gas, cold gas efficiency and gas yields, using wood as a feed stock, are $4.85MJ/m^3$, 46.57% and $0.519m^3/kg$.

마우스(mouse)를 이용한 건축물 마감재료 연소가스 SO2의 독성생체지표 연구 (A Study on Toxicity Bio-markers of a Mouse using Combustion Gas SO2 generated from Fire)

  • 이동호;조남욱;최순영
    • 대한안전경영과학회지
    • /
    • 제14권1호
    • /
    • pp.43-51
    • /
    • 2012
  • This study was carried out to observe the impacts of a mouse's inhalation of toxic gas SO2 generated from combustion on its organs by different concentrations. As for research methods: First, after concentrations of SO2 generation from combustion had been set to three: low (10.4 ppm), middle (24.9 ppm) and high (122 ppm) through Gas Toxicity Testing Method (KS F 2271) and SO2 combustion gas was exposed to eight mice in each concentration. Five mice that were able to move based on LD50, a criterion, which sets the down time of a mouse's average behaviors to over 9 minutes, were randomly selected in each concentration, and they were set up as the subjects of the study on toxicity bio-markers. Second, tissues were taken from heart, liver, lungs, spleen and the thymus gland of the mice selected in each concentration and a pathological examination of them was carried out. As a result, microvascular congestion appeared in the heart, and cell necrosis, cortex congestion and tubule medulla congestion, etc. in each concentration were observed in addition to vascular congestion in liver, lungs, spleen and the thymus gland. Also, it was found that the higher the concentrations of SO2 exposure is, the greater, the changes in the organs get. Through this study, SO2 of various toxic gases generated from fire turned out to affect the tissues of each organ of a mouse, it is expected that the toxic gases may greatly affect human body in case of actual fire, and this study is evaluated as having a significance as a basic data on inhalation toxicity assessment of toxic substances generated in combustion.

공정열교환기 소형 시제품에 대한 고온구조해석(III) (High-temperature Structural Analysis of Small-scale Prototype of Process Heat Exchanger (III))

  • 송기남;이형연;김찬수;홍성덕;박홍윤
    • 대한기계학회논문집A
    • /
    • 제35권2호
    • /
    • pp.191-200
    • /
    • 2011
  • 초고온가스로로부터 생성된 $950^{\circ}C$ 정도의 초고온 열을 이용하여 수소를 경제적이며 또한 대량으로 생산하는 원자력수소생산시스템에서 공정열교환기는 초고온 열과 화학반응 공정을 통해 수소를 생산하기 위한 핵심 기기이다. 한국원자력연구원에서는 초고온가스로에 사용될 기기에 대한 성능시험을 위해 소형가스루프를 구축하고 공정열교환기 시제품을 수정 제작하였다. 본 연구는 공정열교환기 수정 시제품을 소형가스루프에서 시험하기 전에 루프 시험조건하에서 공정열교환기 수정 시제품의 고온 구조건전성을 미리 평가하기 위한 작업의 일환으로 공정열교환기 수정 시제품에 대한 고온 구조해석 모델링, 거시적 열 해석 및 구조 해석을 수행하고 그 결과들을 정리한 것이다. 해석 결과는 공정열교환기 수정 시제품 성능시험 장치 설계에 반영할 것이다.

SF6 가스 절연변압기의 절연특성과 부분방전 (Insulation Characteristics and Partial Discharge for the SF6 Gas Insulated Transformer)

  • 선종호;김우성;김광화;오원근;하영식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.740-747
    • /
    • 2000
  • This paper describes insulation characteristics and partial discharge for the SF6 gas insulated transformer. The characteristic of gas insulated transformer and the degradation sequence of solid insulation under SF6 gas atmosphere were explained. The model electrode system of the types that the aramid papers were inserted between two sphere electrodes was prepared. The partial discharge tests were carried out to that system and the insulation characteristics were considered.

  • PDF

Gas Chromatography에 의한 인체혈액중에서 스미치온 및 마라치온의 분리정량에 관한 연구 (A Study on the Isolative determination of Smithion and Malathion in the Human Blood by Gas Chromatography)

  • 구성회;박성우;이영자
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.58-60
    • /
    • 1978
  • This experiment was carried out to determine the amount of organophosphorous pesticides accumulated in farmer's blood during the farming season. The Blood had been collected for about 5ml from farmer's, and extraction was purified on a Avicel/Darco G-Co (1:10) column and determined by Gas Chromatography using AFID supported on 2% EGA. The Gas chromatographic detection yielded recoveries from the blood of 88% for smithion 94% for malathion. The amount of average contamination shows 0.045ppm for smithion. 0.054ppm for malathion.

  • PDF

Precipitation of Manganese in the p-Xylene Oxidation with Oxygen-Enriched Gas in Liquid Phase

  • Jhung, Sung-Hwa;Park, Youn-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.369-373
    • /
    • 2002
  • The liquid phase oxidation of p-xylene has been carried out with oxygen-enriched gas, and the manganese component was precipitated probably via over-oxidation to $Mn^{4+}$. The precipitation increased with rising oxygen concentration in the reaction gas and occurred mainly in the later part of the oxidation. The activity of the reaction decreased, and the blackening of the product and side reactions to carbon dioxide increased with the degree of precipitation. Precipitation can be decreased with the addition of metal ions, such as cerium, chromium and iron.

A Presentation of a Cost Classification System for Gas Plant Construction Projects

  • Park, Moonsun;Kim, Yongsu
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.625-626
    • /
    • 2015
  • The purpose of this study is to present a cost classification system that can be used in gas plant construction projects. Towards this end, it examined the detailed statements of the construction companies which had experience in carrying out plant construction projects. Based on the above, it also presented a life-cycle (i.e., EPCC) cost classification system for the gas plant construction projects by conducting the Delphi analysis through the expert opinions.

  • PDF

이온화가스와 활성탄을 이용한 휴믹산 처리에 관한 연구 (The Humic Acid Treatment Characteristics by Ionized Gas and Combination with Activated Carbon)

  • 정팔진;이은주;김민정;조선영
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.72-77
    • /
    • 2004
  • Laboratory studies were carried out to find out the characteristics of humic acid treatment by activated carbon and ionized gas, In order to increase oxidation power of ionized gas for treating organic matter, we used granular activated carbon. By using $UV_{254}$, easy analysis method, we calculated humic acid concentration and $SCOD_{cr}$ concentration. For an initial concentration of humic acid, 10, 50 and 100ppm, the reaction rate constant by $UV_{254}$ was $8.98{\times}10^{-3}$/min, $5.62{\times}10^{-3}$/min and $4.8{\times}10^{-3}$/min respectively due to the same flow rate of ionized gas. When we added activated carbon to the ionized gas for humic acid treatment, the reaction rate constant increased in 4.13, 3.65 and 3.15 times. So, by using activated carbon in treating humic acid by ionized gas, oxidation power of organic matter by ionized gas was increased. The hydrophobic fraction constitutes 98% of organic matter for humic acid at the beginning. After the treatment using ionized gas for humic acid, the hydrophobic fraction decreased by 63~65% and the hydrophilic one increased by 35~37%. So, it was proved that the treatment increased the hydrophilic fraction in organic matter.

모델링 기술을 이용한 심해 Gas Hydrate의 탄성파 특성 연구 (Seismic properties of Gas Hydrate using Modeling Technique)

  • 신성렬;여은민;김찬수;김영준;박근필;이호영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.156-157
    • /
    • 2005
  • Gas hydrate is ice-like crystalline lattice, formed at appropriate temperature and pressure, in which gas molecules are trapped. It is worldwide popular interesting subject as a potential energy. In korea, a seismic survey for gas hydrate have performed over the East sea by the KIGAM since 1997. In this paper, we had conducted numerical and physical modeling experiments for seismic properties on gas hydrate with field data which had been acquired over the East sea in 1998. We used a finite difference seismic method with staggered grid for 2-D elastic wave equation to generate synthetic seismograms from multi-channel surface seismic survey, OBC(Ocean Bottom Cable) and VSP(Vertical Seismic Profiling). We developed the seismic physical modeling system which is simulated in the deep sea conditions and acquired the physical model data to the various source-receiver geometry. We carried out seismic complex analysis with the obtained data. In numerical and physical modeling data, we observed the phase reversal phenomenon of reflection wave at interface between the gas hydrate and free gas. In seismic physical modeling, seismic properties of the modeling material agree with the seismic velocity estimated from the travel time of reflection events. We could easily find out AVO(Amplitude Versus Offset) in the reflection strength profile through seismic complex analysis.

  • PDF

과학위성1호 비행모델 Bake-Out 시험결과 분석

  • 조혁진;서희준;이상훈;조창래;문귀원;최석원
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.45-49
    • /
    • 2003
  • 한국항공우주연구원 위성시험동에 설치된 Bake-Out 챔버를 통하여 과학위성 1호 비행모델(STSAT-1FM)에 대한 Bake-Out 시험이 수행되었다. 본 시험은 시험 후에 장착될 FIMS라는 광학장비에 영향을 미칠 Outgassing Rate의 측정 및 고온에서의 Bake-Out을 통한 오염물질 제거에 목적을 둔 시험으로 총 10일여 동안 시험이 수행되었다. Honeycomb Panel 및 Harness에 대한 시험(Batch 1), 조립된 비행모델에 대한 Bake-Out(batch 2), 그리고 part별로 펼쳐진 상태로의 Bake-Out 시험(Batch 3), 총 세 번의 시험으로 이루어졌다. 각각의 시험에 대하여 TQCM(Thermoelectric Quartz Crystal Microbalance) 및 RGA(Residual Gas Analyzer)를 통하여 Outgassing 물질에 대한 정량적, 정성적 측정 및 분석이 이루어졌다.

  • PDF