• Title/Summary/Keyword: orthodontics

Search Result 2,701, Processing Time 0.027 seconds

The Effect of Tin Ion-plating on the Bond Strength of Orthodontic Bracket (TiN Ion-Plating이 교정용 브라켓의 접착강도에 미치는 영향)

  • KIM, Seok-Yong;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.157-171
    • /
    • 1997
  • This study was conducted to see the effect of TiN ion-plating on the bond strength of orthodontic bracket. Three stainless-steel brackets with different base types were chosen; when TiN ion-plated brackets and non iorrplated brackets were bonded to the teeth, initial and long-term bond strength were measured, The observations oi bonding surface and failure sites through the scanning electron microscope were analysed and compared. The summary of this study was as follows; ${\cdot}$ When TiN ion-plating was not applied, the Micro-Loc type was the highest in bond strength atter 24 hours as $5.89{\pm}1.77$ MPa, followed by $4,27{\pm}1.12MPa$ for Foil Mesh type and $2.64{\pm}0.58MPa$ for Undercut type(P<0.05). ${\cdot}$ Under TiN ion-plating, the bond strength after 24 hours showed: Micro-Loc type $-6.26{\pm}1.51MPa$, Foil Mesh type $-7.45{\pm}2.01MPa$, Undercut type $-2.93{\pm}0.84MPa$. Unlike in the case of non ion-plating, Foil Mesh type showed a higher strength than Micro-Loc type, with Undercut type still showing the lowest bond strength(P<0.05). The bond strength, after 24 hours, increased in case of ion-plated in all 3 types, but a significant increase was shown only in Foil Mesh type(P<0.001). ${\cdot}$ Under a long-term immersion, regardless of ion or non ion-plating, bond strength in general increased over the initial bond strength(one day), with more stability. ${\cdot}$ Through scanning electron microscopic observation of bonding surface, it was found that, regardless of the bracket base type or the application of ion-plating, the resin was thoroughly spreaded into bracket base to form a solid bonding surface between the bracket and the tooth. This was also true in case of a long-term immersion. ${\cdot}$ The scanning electron microscopic observation of failure sites revealed diverse failure patterns.

  • PDF

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

Changes in occlusal force depending on the movement of the adjacent and opposing teeth after loss of lower first molar: comparative study by using a strain gauge (하악 제1대구치 상실 시 인접 및 대합 치아들의 이동양상에 따른 교합력 변화: 스트레인게이지를 이용한 비교 연구)

  • Song, Myoung-Ja;Park, Ji-Man;Chun, Youn-Sic
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.47-59
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the changes in occlusal force after loss of the lower first molar depending on the inclination and extrusion of the adjacent and opposing teeth by using a strain gauge. Materials and Methods: Anatomic teeth were used to reconstruct the normal dental arch with loss of the lower right first molar. A uniformly thick layer of silicone was applied to the root to mimic the periodontal ligament. Four stages of dies with varying degrees of inclination and extrusion of the adjacent and opposing teeth were constructed and attached to master model interchangeably by using a CAD/CAM fabricated customized die system. The strain gauges were attached to teeth and a universal testing machine was used to determine the changes in occlusal force. An independent t-test and one-way ANOVA were performed (${\alpha}=.05$). Results: While simulating chewing food, the upper first, second premolar and lower second molar showed greater occlusal force than before extraction. When the change of adjacent teeth's occlusal force with their progressive movement after molar loss was evaluated, the difference among four die models was significant and was in the decreasing aspect (P < 0.05). Conclusion: When the lower first molar was lost and the adjacent teeth did not move yet, the occlusal force in adjacent teeth was higher than that when the lower first molar still existed. In addition, the occlusal force in the upper premolars and lower second molar decreased significantly with the progressive movement of adjacent teeth.

Positional Changes of the Internal Reference Points Followed by Reposition of the Maxilla - A Study of a 3D Virtual Surgery Program (상악골 재위치술 시행 시 골편의 이동량에 따른 내측기준점의 변화 - 3차원 가상수술 프로그램을 이용한 연구)

  • Suh, Young-Bin;Park, Jae-Woo;Kwon, Min-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.413-419
    • /
    • 2011
  • Purpose: Reposition of the maxilla is a common technique for correction of midfacial deformities. To achieve the goal of the surgery, the maxilla should be repositioned based on the precisely planned position during surgery. The internal reference points (IRPs) and the external reference points (ERPs) are usually used to determine vertical dimension of maxilla, which is an important factor for confirming maxillary position. However, the IRPs are known to be inaccurate in determining the vertical dimension. In this study, we investigated the correlation of positional change of the modified IRPs with repositioned maxilla. Methods: The study group consisted of 26 patients with dentofacial deformities. For the simulation of the surgery, patient maxillary CT data and 3-D virtual surgery programs (V-$Works^{(R)}$ and V-$Surgery^{(R)}$) were used. IRPs of this study were set on both the lateral wall of piriform aperture, inferior margin of both infraorbital foramen, and the labial surfaces of the canine and first molar. The distance from the point on lateral wall of the piriform aperture to the point on the buccal surface of the canine was defined as IRP-C, and the distance from the point on the inferior margin of the infraorbital foramen to the point on the buccal surface of the $1^{st}$ molar was defined as IRP-M. After the virtual simulation of Le Fort I osteotomy, the changes in IRP-C and IRP-M were compared with the maxillary movement. All measures were analyzed statistically. Results: With respect to vertical movements, the IRP-C (approximately 98%) and the IRP-M (approximately 96%) represented the movement of the canine and the $1^{st}$ molar. Regarding rotating movement, the IRPs changed according to the movement of the canine and the $1^{st}$ molar. In particular, the IRP-C was changed in accordance with the canine. Conclusion: IRPs could be good indicators for predicting vertical movements of the maxilla during surgery.

An Anatomical Study using CT Images for the Implantation of Micro-implants (CT 이미지를 사용한 Micro-implants 식립을 위한 매부학적 연구)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.435-441
    • /
    • 2002
  • Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.

Clinical Effects and Stability of the Maxillary Protraction Using the Lateral Cephalogram in Korean (상악골 전방견인 장치의 효과와 안정성에 대한 두부방사선 계측학적 연구)

  • Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.509-529
    • /
    • 1992
  • Skeletal Class III malocclusion is one of the most difficult type to treat and stabilize. For a child with developing skeletal Class III malocclusion, the treatment objective would be to stimulate maxillary growth, particulary one who has markedly deficient maxilla, and to restrain excessive mandibular growth. In order to stimulate the maxillary growth, maxillary protraction appliance is the one of the effective orthopedic appliances in skeletal Class III. The purposes of this study were as follows ; evaluation of the skeletal and dental changes of the maxillary protraction in children with Class III Maxillary deficiency , comparison of the clinical effects between the group with RPE and labiolingual intraoral appliances , comparison of the clinical effects and stability related to the ages of the patients : stability of the maxillary protraction about 1 year after retention. The subjects consisted of 60 children between the ages of 8 and 13.4 who were diagnosed as Class III with maxillary deficiency and were treated with Face Mask (Delaire Type) from the Dept. of Orthodontics Yong Dong Severance Hospital, Yonsei University. 48 children wore the RPE and 12 children wore Labiolingual Appliance. Lateral Cephalograms were taken for each patient at before and after correction of anterior cross-bite in 60 children, and after an observation period of 10 to 14 months in 19 children. X and Y coordinate of 10 landmarks were analyzed using a horizontal line through sella and rotated $6^{\circ}$ down anteriorly as the horizontal reference axis, and a perpendicular verticual line through sella as the vertical reference axis. Each of the 31 measurents (10 verticals, 10 horizontals, 2 angles and 9 others) was statistically analyzed using SPSS/PC statistics. The results are as follows; 1. After maxillary protraction the maxilla and maxillary teeth moved downward and forward, while the mandible and mandibular incisor rotated downward and backward. 2. Maxillary protraction with rapid palatal expansion appliance was more effective than with labiolingual appliance. 3. More downward movement of the posterior palatal plane obserbed with maxillary protraction doing the midpalatal suture opening than with protraction after finishing the palatal expansion 4. The clinical effects of protraction and changes of the retention periods were not statistically significant among the age groups. 5. During the retention period, maxilla and maxillary teeth, and mandible and mandibular teeth moved downward and forward, however the mandibular changes were larger than the maxillary changes.

  • PDF

A study on the bone thickness of midpalatal suture area for miniscrew insertion (미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구)

  • Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.63-70
    • /
    • 2004
  • The midpalatal suture area has some advantages for supporting miniscrews : it has no specific anatomical structure, it is composed of thick cortical bone, and covered with attached gingiva. So it is suitable area for inserting miniscrews. However, the midpalatal suture area appears thinner when seen in ceph. As a result, Clinicians can misunderstand that inserting miniscrews cause the problem, both the risk of perforation and the decrease of stability. The purpose of this article is measuring the vertical bone thickness of the midpalatal suture area for inserting miniscrews. The total of 25patient (male : 13, female : 12), who are in their twenties, were taken CT. The vertical bone thickness of the midpalatal suture area was measures from the transverse section of CT. As a result, We reached a conclusion from the differences of each area. It is as follows: 1. There is no significant difference between the thickness of male group and that of female group. 2. In coronal section, Bone thickness becomes thinner from the midpalatal suture to Left & Right side, in sagittal section, Bone thickness becomes thinner from incisive foramen to PNS. 3. The area that is within 3mm of left and right from the midpalatal suture area transversely and within 25mm backward from the incisive foramen sagittaly is enough for inserting miniscrews.

A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE (상악견치 후방견인시 저항원 조절을 위한 MAS(Molar Anchoring Spring)의 초기 응력분포에 관한 광탄성학적 연구)

  • Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.341-348
    • /
    • 1996
  • The efficiency of maxillary canine retraction by means of sliding mechanics along an 0.016 continuous labial arch and an 0.009 inch in diameter with a lumen of 0.030 inch NiTi closed coil spring was compared with that using the same NiTi closed coil spring and Molar Anchoring Spring(MAS) which was designed by author. MAS was made of .017" X .025" TMA wire and was given 60 degree tip-back bend on the wire close to the molar tube. This study was designed to investigate molar and canine root control during retraction into an extraction site with continuous arch wire system. Two techniques were tested with a continuous arch model embedded in a photoelastic resin. A photoelastic model was employed to visualize the effects of forces applied to canine and molar by two retraction mechanics. With the aid of polarized light, stresses were viewed as colored fringes. The photoelastic overview of the upper right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows. 1. Higher concentration of compression can be seen clearly at the distal curvature of the canine and mesial curvature of the molar and premolar when NiTi closed coil spring was applied only, which means severe anchorage loss of the molar and uncontrolled tipping of the canine. 2. The least level compression was presented at the mesial root area of the molar and premolar, and mesial root area of the canine when NiTi closed coil spring and MAS were used simultaneously. Especially mesial alveolar crest region of the canine was shown moderate level of compression that means MAS can be used as a appliance for anchorage control and prevention of canine extrusion and uncontrolled tipping during canine retraction.

  • PDF

EFFECTS OF NITRIC OXIDE SYNTHASE INHIBITORS ON OSTEOCLAST-LIKE CELL FORMATION

  • Ahn, Seung-Kyu;Kim, Jung-Kun;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.715-722
    • /
    • 1995
  • Orthodontic tooth movement in response to orthodontic force results from actions of osteoclasts and osteeoblasts in the cell level. Convincing evidence has now been provided to support the view that osteoclasts are derived from mononuclear cells that originate in the bone marrow or other hematopoietic organs and they migrate to the bones via vascular routes. Nitric oxide(NO), which accounts for the biological properties of endothelium-derived relaxing factor(EDRF), is the endogenous stimulator of soluble guanylate cylase. The discovery of the formation of nitric oxide(NO) from L-arginine in mammalian tissues and its biological roles has, in the last 7 years, thrown new light onto many areas of research. Data from experiments in vitro showed that N-metyl-L-arginine(L-NMA) and L-nitro-L- arginine(L-NAME) are competitive inhibitors of nitric oxide synthase. This study suggest that the multinucleated cells in our culture have characteristics of osteoclasts and that the potential bone cell activity of nitric oxide in vitro may be mediated in part by stimulation of marrow mononuclear cells to form osteoclast-like cells. Bone marrow cells were obtaineed from tibia of 19-days old chick embryo. After sacrifice, tibia was quickly dissected and the bone were then split to expose the medullary bone. The cells were attached for 4 hours and the nonadherent cells were collected. Marrow cells weere cultured in 96-well plate in medium 199. To examine the number of TRAP-positive multinucleated cells(MNCs), $10^{-8}\;M\;Vit=D_3$ and various concentration of L-NMA and L-NAME weere added at the beginning of cultures and with each medium change. After 7 days of culture. tartrate-resistant acid phosphatase(TRAP) staining was performed for microscopic evaluation. Cells haying more than three nuclei per cell were counted as MNCs. The obsrved results were as follows;1. 1,25-dihydroxyvitamine $D_3$ stimulated the osteoclast-like multinucleated cells in cultures of chick embryo bone marrow. 2. Nitric oxide synthase inhibitors(NOSI ; N-NMA, N-NAME) stimulated the osteoclast-like cells in cultures of chick embry bone marrow. 3. 1,25-dihydroxyvitamine$D_3$ and nitric oxide synthase inhibitors did not appear to have additive effect on the generation of TRAP-positive MNCs. These results suggest that nitric oxide synthase inhibitors may stimulate the osteoclast-like multinucleated cell formation and fusion in cultures of chick bone marrow.

  • PDF

An Experimental Study on the Effect of Half Sine-Wave Pulsed Electromagnetic Field in Orthodontic Tooth Movement (Half-sine Wave Pulsed Electromagnetic Fields가 교정적 치아 이동에 미치는 영향에 관한 실험적 연구)

  • Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.157-163
    • /
    • 1999
  • The purpose of this study was to investigate the effect of electromagnetic field in orthodontic tooth movement, and the optimal application period of electromagnetic field to initiate tooth movement. Eighty male Hartley guinea pigs were utilized in this study. Laterally directed orthodontic force was applied to the maxillary central incisors. Half sine-wave pulsed electromagnetic field(HSPEMP) was applied to experimental group during 10 days. According to the period of application of HSPEMP(4 hours, 8 hours, 12 hours a day), they were divided into the three sub-groups The obtained results were as follows; 1. In case of application of HSPEMF during 4 hours a day, there was no significant difference in the final amount of orthodontic tooth movement between the experimental and the control group. 2. In case of application of HSPEMF during 8 and 12 hours a day, there was a significant increase in the final amount of orthodontic tooth movement since the eighth day, the sixth day respectively. 3. In comparison with the case of application of HSPEMF during 8 hours a day, there was a significant increase in the final amount of orthodontic tooth movement at the seventh day and the eighth day in case of application of HSPEMF during 12 hours a day.

  • PDF