• Title/Summary/Keyword: orthodontics

Search Result 2,701, Processing Time 0.021 seconds

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

Reasons influencing the preferences of prospective patients and orthodontists for different orthodontic appliances

  • Maranon-Vasquez, Guido Artemio;Barreto, Luisa Schubach da Costa;Pithon, Matheus Melo;Nojima, Lincoln Issamu;Nojima, Matilde da Cunha Goncalves;Araujo, Monica Tirre de Souza;de Souza, Margareth Maria Gomes
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.115-125
    • /
    • 2021
  • Objective: To evaluate the reasons influencing the preferences for a certain type of orthodontic appliance over another among prospective patients (PP) and orthodontists. Methods: A total of 49 PP and 51 orthodontists were asked about their preferences for the following appliances: clear aligners (CA), lingual metallic brackets (LMB), polycrystalline and monocrystalline ceramic brackets, and buccal metallic brackets (BMB). The participants rated the importance of 17 potential reasons that would explain their choices. The reasons that contributed most to these preferences were identified. Non-parametric tests (Fisher's exact, χ2 and Mann-Whitney tests) and multivariate analyses (regression and discriminant analysis) were used to assess the data (α = 0.05). Results: CA and BMB were the most chosen appliances by PP and orthodontists, respectively. LMB was the most rejected option among both groups of participants (p < 0.001). Rates of the importance of pain/discomfort, smile esthetics, finishing details, and feeding/speech impairment showed the highest differences between PP and orthodontists (p < 0.0005). Discriminant analyses showed that individuals who considered treatment time and smile esthetics as more important were more likely to prefer CA, while those who prioritized finishing details and cost were more likely to choose BMB (p < 0.05). Conclusions: Reasons related to comfort and quality of life during use were considered as more important by PP, while those related to the results and clinical performance of the appliances were considered as more relevant by orthodontists.

Evaluation of mandibular buccal shelf characteristics in the Colombian population: A cone-beam computed tomography study

  • Escobar-Correa, Natalia;Ramirez-Bustamante, Maria Antonia;Sanchez-Uribe, Luis Alejandro;Upegui-Zea, Juan Carlos;Vergara-Villarreal, Patricia;Ramirez-Ossa, Diana Milena
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.23-31
    • /
    • 2021
  • Objective: To evaluate the mandibular buccal shelf (MBS) in terms of the angulation and bone depth and thickness according to sex, age, and sagittal and vertical skeletal patterns in a Colombian population using cone-beam computed tomography (CBCT). Accordingly, the optimal site for miniscrew insertion in this area was determined. Methods: This descriptive, retrospective study included 64 hemi-arches of 34 patients. On CBCT images, the angulation, buccal bone depth (4 and 6 mm from the cementoenamel junction [CEJ] of MBS), and buccal bone thickness (6 and 11 mm from the CEJ of MBS) were measured at the mesial and distal roots of the mandibular first and second molars. Results: There were no statistically significant differences in the angulation, depth, and thickness of MBS between male and female patients. The values for the bone around the distal root of the mandibular second molar were significantly greater than the other values. The osseous characteristics were significantly better in participants aged 16-24 years. Class III patients exhibited the best osseous characteristics, with the bone depth at 6 mm being significantly different from that in Class I and Class II patients. Although values tended to be greater in patients with low angles, the difference was not statistically significant. Conclusions: MBS provides an optimal bone surface for miniscrew insertion, with better osseous characteristics at the distal root of the mandibular second molar, 4 mm from CEJ. Adolescent patients, Class III patients, and patients with a low angle exhibit the most favorable osseous characteristics in the MBS area.

Comparison of the bite force and occlusal contact area of the deviated and non-deviated sides after intraoral vertical ramus osteotomy in skeletal Class III patients with mandibular asymmetry: Two-year follow-up

  • Kwon, Hyejin;Park, Sun-Hyung;Jung, Hoi-In;Hwang, Woo-Chan;Choi, Yoon Jeong;Chung, Chooryung;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.172-181
    • /
    • 2022
  • Objective: The objectives of this study were to compare the time-dependent changes in occlusal contact area (OCA) and bite force (BF) of the deviated and non-deviated sides in mandibular prognathic patients with mandibular asymmetry before and after orthognathic surgery and investigate the factors associated with the changes in OCA and BF on each side. Methods: The sample consisted of 67 patients (33 men and 34 women; age range 15-36 years) with facial asymmetry who underwent 2-jaw orthognathic surgery. OCA and BF were taken before presurgical orthodontic treatment, within 1 month before surgery, and 1 month, 3 months, 6 months, 1 year, and 2 years after surgery. OCA and BF were measured using the Dental Prescale System. Results: The OCA and BF decreased gradually before surgery and increased after surgery on both sides. The OCA and BF were significantly greater on the deviated side than on the non-deviated side before surgery, and there was no difference after surgery. According to the linear mixed-effect model, only the changes in the mandibular plane angle had a significant effect on BF (p < 0.05). Conclusions: There was a difference in the amount of the OCA and BF between the deviated and non-deviated sides before surgery. The change in mandibular plane angle affects the change, especially on the non-deviated side, during the observation period.

Comparison of dimensional accuracy between direct-printed and thermoformed aligners

  • Koenig, Nickolas;Choi, Jin-Young;McCray, Julie;Hayes, Andrew;Schneider, Patricia;Kim, Ki Beom
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.249-257
    • /
    • 2022
  • Objective: The purpose of this study was to evaluate and compare the dimensional accuracy between thermoformed and direct-printed aligners. Methods: Three types of aligners were manufactured from the same reference standard tessellation language (STL) file: thermoformed aligners were manufactured using Zendura FLXTM (n = 12) and Essix ACETM (n = 12), and direct-printed aligners were printed using Tera HarzTM TC-85DAP 3D Printer UV Resin (n = 12). The teeth were not manipulated with any tooth-moving software in this study. The samples were sprayed with an opaque scanning spray, scanned, imported to Geomagic® Control XTM metrology software, and superimposed on the reference STL file by using the best-fit alignment algorithm. Distances between the aligner meshes and the reference STL file were measured at nine anatomical landmarks. Results: Mean absolute discrepancies in the Zendura FLXTM aligners ranged from 0.076 ± 0.057 mm to 0.260 ± 0.089 mm and those in the Essix ACETM aligners ranged from 0.188 ± 0.271 mm to 0.457 ± 0.350 mm, while in the direct-printed aligners, they ranged from 0.079 ± 0.054 mm to 0.224 ± 0.041 mm. Root mean square values, representing the overall trueness, ranged from 0.209 ± 0.094 mm for Essix ACETM, 0.188 ± 0.074 mm for Zendura FLXTM, and 0.140 ± 0.020 mm for the direct-printed aligners. Conclusions: This study showed greater trueness and precision of direct-printed aligners than thermoformed aligners.

Effectiveness of low-level laser therapy in facilitating maxillary expansion using bone-borne hyrax expander: A randomized clinical trial

  • Abdelwassie, Sara Hassan;Kaddah, Mohammed Amgad;El-Dakroury, Amr Emad;El-Boghdady, Dalia;Abd El-Ghafour, Mohamed;Seifeldin, Nouran Fouad
    • The korean journal of orthodontics
    • /
    • v.52 no.6
    • /
    • pp.399-411
    • /
    • 2022
  • Objective: The objective of this randomized clinical trial was to study the skeletal and dental effects of low-level laser therapy (LLLT) along with a miniscrew-assisted expander (Hyrax) after six months of retention. Methods: After sequence generation, concealed allocation, and implementation, 24 female patients were randomly divided (1:1) into two-groups: bone-borne rapid palatal expansion (BBE) without LLLT (n = 12) and BBE with LLLT (n = 12). Eligibility criteria included female patients aged 10-13 years old with bilateral posterior crossbites. Intraoral and extraoral photographs, cone-beam computed tomography images, and digital study models were obtained before expansion and six months after retention. The 7 mm Hyrax appliance was anchored to four palatal mini-screws, which were activated twice daily for 15 days, then locked and kept in place as a retainer. LLLT was performed in the laser group during expansion and retention, according to the guidelines provided. Results: The records of 24 patients were analyzed. According to the post-retention measurements, both groups showed a significant increase in nasal and maxillary widths and total facial height. In the laser group, the Sella-Nasion-Point A and Point A-Nasion-Point B angles and the interpremolar apical distance were significantly increased. Conclusions: Within the limitations of this study, the results suggest that the parameters and protocol of LLLT do not clinically affect the efficiency of BBE in prepubertal and pubertal patients.

Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study

  • Sewoong Oh;Youn-Kyung Choi;Sung-Hun Kim;Ching-Chang Ko;Ki Beom Kim;Yong-Il Kim
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.420-430
    • /
    • 2023
  • Objective: The purpose of this finite element method (FEM) study was to analyze the biomechanical differences and tooth displacement patterns according to the traction direction, methods, and sites for total distalization of the mandibular dentition using clear aligner treatment (CAT). Methods: A finite element analysis was performed on four FEM models using different traction methods (via a precision cut hook or button) and traction sites (mandibular canine or first premolar). A distalization force of 1.5 N was applied to the traction site by changing the direction from -30 to +30° to the occlusal plane. The initial tooth displacement and von Mises stress on the clear aligners were analyzed. Results: All CAT-based total distalization groups showed an overall trend of clockwise or counterclockwise rotation of the occlusal plane as the force direction varied. Mesiodistal tipping of individual teeth was more prominent than that of bodily movements. The initial displacement pattern of the mandibular teeth was more predominant based on the traction site than on the traction method. The elastic deformation of clear aligners is attributed to unintentional lingual tipping or extrusion of the mandibular anterior teeth. Conclusions: The initial tooth displacement can vary according to different distalization strategies for CAT-based total distalization. Discreet application and biomechanical understanding of traction sites and directions are necessary for appropriate mandibular total distalization.

Risk factors for orthodontic fixed retention failure: A retrospective controlled study

  • Kaat Verschueren;Amit Arvind Rajbhoj;Giacomo Begnoni;Guy Willems;Anna Verdonck;Maria Cadenas de Llano-Perula
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.365-373
    • /
    • 2023
  • Objective: To investigate the potential correlation between fixed orthodontic retention failure and several patient- and treatment-related factors. Methods: Patients finishing treatment with fixed appliances between 2016 and 2017 were retrospectively included in this study. Those not showing fixed retention failure were considered as control group. Patients with fixed retention failure were considered as the experimental group. Additionally, patients with failure of fixed retainers in the period of June 2019 to March 2021 were prospectively identified and included in the experimental group. The location of the first retention failure, sex, pretreatment dental occlusion, facial characteristics, posttreatment dental occlusion, treatment approach and presence of oral habits were compared between groups before and after treatment separately by using a Fisher exact test and a Mann-Whitney U test. Results: 206 patients with fixed retention failure were included, 169 in the mandibular and 74 in the maxillary jaws. Significant correlations were observed between retention failure in the mandibular jaws and mandibular arch length discrepancy (P = 0.010), post-treatment growth pattern (P = 0.041), nail biting (P < 0.001) and abnormal tongue function (P = 0.002). Retention failure in the maxillary jaws was more frequent in patients with IPR in the mandibular jaws (P = 0.005) and abnormal tongue function (P = 0.021). Conclusions: This study suggests a correlation between fixed retention failure and parafunctional habits, such as nail biting and abnormal tongue function. Prospective studies with larger study populations could further confirm these results.

Satisfaction with Dental Care in Orthodontic Patients (치열 교정환자의 치과 의료서비스 만족도에 관한 연구)

  • Kim, Jeong-suk;Yoo, Mi-seon;Ju, On-ju
    • Journal of dental hygiene science
    • /
    • v.6 no.3
    • /
    • pp.207-212
    • /
    • 2006
  • In parallel with social and economic progress, motives of patients to consult dentists have increased and diversified. An increasing number of people visit dental clinics to improve their facial appearance and masticating functions deteriorated largely due to malocclusion. There is also greater interest in and concern as well as demand for teeth alignment treatment among people. Under this situation, it is required to find and suggest ways to enhance quality and profitability of dental care in view of managerial needs for dentists to cope with changing circumstances. This study, thus, aims to measure satisfactions of orthodontics patients and to determine the elements influencing their satisfactions. For this aim, a survey was performed for 20 days from March 7th to 26th, 2005 by means of questionnaires distributed to randomly selected samples, resulting in following conclusions: 1. From comparison of satisfactions with dental service by their elements, higher satisfaction was reported from orthodontics patients in the element of dental hygienists(4.21). Least satisfaction, however, was found in the procedure for treatment and waiting hours(3.73). 2. By gender, male orthodontics patients turned out to be more satisfactory with dental service than females. In terms of intention for return visits, both male and female orthodontics patients showed higher satisfaction than non-orthodontics ones. 3. As for satisfaction with dental service by age of orthodontics and non-orthodontics patients, with regard to intention for return visit, orthodontics patients of all ages showed to have higher grade of satisfaction. 4. Regarding satisfaction with dental treatment by orthodontics and non-orthodontics patients by monthly income, Dental hygienist with intention for return visit, the higher the satisfaction of orthodontics patients. 5. In regard to satisfaction with dental treatment by education, higher satisfaction was expressed by orthodontics patients with elementary school education kept dentist, dental hygienist and internal and external environments. As a result from this study, we knew that dental service of the orthodontics patients is higher satisfaction than that of the non-orthodontics patients.

  • PDF